510(k) Report

510(k) · Cleared

Cleared

MySOZO Software version 6.1.0.1 (SW version 6.1.0.1)

K260224510(k) TraditionalCleared Aug 17, 2026203-day reviewClass II21 CFR 870.2770

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

ImpediMed Limited · DSB Plethysmograph, Impedance

Cleared on Aug 17, 2026 as substantially equivalent to K232089 (ImpediMed Limited, 2023) after a 203-day review. Its family tree reaches back 10 generations to 1992.

Decided
Aug 17, 2026
Review
203 days
Class
Class II
Product code
DSB
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K922218 (1992). 11 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 10 generations backK922218 IQ SystemRenaissance Technology, Inc. · 1992
  2. 6 generations between
  3. 3 generations backK193410 SOZO Body Fluid AnalyzerImpediMed Limited · 2020
  4. 2 generations backK203473 SOZOImpediMed Limited · 2021
  5. 1 generation backK232089 SOZO ProImpediMed Limited · 2023
  6. This deviceK260224 MySOZO Software version 6.1.0.1 (SW version 6.1.0.1)ImpediMed Limited · 2026
Show all 10 generations
  1. Root · 10 generations backK922218 IQ SystemRenaissance Technology, Inc. · 1992
  2. 9 generations backK042113 Zoe Fluid Status MonitorNoninvasive Medical Technologies, LLC · 2004
  3. 8 generations backK112830 Zoefluid Status Monitor (Model Zoe 2B)Noninvasive Medical Technologies, Inc. · 2012
  4. 7 generations backK131509 Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc. · 2013
  5. 6 generations backK133301 Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc. · 2014
  6. 5 generations backK142503 Imed-Z Fluid Status MonitorIntersection Medical, Inc. · 2015
  7. 4 generations backK172507 SOZOImpediMed Limited · 2017
  8. 3 generations backK193410 SOZO Body Fluid AnalyzerImpediMed Limited · 2020
  9. 2 generations backK203473 SOZOImpediMed Limited · 2021
  10. 1 generation backK232089 SOZO ProImpediMed Limited · 2023
  11. This deviceK260224 MySOZO Software version 6.1.0.1 (SW version 6.1.0.1)ImpediMed Limited · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K922218IQ SystemRenaissance Technology, Inc.1992—
−9K042113Zoe Fluid Status MonitorNoninvasive Medical Technologies, LLC2004—
−8K112830Zoefluid Status Monitor (Model Zoe 2B)Noninvasive Medical Technologies, Inc.2012—
−7K131509Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc.2013—
−6K133301Zoe Fluid Status MonitorNoninvasive Medical Technologies, Inc.2014—
−5K142503Imed-Z Fluid Status MonitorIntersection Medical, Inc.2015—
−4K172507SOZOImpediMed Limited2017—
−3K193410SOZO Body Fluid AnalyzerImpediMed Limited2020—
−2K203473SOZOImpediMed Limited2021—
−1K232089SOZO ProImpediMed Limited2023—
0 (this device)K260224MySOZO Software version 6.1.0.1 (SW version 6.1.0.1)ImpediMed Limited2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
FIG. 1 — Lineage of K260224, 1992–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DSB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DSB device

  1. #1 K232089 SOZO Proscore 14.6 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K232089SOZO Pro
Summary page 6
…Impedance Plethysmograph Regulatory Class: II Product Code: DSB, QJB, MNW Predicate Device: SOZO Pro® (K232089) Reference Device: SOZO (K190529) Purpose of the Traditional 510(k) Notice The purpose of the 510(k) is to cl…
ImpediMed Limited2023—
†K190529SOZOImpediMed Limited2019—

Also cleared against K232089: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 5 companies; a new generation was cleared every 2.5 years on median.
  • None of the 11 ancestors has a recall.
  • 1 other device also cites its predicate K232089.

How does its category compare?

All DSB devices

DSB Plethysmograph, Impedance: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · DSB

3in 2025

2007: 22008: 62009: 22010: 12011: 22012: 12013: 22014: 22015: 22017: 22018: 12019: 12020: 22021: 12022: 12023: 22025: 32026 (partial year): 1
2007high 6 (2008) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DSB

266in 2025

2008: 90 days median2025: 266 days median
2007high 266 (2025) · low 90 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DSB

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DSB

2in 2025

2016: 12025: 2
2007high 2 (2025) · low 0 (2007)2025

MAUDE reports naming product code DSB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
200869000
20092—00
20101—00
20112—00
20121—00
20132—00
20142—00
20152—10
20160—01
20172—00
20181—00
20191—00
20202—00
20211—00
20221—00
20232—00
20240—00
2025326602
20261—0—

What is it indicated for?

The MySOZO Software version 6.1.0.1 (SW Version 6.1.0.1) is intended for adult patients living with heart failure. This device is intended for use, under the direction of a physician, for the noninvasive monitoring of patients with fluid management problems suffering from heart failure. Data from the device should be considered in conjunction with other clinical data. For adult human patients at risk of lymphedema: A bioimpedance spectroscopy device for…

Read the full statement (382 words)

The MySOZO Software version 6.1.0.1 (SW Version 6.1.0.1) is intended for adult patients living with heart failure.

This device is intended for use, under the direction of a physician, for the noninvasive monitoring of patients with fluid management problems suffering from heart failure. Data from the device should be considered in conjunction with other clinical data.

For adult human patients at risk of lymphedema:

A bioimpedance spectroscopy device for use on adult human patients, utilizing impedance ratios that are displayed as an L-Dex ratio that supports the measurement of extracellular volume differences between the limbs and is presented to the clinician on an L-Dex scale as an aid to their clinical assessment of lymphedema.

The use of the device to obtain an L-Dex score is only indicated for patients who will have or who have had lymph nodes, from the axillary and/or pelvic regions, either removed, damaged or irradiated.

The MySOZO Software version 6.1.0.1 (SW Version 6.1.0.1) may be used as an adjunct to existing methods by aiding clinicians who are using Subjective Global Assessment (SGA) tools to assess patients at risk of protein-calorie malnutrition (PCM), and to aid in assessing patients at risk of sarcopenia, a disease of low muscle mass or muscle loss.

The MySOZO Software version 6.1.0.1 (SW Version 6.1.0.1) may be further used to estimate the following body composition parameters in humans to track clinically relevant body composition parameters over time:

• Fat mass

• Fat mass index (FMI)

• Fat-free mass

• Total body water

• Intracellular fluid

• Extracellular fluid

• Skeletal muscle mass (SMM)

• Skeletal muscle mass index (SMMI)

The following outputs are also presented:

• Body mass index (BMI)

• Basal metabolic rate (BMR; based on Mifflin – St. Jeor’s algorithm) displayed in calories per day

• Protein and mineral (also known as ‘dry lean mass’) represents the content of a body that is not fat or fluid; calculated by subtracting total body water weight from fat-free mass weight

The MySOZO Software version 6.1.0.1 (SW Version 6.1.0.1) device measures current (I), voltage (V) and phase angle (Phi), and from these values calculates resistance (R), reactance (Xc), and impedance (Z), which are used to estimate the above body composition parameters. The device/software will also display the Cole plot, subject height, weight, age and sex.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K260224: MySOZO Software version 6.1.0.1 (SW version 6.1.0.1).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K260224

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026