MEDRAD Mark 7 Arterion Injection System

K193028510(k) SpecialCleared Dec 5, 201936-day reviewClass II21 CFR 870.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bayer Medical Care, Inc. · DXT Injector And Syringe, Angiographic

Cleared on Dec 5, 2019 as substantially equivalent to K132928 (Medrad, Inc. / Bayer Medical Care, Inc., 2014) after a 36-day review. Its family tree reaches back 4 generations to 1990.

Decided
Dec 5, 2019
Review
36 days
Class
Class II
Product code
DXT
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K903390 (1990). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK903390 Medrad Mark V-Plus InjectorMedrad, Inc. · 1990 · Recalled
  2. 3 generations backK112086 Medrad Mark 7 Arterion (Pedestal System / Table Mount System)…Medrad, Inc. · 2011 · Recalled
  3. 2 generations backK113133 Medrad Mark 7 Arterion (Pedestal System), (Table Mount System)…Medrad, Inc. · 2011
  4. 1 generation backK132928 Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO SyringeMedrad, Inc. / Bayer Medical Care, Inc. · 2014 · Recalled
  5. This deviceK193028 MEDRAD Mark 7 Arterion Injection SystemBayer Medical Care, Inc. · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K903390Medrad Mark V-Plus InjectorMedrad, Inc.19901
−3K112086Medrad Mark 7 Arterion (Pedestal System / Table Mount System), Medrad Mark 7…Medrad, Inc.20111
−2K113133Medrad Mark 7 Arterion (Pedestal System), (Table Mount System), Medrad Mark 7…Medrad, Inc.2011—
−1K132928Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO SyringeMedrad, Inc. / Bayer Medical Care, Inc.20142
0 (this device)K193028MEDRAD Mark 7 Arterion Injection SystemBayer Medical Care, Inc.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510
FIG. 1 — Lineage of K193028, 1990–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXT device

  1. #1 K253048 High Pressure Syringe; Pressure Connecting…score 13.6 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K132928Medrad Mark 7 Arterion Injection System / Syringe, Twist & GO Syringe
Summary page 4
…equivalent to the following device: MEDRAD® Mark 7 Arterion Injection System, K132928. Bayer Medical Care Inc. MEDRAD Mark 7 Arterion Injection System 510(k) Summary Page 1 of 6…
Medrad, Inc. / Bayer Medical Care, Inc.20142

Also cleared against K132928: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 3 companies; a new generation was cleared every 5.9 years on median.
  • 4 of the 5 ancestors have a recall of any class.
  • 1 other device also cites its predicate K132928.

How does its category compare?

All DXT devices

DXT Injector And Syringe, Angiographic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · DXT

1in 2025

2007: 32008: 22009: 62010: 12011: 42013: 22014: 62015: 72016: 82017: 72018: 92019: 42020: 32021: 12023: 12024: 42025: 12026 (partial year): 7
2007high 9 (2018) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXT

138in 2024

2007: 182 days median2009: 137 days median2011: 69 days median2014: 144 days median2015: 153 days median2016: 172 days median2017: 183 days median2018: 93 days median2019: 96 days median2020: 154 days median2024: 138 days median2026 (partial year): 264 days median
2007high 264 (2026) · low 69 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXT

10in 2024

2007: 42008: 32009: 72010: 32011: 32012: 72015: 12018: 22020: 12021: 12023: 22024: 102026 (partial year): 6
2007high 10 (2024) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXT

97in 2025

2007: 1072008: 1682009: 1882010: 1242011: 1332012: 1352013: 1412014: 972015: 1352016: 1522017: 1282018: 1292019: 1212020: 932021: 1322022: 1112023: 1172024: 1182025: 97
2007high 188 (2009) · low 93 (2020)2025

MAUDE reports naming product code DXT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731824107
20082—3168
200961377188
20101—3124
20114693133
20120—7135
20132—0141
20146144097
201571531135
201681720152
201771830128
20189932129
20194960121
20203154193
20211—1132
20220—0111
20231—2117
2024413810118
20251—097
202672646—

What is it indicated for?

MEDRAD® Mark 7 Arterion Injection System

The MEDRAD® Mark 7 Arterion Injection System is indicated to be used specifically for the purposes of injecting contrast medium and common flushing solutions into humans for angiographic studies.

Imaging System Interface (ISI)

The ISI option is indicated for the specific purpose of allowing a MEDRAD® Mark 7 Arterion Injection System to interface with an angiography imaging system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K193028: MEDRAD Mark 7 Arterion Injection System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K193028

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026