Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO Syringe

K132928510(k) SpecialCleared Jan 23, 2014127-day reviewClass II21 CFR 870.1650Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medrad, Inc. / Bayer Medical Care, Inc. · DXT Injector And Syringe, Angiographic

Cleared on Jan 23, 2014 as substantially equivalent to K113133 (Medrad, Inc., 2011) and 1 other predicate after a 127-day review. Its family tree reaches back 3 generations to 1990. 2 later devices descend from it. It has been recalled 2 times.

Decided
Jan 23, 2014
Review
127 days
Class
Class II
Product code
DXT
Recalls
2
Predicates
2

Its longest line of descent runs back 3 generations to K903390 (1990). 4 ancestors in all. 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2019: 1 descendant cleared2018: 1 descendant clearedK903390 · Medrad Mark V-Plus Injector · Medrad, Inc. · 1990 · recalled×2: 2 generations cleared close together, K112086 (2011), K113133 (2011) 1990200020102020
  1. Root · 3 generations backK903390 Medrad Mark V-Plus InjectorMedrad, Inc. · 1990 · Recalled
  2. 2 generations backK112086 Medrad Mark 7 Arterion (Pedestal System / Table Mount System)…Medrad, Inc. · 2011 · Recalled
  3. 1 generation backK113133 Medrad Mark 7 Arterion (Pedestal System), (Table Mount System)…Medrad, Inc. · 2011
  4. This deviceK132928 Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO SyringeMedrad, Inc. / Bayer Medical Care, Inc. · 2014
  5. Descendant · cites it directly · 0 of its ownK193028 MEDRAD Mark 7 Arterion Injection SystemBayer Medical Care, Inc. · 2019
  6. Descendant · cites it directly · 0 of its ownK173450 PRESS DUO elite, PRESS DUO elite AGNemoto Kyorindo Co., Ltd. · 2018

Most influential descendants

Showing 2 of 2 · See all
  • K193028MEDRAD Mark 7 Arterion Injection SystemBayer Medical Care, Inc. · 2019 · cites it directly0descendants
  • K173450PRESS DUO elite, PRESS DUO elite AGNemoto Kyorindo Co., Ltd. · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K903390Medrad Mark V-Plus InjectorMedrad, Inc.19901
−2K112086Medrad Mark 7 Arterion (Pedestal System / Table Mount System), Medrad Mark 7…Medrad, Inc.20111
−1K113133Medrad Mark 7 Arterion (Pedestal System), (Table Mount System), Medrad Mark 7…Medrad, Inc.2011—
0 (this device)K132928Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO SyringeMedrad, Inc. / Bayer Medical Care, Inc.2014—
+1K193028MEDRAD Mark 7 Arterion Injection SystemBayer Medical Care, Inc.2019—
+1K173450PRESS DUO elite, PRESS DUO elite AGNemoto Kyorindo Co., Ltd.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
FIG. 1 — Lineage of K132928, 1990–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXT device

  1. #1 K253048 High Pressure Syringe; Pressure Connecting…score 13.6 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K113133Medrad Mark 7 Arterion (Pedestal System), (Table Mount System), Medrad Mark 7 Arterion…
Summary page 1
…following devices: MEDRAD Mark 7 Arterion Injection System o K113133, December 15, 2011 to K1 12086, October 14, 2011 MIEDRAD, Inc. - MEDRA…
Medrad, Inc.2011—
*K112086Medrad Mark 7 Arterion (Pedestal System / Table Mount System), Medrad Mark 7 Arterion…
Summary page 1
…MEDRAD Mark 7 Arterion Injection System o K113133, December 15, 2011 to K1 12086, October 14, 2011 MIEDRAD, Inc. - MEDRAD ma1 7 Arloo injection System 510(k) Summnary Page 1 of$ === Pag…
Medrad, Inc.20111

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K193028MEDRAD Mark 7 Arterion Injection SystemBayer Medical Care, Inc.20190
K173450PRESS DUO elite, PRESS DUO elite AGNemoto Kyorindo Co., Ltd.20180

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 14, 2021Class IIZ-0199-2022Packaging process controlLabeling error: MEDRAD Mark 7 Arterion Injection System Syringes (ART 700 SYR) labeled as Twist & Go Syringes (TAG 150 SYR)
Aug 4, 2015Class IIZ-2775-2015Software designSoftware Version SW 005.006_SH, resulted in the removal of purge enforcement from traditional New-Case, Power Up and Syringe Change use cases while the injector head is in the upright position.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 2 companies; a new generation was cleared every 2.1 years on median.
  • 3 of the 4 ancestors have a recall of any class.
  • Of its descendants, K193028 (Bayer Medical Care, Inc., 2019) has gone furthest, with 0 descendants of its own.

How does its category compare?

All DXT devices

DXT Injector And Syringe, Angiographic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · DXT

1in 2025

2007: 32008: 22009: 62010: 12011: 42013: 22014: 62015: 72016: 82017: 72018: 92019: 42020: 32021: 12023: 12024: 42025: 12026 (partial year): 7
2007high 9 (2018) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXT

138in 2024

2007: 182 days median2009: 137 days median2011: 69 days median2014: 144 days median2015: 153 days median2016: 172 days median2017: 183 days median2018: 93 days median2019: 96 days median2020: 154 days median2024: 138 days median2026 (partial year): 264 days median
2007high 264 (2026) · low 69 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXT

10in 2024

2007: 42008: 32009: 72010: 32011: 32012: 72015: 12018: 22020: 12021: 12023: 22024: 102026 (partial year): 6
2007high 10 (2024) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXT

97in 2025

2007: 1072008: 1682009: 1882010: 1242011: 1332012: 1352013: 1412014: 972015: 1352016: 1522017: 1282018: 1292019: 1212020: 932021: 1322022: 1112023: 1172024: 1182025: 97
2007high 188 (2009) · low 93 (2020)2025

MAUDE reports naming product code DXT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731824107
20082—3168
200961377188
20101—3124
20114693133
20120—7135
20132—0141
20146144097
201571531135
201681720152
201771830128
20189932129
20194960121
20203154193
20211—1132
20220—0111
20231—2117
2024413810118
20251—097
202672646—

What is it indicated for?

The MEDRAD Mark 7 Arterion Injection System is intended to be used specifically for the purposes of injecting contrast medium and common flushing solutions into humans for angiographic studies.

The MEDRAD Mark 7 Arterion Syringe, Quick Fill Tube and other MEDRAD supplied disposables are specifically intended for single use only with the MEDRAD Mark 7 Arterion Injection System for angiographic studies.

The MEDRAD Twist & Go Syringe, Quick Fill Tube and other MEDRAD supplied disposables are specifically intended for single use only with the MEDRAD Mark 7 Arterion Injection System for angiographic studies.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K132928: Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO Syringe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K132928

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026