Hemoglobin A1c Assay, Hemoglobin A1c Calibrators, Hemoglobin A1c Controls

K140654510(k) TraditionalCleared May 22, 2015434-day reviewClass II21 CFR 862.1373Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Laboratories · PDJ Hemoglobin A1c Test System

Cleared on May 22, 2015 as substantially equivalent to K130255 (Abbott Laboratories, 2014) after a 434-day review. Its family tree reaches back 3 generations to 1994. It has been recalled 2 times.

Decided
May 22, 2015
Review
434 days
Class
Class II
Product code
PDJ
Recalls
2
Predicates
1

Its longest line of descent runs back 3 generations to K934070 (1994). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK934070 Tina-Quant Hemoglobin A1CBoehringer Mannheim Corp. · 1994
  2. 2 generations backK052101 C.F.a.S. (Calibrator for Automated Systems) HBA1CRoche Diagnostics · 2005
  3. 1 generation backK130255 Hemoglobin A1C, Hemoglobin A1C Calibrators, Hemoglobin A1C ControlsAbbott Laboratories · 2014 · Recalled
  4. This deviceK140654 Hemoglobin A1c Assay, Hemoglobin A1c Calibrators, Hemoglobin A1c…Abbott Laboratories · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K934070Tina-Quant Hemoglobin A1CBoehringer Mannheim Corp.1994—
−2K052101C.F.a.S. (Calibrator for Automated Systems) HBA1CRoche Diagnostics2005—
−1K130255Hemoglobin A1C, Hemoglobin A1C Calibrators, Hemoglobin A1C ControlsAbbott Laboratories20143
0 (this device)K140654Hemoglobin A1c Assay, Hemoglobin A1c Calibrators, Hemoglobin A1c ControlsAbbott Laboratories2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201010
201310
FIG. 1 — Lineage of K140654, 1994–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PDJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PDJ device

  1. #1 K252749 Medconn 8K Glycated Hemoglobin Test Systemscore 11.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130255Hemoglobin A1C, Hemoglobin A1C Calibrators, Hemoglobin A1C Controls
Summary page 5
…ication: Class II Product Code: JJX Panel Classification: Clinical Chemistry 3. Predicate Device ARCHITECT Hemoglobin A1c Reagents, Calibrators, and Controls (k130255) Note: The candidate device consists of the same reagents as the predicate device, and utilizes the same calibrators and c…
Abbott Laboratories20143

Also cleared against K130255: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 9, 2022Class IIZ-1454-2022Under Investigation by firmThere is a potential for falsely elevated Hemoglobin %A1c and Hemoglobin A1c results to be generated using the ARCHITECT and Alinity c Hemoglobin A1c assay.
May 22, 2019Class IIZ-1688-2020Under Investigation by firmCalibrator level 2 bottle may have been manufactured incorrectly for a portion of the lot. The manufacturer observed no impact to assay performance between the HbA1c concentration range of 5.33% to 6.87%. However, outside of this range, a…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 8.5 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K130255.

How does its category compare?

All PDJ devices

PDJ Hemoglobin A1c Test System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · PDJ

2in 2025

2013: 22014: 22015: 42016: 22017: 32018: 52019: 12020: 12021: 22024: 12025: 22026 (partial year): 2
2007high 5 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PDJ

203in 2018

2015: 234 days median2017: 173 days median2018: 203 days median
2007high 234 (2015) · low 173 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PDJ

1in 2022

2016: 12022: 12026 (partial year): 1
2007high 1 (2016) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PDJ

42in 2025

2013: 92014: 102015: 22017: 12020: 52021: 62022: 192023: 162024: 472025: 42
2007high 47 (2024) · low 0 (2007)2025

MAUDE reports naming product code PDJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20132—09
20142—010
2015423402
20162—10
2017317301
2018520300
20191—00
20201—05
20212—06
20220—119
20230—016
20241—047
20252—042
20262—1—

What is it indicated for?

The Hemoglobin A1c assay is used in clinical laboratories for the quantitative in vitro measurement of percent hemoglobin A1c (NGSP) or HbA1c fraction mmol/mol (IFCC) in human whole blood and hemolysate on the ARCHITECT c 4000 System. Hemoglobin A1c measurements are used as an aid in the diagnosis of diabetes mellitus, as an aid to identify patients who may be at risk for developing diabetes mellitus, and for the monitoring of long-term blood glucose…

Read the full statement (131 words)

The Hemoglobin A1c assay is used in clinical laboratories for the quantitative in vitro measurement of percent hemoglobin A1c (NGSP) or HbA1c fraction mmol/mol (IFCC) in human whole blood and hemolysate on the ARCHITECT c 4000 System.

Hemoglobin A1c measurements are used as an aid in the diagnosis of diabetes mellitus, as an aid to identify patients who may be at risk for developing diabetes mellitus, and for the monitoring of long-term blood glucose control in individuals with diabetes mellitus.

The Hemoglobin A1c Calibrators are for use in the calibration of the Hemoglobin A1c assay on the ARCHITECT c 4000 System.

The Hemoglobin A1c Controls are used for the estimation of test precision and the detection of systematic analytical deviations of the Hemoglobin A1c assay on the ARCHITECT c 4000 System.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140654: Hemoglobin A1c Assay, Hemoglobin A1c Calibrators, Hemoglobin A1c Controls.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140654

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026