510(k) Report

510(k) · Cleared

Cleared

Zoe Fluid Status Monitor

K131509510(k) SpecialCleared Jun 28, 201335-day reviewClass II21 CFR 870.2770

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Noninvasive Medical Technologies, Inc. · DSB Plethysmograph, Impedance

Cleared on Jun 28, 2013 as substantially equivalent to K112830 (Noninvasive Medical Technologies, Inc., 2012) after a 35-day review. Its family tree reaches back 3 generations to 1992. 18 later devices descend from it.

Decided
Jun 28, 2013
Review
35 days
Class
Class II
Product code
DSB
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K922218 (1992). 4 ancestors in all. 18 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1999: 1 other ancestor2014: 1 descendant cleared2015: 2 descendants cleared2025: 3 descendants cleared2022: 1 descendant cleared2018: 1 descendant cleared2019: 3 descendants cleared2017: 1 descendant cleared2020: 1 descendant cleared2023: 2 descendants cleared2021: 1 descendant cleared2026: 2 descendants clearedK922218 · IQ System · Renaissance Technology, Inc. · 1992K042113 · Zoe Fluid Status Monitor · Noninvasive Medical Technologies, LLC · 2004K112830 · Zoefluid Status Monitor (Model Zoe 2B) · Noninvasive Medical Technologies, Inc. · 20121990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 5 descendants3 generations forward: 4 descendants4 generations forward: 2 descendants5 generations forward: 2 descendants6 generations forward: 1 descendant7 generations forward: 2 descendants K112830 · Zoefluid Status Monitor (Model Zoe 2B) · Noninvasive Medical Technologies, Inc. · 2012K042113 · Zoe Fluid Status Monitor · Noninvasive Medical Technologies, LLC · 2004K922218 · IQ System · Renaissance Technology, Inc. · 19920+5
  1. Root · 3 generations backK922218 IQ SystemRenaissance Technology, Inc. · 1992
  2. 2 generations backK042113 Zoe Fluid Status MonitorNoninvasive Medical Technologies, LLC · 2004
  3. 1 generation backK112830 Zoefluid Status Monitor (Model Zoe 2B)Noninvasive Medical Technologies, Inc. · 2012
  4. This deviceK131509 Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc. · 2013
  5. Descendant · cites it directly · 17 of its ownK133301 Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc. · 2014
  6. Descendant · 2 generations on · 10 of its ownK142503 Imed-Z Fluid Status MonitorIntersection Medical, Inc. · 2015
  7. Descendant · 3 generations on · 7 of its ownK172507 SOZOImpediMed Limited · 2017
  8. Descendant · 4 generations on · 4 of its ownK193410 SOZO Body Fluid AnalyzerImpediMed Limited · 2020
  9. Descendant · 5 generations on · 3 of its ownK203473 SOZOImpediMed Limited · 2021

Showing 5 of 18 descendants. See all descendants

Descendants cleared per year

2014: 12015: 22017: 12018: 12019: 32020: 12021: 12022: 12023: 22025: 32026: 2
2014high 3 (2019) · low 0 (2016)2026

Most influential descendants

Showing 5 of 18 · See all
  • K133301Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc. · 2014 · cites it directly17descendants
  • K142503Imed-Z Fluid Status MonitorIntersection Medical, Inc. · 2015 · 2 generations on10descendants
  • K172507SOZOImpediMed Limited · 2017 · 3 generations on7descendants
  • K193410SOZO Body Fluid AnalyzerImpediMed Limited · 2020 · 4 generations on4descendants
  • K203473SOZOImpediMed Limited · 2021 · 5 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K922218IQ SystemRenaissance Technology, Inc.1992—
−2K042113Zoe Fluid Status MonitorNoninvasive Medical Technologies, LLC2004—
−1K112830Zoefluid Status Monitor (Model Zoe 2B)Noninvasive Medical Technologies, Inc.2012—
0 (this device)K131509Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc.2013—
+1K133301Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc.2014—
+2K142503Imed-Z Fluid Status MonitorIntersection Medical, Inc.2015—
+3K172507SOZOImpediMed Limited2017—
+4K193410SOZO Body Fluid AnalyzerImpediMed Limited2020—
+5K203473SOZOImpediMed Limited2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201520
201710
201810
201930
202010
202110
202210
202320
202530
202620
FIG. 1 — Lineage of K131509, 1992–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DSB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DSB device

  1. #1 K232089 SOZO Proscore 14.6 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112830Zoefluid Status Monitor (Model Zoe 2B)
Summary page 1
…tially equivalent to the following currently marketed Predicate Device. Manufacturer Device Name 510-K Number Decision Date Noninvasive Medical ZOE Fluid Status Monitor K112830 11/13/2012 Technologies, Inc. Device Description: . The ZOE Fluid Status Monitor is a non-invasive; battery powered impedance mo…
Noninvasive Medical Technologies, Inc.2012—

Also cleared against K112830: 2 other devices →

What descends from it? (18)

See all 18

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133301Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc.201417
K150095ReDs Wearable SystemSensible Medical Innovations, Ltd.20151

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 8.2 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K133301 (Noninvasive Medical Technologies, Inc., 2014) has gone furthest, with 17 descendants of its own.
  • 2 other devices also cite its predicate K112830.

How does its category compare?

All DSB devices

DSB Plethysmograph, Impedance: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DSB

3in 2025

2007: 22008: 62009: 22010: 12011: 22012: 12013: 22014: 22015: 22017: 22018: 12019: 12020: 22021: 12022: 12023: 22025: 32026 (partial year): 1
2007high 6 (2008) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DSB

266in 2025

2008: 90 days median2025: 266 days median
2007high 266 (2025) · low 90 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DSB

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DSB

2in 2025

2016: 12025: 2
2007high 2 (2025) · low 0 (2007)2025

MAUDE reports naming product code DSB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
200869000
20092—00
20101—00
20112—00
20121—00
20132—00
20142—00
20152—10
20160—01
20172—00
20181—00
20191—00
20202—00
20211—00
20221—00
20232—00
20240—00
2025326602
20261—0—

What is it indicated for?

The ZOE Fluid Status Monitor is intended for patients

With fluid management problems

Taking diuretic medication

Living with Heart Failure

Living with End-stage Renal Disease

Recovering from Coronary Artery Disease related event

Suffering from Recurrent Dehydration

This device is intended for use under the direction of a physician, for the non-invasive monitoring and management of patients with fluid management problems in a variety of medically accepted clinical applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K131509: Zoe Fluid Status Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131509

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026