510(k) · Cleared
ClearedNmi Picc Iii Catheter, Nmi Hpicc Iii Catheter
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Navilyst Medical, Inc. · LJS Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
Cleared on Jul 31, 2013 as substantially equivalent to K121089 (Navilyst Medical, Inc., 2012) and 1 other predicate after a 34-day review. Its family tree reaches back 11 generations to 2000. 2 of the 52 devices in its family, counting itself, have a Class I recall. 7 later devices descend from it.
- Decided
- Jul 31, 2013
- Review
- 34 days
- Class
- Class II
- Product code
- LJS
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 11 generations to K001901 (2000). 44 ancestors in all, the oldest K830256 (1983). 7 later devices descend from it, 3 citing it directly. 2 of the 52 devices in this family, counting this one, have a Class I recall.
- Root · 11 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 7 generations between
- 3 generations backK101326 NMI ICNavilyst Medical, Inc. · 2010
- 2 generations backK111906 Xcela Hybrid Picc with Pasv Valve TechnologyNavilyst Medical, Inc. · 2011
- 1 generation backK122882 Nmi Hpicc IiiNavilyst Medical, Inc. · 2012
- This deviceK131942 Nmi Picc Iii Catheter, Nmi Hpicc Iii CatheterNavilyst Medical, Inc. · 2013
- Descendant · cites it directly · 6 of its ownK133264 Nmi Picc IiiNavilyst Medical, Inc. · 2013
- Descendant · cites it directly · 3 of its ownK140266 Nmi Picc IVNavilyst Medical, Inc. · 2014
- Descendant · 2 generations on · 1 of its ownK150527 Xcela Power Injectable PICCNavilyst Medical, Inc. · 2015
- Descendant · 2 generations on · 0 of its ownK153469 Cathtong I PICC CatheterL&Z Us, Inc. · 2016
- Descendant · 3 generations on · 0 of its ownK152409 Xcela PICC with PASV, Xcela Hybrid PICC with PASV, Xcela Power…Navilyst Medical, Inc. · 2015 · Recalled
Show all 11 generations
- Root · 11 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 10 generations backK012902 Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly…C.R. Bard, Inc. · 2001
- 9 generations backK031129 Poly Per-Q-Cath Picc Catheters; Poly RadpiccC.R. Bard, Inc. · 2003
- 8 generations backK033389 Powerpicc Catheters, Models 3175155, 3175135C.R. Bard, Inc. · 2004 · Recalled
- 7 generations backK050185 Powerhohn and Powerline CathetersC.R. Bard, Inc. · 2005
- 6 generations backK051417 6 FR FL Powerhohn and Powerline CatheterC.R. Bard, Inc. · 2005 · Recalled
- 5 generations backK051991 Powerpicc, Poly Per-Q-Cath, 6 FR TL Poly Per-Q-Cath, Power Hohn and…C.R. Bard, Inc. · 2005
- 4 generations backK061179 Powerhickman Long-Term Intravascular CatheterC.R. Bard, Inc. · 2006
- 3 generations backK101326 NMI ICNavilyst Medical, Inc. · 2010
- 2 generations backK111906 Xcela Hybrid Picc with Pasv Valve TechnologyNavilyst Medical, Inc. · 2011
- 1 generation backK122882 Nmi Hpicc IiiNavilyst Medical, Inc. · 2012
- This deviceK131942 Nmi Picc Iii Catheter, Nmi Hpicc Iii CatheterNavilyst Medical, Inc. · 2013
Showing 5 of 7 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 7 · See all- K133264Nmi Picc IiiNavilyst Medical, Inc. · 2013 · cites it directly6descendants
- K140266Nmi Picc IVNavilyst Medical, Inc. · 2014 · cites it directly3descendants
- K150527Xcela Power Injectable PICCNavilyst Medical, Inc. · 2015 · 2 generations on1descendant
- K153469Cathtong I PICC CatheterL&Z Us, Inc. · 2016 · 2 generations on0descendants
- K152409Xcela PICC with PASV, Xcela Hybrid PICC with PASV, Xcela Power Injectable PICCNavilyst Medical, Inc. · 2015 · 3 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −11 | K001901 | Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath Midline… | C.R. Bard, Inc. | 2000 | 2 |
| −10 | K012902 | Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly Per-Q-Cath… | C.R. Bard, Inc. | 2001 | — |
| −9 | K031129 | Poly Per-Q-Cath Picc Catheters; Poly Radpicc | C.R. Bard, Inc. | 2003 | — |
| −8 | K033389 | Powerpicc Catheters, Models 3175155, 3175135 | C.R. Bard, Inc. | 2004 | 1 |
| −7 | K050185 | Powerhohn and Powerline Catheters | C.R. Bard, Inc. | 2005 | — |
| −6 | K051417 | 6 FR FL Powerhohn and Powerline Catheter | C.R. Bard, Inc. | 2005 | 1 |
| −5 | K051991 | Powerpicc, Poly Per-Q-Cath, 6 FR TL Poly Per-Q-Cath, Power Hohn and Power Line | C.R. Bard, Inc. | 2005 | — |
| −4 | K061179 | Powerhickman Long-Term Intravascular Catheter | C.R. Bard, Inc. | 2006 | — |
| −3 | K101326 | NMI IC | Navilyst Medical, Inc. | 2010 | — |
| −2 | K111906 | Xcela Hybrid Picc with Pasv Valve Technology | Navilyst Medical, Inc. | 2011 | — |
| −1 | K122882 | Nmi Hpicc Iii | Navilyst Medical, Inc. | 2012 | — |
| 0 (this device) | K131942 | Nmi Picc Iii Catheter, Nmi Hpicc Iii Catheter | Navilyst Medical, Inc. | 2013 | — |
