510(k) Report

510(k) · Cleared

Cleared

Bovine Pericardium Suturable Dural Graft, Tutopatch DM Graft, Tutoplast Bovine Pericardium DM

K132850510(k) TraditionalCleared Mar 31, 2014201-day reviewClass II21 CFR 882.5910

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rti Surgical, Inc. · GXQ Dura Substitute

Cleared on Mar 31, 2014 as substantially equivalent to K950956 (Bio-Vascular, Inc., 1995) and 3 other predicates after a 201-day review. Its family tree reaches back 5 generations to 1995.

Decided
Mar 31, 2014
Review
201 days
Class
Class II
Product code
GXQ
Recalls
None
Predicates
4

Its longest line of descent runs back 5 generations to K950956 (1995). 9 ancestors in all, the oldest K910555 (1992). No later device cites it as a predicate yet.

  1. Root · 5 generations backK950956 Dura-Guard Dural Repair Patch, Dura-Guard Dura SubstituteBio-Vascular, Inc. · 1995
  2. 4 generations backK973706 Dura-Guard-Dural Repair PatchBio-Vascular, Inc. · 1997
  3. 3 generations backK982180 Duragen Dural Graft MatrixIntegra Lifesciences Corp. · 1999 · Recalled
  4. 2 generations backK040888 Duramatrix Collagen Dura Substitute MembraneCollagen Matrix, Inc. · 2004
  5. 1 generation backK061487 Duramatrix Collagen Dura Substitute Membrane - Onlay and SuturableCollagen Matrix, Inc. · 2006 · Recalled
  6. This deviceK132850 Bovine Pericardium Suturable Dural Graft, Tutopatch DM Graft…Rti Surgical, Inc. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K950956Dura-Guard Dural Repair Patch, Dura-Guard Dura SubstituteBio-Vascular, Inc.1995—
−4K973706Dura-Guard-Dural Repair PatchBio-Vascular, Inc.1997—
−3K982180Duragen Dural Graft MatrixIntegra Lifesciences Corp.19991
−2K040888Duramatrix Collagen Dura Substitute MembraneCollagen Matrix, Inc.2004—
−1K061487Duramatrix Collagen Dura Substitute Membrane - Onlay and SuturableCollagen Matrix, Inc.20062
0 (this device)K132850Bovine Pericardium Suturable Dural Graft, Tutopatch DM Graft, Tutoplast Bovine…Rti Surgical, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
199510
199710
199810
FIG. 1 — Lineage of K132850, 1995–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GXQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GXQ device

  1. #1 K251191 Collagen Dura Regeneration Membrane - Repairscore 12.2 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K950956Dura-Guard Dural Repair Patch, Dura-Guard Dura Substitute
Summary page 1
…d Code: Dura substitute (21 CFR 882.5910, product code GXQ) Substantial Equivalence: The proposed device is substantially equivalent to the predicate device Dura-Guard (K950956 and K982282) and Lyoplant (K970851) in intended use, material, design and function. The proposed device issubstantially equivalen…
Bio-Vascular, Inc.1995—
*K982282Dura-Guard - Dural Repair Patch
Summary page 1
…substitute (21 CFR 882.5910, product code GXQ) Substantial Equivalence: The proposed device is substantially equivalent to the predicate device Dura-Guard (K950956 and K982282) and Lyoplant (K970851) in intended use, material, design and function. The proposed device issubstantially equivalent to the pre…
Bio-Vascular, Inc.19981
*K970851Lyoplant Dura Substitute (Various)
Summary page 1
….5910, product code GXQ) Substantial Equivalence: The proposed device is substantially equivalent to the predicate device Dura-Guard (K950956 and K982282) and Lyoplant (K970851) in intended use, material, design and function. The proposed device issubstantially equivalent to the predicate device Dura-Matr…
Aesculap, Inc.1997—
*K061487Duramatrix Collagen Dura Substitute Membrane - Onlay and Suturable
Summary page 1
…6 and K982282) and Lyoplant (K970851) in intended use, material, design and function. The proposed device issubstantially equivalent to the predicate device Dura-Matrix (K061487) in intended use, design and function. The proposed device is similar in design, function, materials and processing to reference…
Collagen Matrix, Inc.20062
†K991296TutopatchTutogen Medical U.S., Inc.2000—
†K073097Tutodent Dental MembraneTutogen Medical U.S., Inc.2008—
†K081538Tutopatch, TutomeshRti Biologics, Inc.2008—
†K091142Tutopatch, Tutomesh, Models 68350, 68351, 68352, 68353, 68354, 68355, 68356, 68357, 68358Rti Biologics, Inc.2009—
†K910555Tutoplast DuraPfrimmer-Viggo GmbH & Co.1992—

Also cleared against K950956: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 2.6 years on median.
  • 3 of the 9 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K950956.

How does its category compare?

All GXQ devices

GXQ Dura Substitute: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · GXQ

2in 2025

2007: 22010: 12012: 22013: 32014: 12015: 32016: 32017: 22019: 12022: 12023: 12025: 2
2007high 3 (2013) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GXQ

94in 2016

2013: 181 days median2015: 214 days median2016: 94 days median
2007high 214 (2015) · low 94 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GXQ

2in 2024

2010: 62013: 12021: 22024: 2
2007high 6 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GXQ

61in 2025

2007: 552008: 432009: 462010: 362011: 312012: 382013: 722014: 182015: 622016: 582017: 572018: 942019: 632020: 1142021: 762022: 592023: 1092024: 552025: 61
2007high 114 (2020) · low 18 (2014)2025

MAUDE reports naming product code GXQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—055
20080—043
20090—046
20101—636
20110—031
20122—038
20133181172
20141—018
20153214062
2016394058
20172—057
20180—094
20191—063
20200—0114
20210—276
20221—059
20231—0109
20240—255
20252—061
20260—0—

What is it indicated for?

The device is indicated as a dura substitute for the repair of dura mater.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K132850: Bovine Pericardium Suturable Dural Graft, Tutopatch DM Graft, Tutoplast Bovine Pericardium DM.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K132850

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026