510(k) Report

510(k) · Cleared

Cleared

Universal Neuro 3 System

K131775510(k) TraditionalCleared Oct 17, 2013122-day reviewClass II21 CFR 882.5320

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stryker · GWO Plate, Cranioplasty, Preformed, Alterable

Cleared on Oct 17, 2013 as substantially equivalent to K112557 (Stryker, 2012) and 1 other predicate after a 122-day review. Its family tree reaches back 8 generations to 1976.

Decided
Oct 17, 2013
Review
122 days
Class
Class II
Product code
GWO
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K761228 (1976). 31 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 8 generations backK761228 Luhr Mandibular Compression-Screw SystemHowmedica Corp. · 1976
  2. 7 generations backK963739 Leibinger - Luhr Small Orthopedic Bone ScrewsHowmedica Leibinger, Inc. · 1997
  3. 6 generations backK970912 Leibinger Self-Drilling ScrewHowmedica Leibinger, Inc. · 1997
  4. 5 generations backK974785 Auto-Drive Bone ScrewOsteomed Corp. · 1998
  5. 4 generations backK023260 1.2MM Osteomed Auto-Drive Screw SystemOsteomed Corp. · 2002
  6. 3 generations backK031659 Universal Neuro SystemStryker Instruments · 2003
  7. 2 generations backK112557 Stryker Universal Neuro 3 SystemStryker · 2012
  8. 1 generation backK120352 Stryker Quikflap Sterile Procedure PackStryker · 2012 · Recalled
  9. This deviceK131775 Universal Neuro 3 SystemStryker · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K761228Luhr Mandibular Compression-Screw SystemHowmedica Corp.1976—
−7K963739Leibinger - Luhr Small Orthopedic Bone ScrewsHowmedica Leibinger, Inc.1997—
−6K970912Leibinger Self-Drilling ScrewHowmedica Leibinger, Inc.1997—
−5K974785Auto-Drive Bone ScrewOsteomed Corp.1998—
−4K0232601.2MM Osteomed Auto-Drive Screw SystemOsteomed Corp.2002—
−3K031659Universal Neuro SystemStryker Instruments2003—
−2K112557Stryker Universal Neuro 3 SystemStryker2012—
−1K120352Stryker Quikflap Sterile Procedure PackStryker201218
0 (this device)K131775Universal Neuro 3 SystemStryker2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198630
198810
199110
199310
199430
199650
199710
199830
199910
200010
200230
FIG. 1 — Lineage of K131775, 1976–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWO device

  1. #1 K261058 CraniUS Platescore 16.8 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112557Stryker Universal Neuro 3 System
Summary page 2
…Neuro 3 System Introduction: This Special 5 10O(k) is being submitted to the U.S. FDA to grant clearance to market the Stryker Universal Neuro 3 System cleared via KI 112557 with the proposed modifications. Proposed Modifications: The only modifications to the existing Stryker Universal Neuro 3 syste…
Stryker2012—
*K120352Stryker Quikflap Sterile Procedure PackStryker201218

Also cleared against K112557: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 37 years and passes through 5 companies; a new generation was cleared every 1.3 years on median.
  • 3 of the 31 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K112557.

How does its category compare?

All GWO devices

GWO Plate, Cranioplasty, Preformed, Alterable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · GWO

2in 2025

2007: 12008: 12010: 12011: 22012: 52013: 42014: 32015: 32016: 32017: 22018: 12019: 42021: 12022: 22024: 12025: 22026 (partial year): 2
2007high 5 (2012) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWO

196in 2019

2012: 133 days median2013: 249 days median2014: 109 days median2015: 210 days median2016: 125 days median2019: 196 days median
2007high 249 (2013) · low 109 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWO

2in 2015

2007: 12015: 2
2007high 2 (2015) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWO

237in 2025

2008: 32009: 22010: 72011: 12012: 52013: 72014: 112015: 182016: 182017: 472018: 412019: 142020: 252021: 412022: 532023: 722024: 1492025: 237
2007high 237 (2025) · low 0 (2007)2025

MAUDE reports naming product code GWO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—10
20081—03
20090—02
20101—07
20112—01
2012513305
2013424907
20143109011
20153210218
20163125018
20172—047
20181—041
20194196014
20200—025
20211—041
20222—053
20230—072
20241—0149
20252—0237
20262—0—

What is it indicated for?

The Stryker Universal Neuro 3 System is intended for reconstruction, stabilization and/or rigid fixation of non load-bearing bony areas subsequent to craniotomy, craniectomy and cranial fractures in adults and adolescents (age 12 and higher).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K131775: Universal Neuro 3 System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131775

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026