| +1 | K133264 | Nmi Picc Iii | Navilyst Medical, Inc. | 2013 | — |
| +1 | K140266 | Nmi Picc IV | Navilyst Medical, Inc. | 2014 | — |
| +2 | K150527 | Xcela Power Injectable PICC | Navilyst Medical, Inc. | 2015 | — |
| +2 | K153469 | Cathtong I PICC Catheter | L&Z Us, Inc. | 2016 | — |
| +3 | K152409 | Xcela PICC with PASV, Xcela Hybrid PICC with PASV, Xcela Power Injectable PICC | Navilyst Medical, Inc. | 2015 | 6 |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1983 | 1 | 0 |
| 1986 | 1 | 1 |
| 1991 | 1 | 0 |
| 1996 | 1 | 0 |
| 1997 | 2 | 0 |
| 1999 | 2 | 0 |
| 2000 | 2 | 1 |
| 2001 | 4 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 4 | 0 |
| 2005 | 3 | 0 |
| 2006 | 3 | 0 |
| 2007 | 2 | 0 |
| 2008 | 1 | 0 |
| 2009 | 3 | 0 |
| 2012 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 4 | 0 |
| 2016 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LJS device
- #1 K241910 Neonav ECG Tip Location Systemscore 18.0 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
What descends from it? (7)
3 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (2 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K993691Arrowg +Ard Blue Plus Antimicrobial Multi-Lumen Central Venous CatheterArrow Intl., Inc. · 2000 · 5 generations back · ◆ in the 2000 ancestors bar of FIG. 11 Class I recall
- K862056[Central Venous][Multi-Lumen] Catheter W/Flex TipArrow Intl., Inc. · 1986 · 6 generations back · ◆ in the 1986 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 13 years and passes through 2 companies; a new generation was cleared every 11 months on median.
- 15 of the 44 ancestors have a recall of any class; 2 have a Class I recall.
- Of its descendants, K133264 (Navilyst Medical, Inc., 2013) has gone furthest, with 6 descendants of its own.
- 5 other devices also cite its predicate K121089.
How does its category compare?
All LJS devicesLJS Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · LJS
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LJS
171in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LJS
5in 2023
Class I (3 since 2007) Class II/III not classified
Adverse event reports per year · LJS
4,372in 2025
MAUDE reports naming product code LJS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 92 | 0 | 392 |
| 2008 | 4 | 97 | 1 | 369 |
| 2009 | 16 | 70 | 1 | 379 |
| 2010 | 9 | 114 | 12 | 495 |
| 2011 | 6 | 55 | 4 | 696 |
| 2012 | 14 | 77 | 40 | 564 |
| 2013 | 14 | 31 | 0 | 680 |
| 2014 | 8 | 47 | 15 | 842 |
| 2015 | 7 | 71 | 2 | 1,306 |
| 2016 | 9 | 128 | 18 | 1,123 |
| 2017 | 7 | 101 | 9 | 2,100 |
| 2018 | 10 | 148 | 3 | 2,324 |
| 2019 | 0 | — | 0 | 2,052 |
| 2020 | 2 | — | 0 | 2,539 |
| 2021 | 3 | 284 | 1 | 3,084 |
| 2022 | 3 | 177 | 0 | 3,256 |
| 2023 | 4 | 47 | 5 (2) | 2,799 |
| 2024 | 1 | — | 0 | 4,243 |
| 2025 | 8 | 171 | 0 | 4,372 |
| 2026 | 2 | — | 8 (1) | — |
What is it indicated for?
The NMI PICC III is indicated for short- or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients, the sampling of blood, for central venous pressure monitoring and for power injection of contrast media. Maximum Power Injection Flow Rate Description — Flow Rate 4F Single Lumen - 55cm length — 3.5 mL/sec 5F Single Lumen - 55cm length — 5…
Read the full statement (269 words)
The NMI PICC III is indicated for short- or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients, the sampling of blood, for central venous pressure monitoring and for power injection of contrast media.
Maximum Power Injection Flow Rate
Description — Flow Rate
4F Single Lumen - 55cm length — 3.5 mL/sec
5F Single Lumen - 55cm length — 5 mL/sec
5F Dual Lumen - 55 cm length — 4 mL/sec
6F Dual Lumen - 55cm length — 5 mL/sec
The NMI PICC III with PASV Valve Technology is indicated for short- or long-term access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients, the sampling of blood, and for power injection of contrast media.
Maximum Power Injection Flow Rate
Description — Flow Rate
3F Single Lumen - 55cm length — 1 mL/sec
4F Single Lumen - 55cm length — 3.5 mL/sec
5F Single Lumen - 55cm length — 5 mL/sec
5F Dual Lumen - 55cm length — 4 mL/sec
6F Dual Lumen - 55cm length — 5 mL/sec
6F Triple Lumen - 55cm length — 6 mL/sec
The NMI HPICC III is indicated for short- or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients, the sampling of blood, and for power injection of contrast media. Non-valved lumens are indicated for central venous pressure monitoring. The maximum power injection flow rate for the NMI HPICC III is 6 mL/sec.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K131942 · printed Nov 6, 2026
Cite this page
510(k) Report. “K131942: Nmi Picc Iii Catheter, Nmi Hpicc Iii Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131942
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026