Vdrive with V-Loop/ Vdrive Duo

K140804510(k) TraditionalCleared Sep 3, 2014156-day reviewClass II21 CFR 870.1290

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stereotaxis, Inc. · DXX System, Catheter Control, Steerable

Cleared on Sep 3, 2014 as substantially equivalent to K122659 (Stereotaxis, Inc., 2013) after a 156-day review. Its family tree reaches back 2 generations to 2007. 2 later devices descend from it.

Decided
Sep 3, 2014
Review
156 days
Class
Class II
Product code
DXX
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K071029 (2007). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared2015: 1 descendant clearedReference device: K133396 · Vdrive with V-Sono · Stereotaxis, Inc. · 2014K071029 · Cardiodrive Catheter Advancement System (Cas) · Stereotaxis, Inc. · 2007K122659 · Vdrive W/V-Sono · Stereotaxis, Inc. · 201320052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K122659 · Vdrive W/V-Sono · Stereotaxis, Inc. · 2013K071029 · Cardiodrive Catheter Advancement System (Cas) · Stereotaxis, Inc. · 20070
  1. Root · 2 generations backK071029 Cardiodrive Catheter Advancement System (Cas)Stereotaxis, Inc. · 2007
  2. 1 generation backK122659 Vdrive W/V-SonoStereotaxis, Inc. · 2013
  3. This deviceK140804 Vdrive with V-Loop/ Vdrive DuoStereotaxis, Inc. · 2014
  4. Descendant · cites it directly · 1 of its ownK141530 Vdrive System/ Vdrive Duo/ Vdrive with V-CasStereotaxis, Inc. · 2014
  5. Descendant · 2 generations on · 0 of its ownK150312 Vdrive system, Vdrive Duo, Vdrive with V-SonoStereotaxis, Inc. · 2015

Most influential descendants

Showing 2 of 2 · See all
  • K141530Vdrive System/ Vdrive Duo/ Vdrive with V-CasStereotaxis, Inc. · 2014 · cites it directly1descendant
  • K150312Vdrive system, Vdrive Duo, Vdrive with V-SonoStereotaxis, Inc. · 2015 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K071029Cardiodrive Catheter Advancement System (Cas)Stereotaxis, Inc.2007—
−1K122659Vdrive W/V-SonoStereotaxis, Inc.2013—
0 (this device)K140804Vdrive with V-Loop/ Vdrive DuoStereotaxis, Inc.2014—
+1K141530Vdrive System/ Vdrive Duo/ Vdrive with V-CasStereotaxis, Inc.2014—
+2K150312Vdrive system, Vdrive Duo, Vdrive with V-SonoStereotaxis, Inc.2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201510
FIG. 1 — Lineage of K140804, 2007–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXX device

  1. #1 K251792 Stereotaxis GenesisX RMN with Navigant ™…score 13.9 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K122659Vdrive W/V-Sono
Summary page 5
…tion Panel: Cardiovascular Currently Marketed Substantially Equivalent Device: Vdrive™ with V-Sono™ (K122659) Device The Vdrive™ with V-Loop™ is provides a remote method of controlling the description advanc…
Stereotaxis, Inc.2013—
†K133396Vdrive with V-SonoStereotaxis, Inc.2014—

Also cleared against K122659: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K141530Vdrive System/ Vdrive Duo/ Vdrive with V-CasStereotaxis, Inc.20141

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 5.9 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K141530 (Stereotaxis, Inc., 2014) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K122659.

How does its category compare?

All DXX devices

DXX System, Catheter Control, Steerable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · DXX

2in 2025

2007: 22008: 12009: 22010: 12012: 42013: 12014: 42015: 42016: 22018: 32020: 12022: 12025: 22026 (partial year): 1
2007high 4 (2012) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXX

76in 2018

2012: 155 days median2014: 104 days median2015: 156 days median2018: 76 days median
2007high 156 (2015) · low 76 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXX

1in 2014

2009: 12014: 1
2007high 1 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXX

1in 2024

2007: 12009: 22011: 62012: 22013: 12014: 142015: 22016: 252017: 32018: 92019: 92020: 42021: 52022: 12024: 1
2007high 25 (2016) · low 0 (2008)2025

MAUDE reports naming product code DXX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—01
20081—00
20092—12
20101—00
20110—06
2012415502
20131—01
20144104114
2015415602
20162—025
20170—03
201837609
20190—09
20201—04
20210—05
20221—01
20230—00
20240—01
20252—00
20261—0—

What is it indicated for?

The Vdrive™ system is intended to stabilize, navigate and remotely control: • compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance of electrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive™ system. • compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during the performance of cardiac procedure when…

Read the full statement (247 words)

The Vdrive™ system is intended to stabilize, navigate and remotely control:

• compatible loop (circular) mapping catheters to facilitate movement of the catheter during the performance of electrophysiological procedures when used in conjunction with the V-Loop™ disposable sets in the Vdrive™ system.

• compatible Intracardiac Echocardiography (ICE) catheters to facilitate visualization of cardiac structure during the performance of cardiac procedure when used in conjunction with the V-Sono™ disposable sets in the Vdrive™ system.

The Vdrive™ with V-Loop™ disposable is indicated to remotely control the advancement, retraction, rotation, tip deflection and loop size of compatible loop catheters inserted across the septum into the left atrium using conventional procedures. Compatible catheters at this time include Biosense Webster Lasso 2515 and Lasso 2515 NAV Circular Mapping Catheters. Other models of loop catheters have not been tested with the Vdrive™ system.

The Vdrive™ with V-Sono™ disposable is indicated for remotely controlling the advancement, retraction, rotation and anterior-posterior deflection of compatible ultrasound catheters inserted into the right atrium. Compatible catheters at this time include Biosense Webster, Inc. Soundstar™ 3D Ultrasound Catheters and Acuson AcuNav™ Ultrasound Catheters. Other models of ICE catheters have not been tested with the Vdrive™ system.

The Vdrive Duo™ is an optional accessory intended for remotely controlling the Vdrive™ system when one arm of the device is equipped with a V-Loop™ disposable set and the other arm is equipped with the V-Sono™ disposable set. During the procedure, the Vdrive Duo™ allows selection between the disposable sets (V-Loop™ or V-Sono™).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140804: Vdrive with V-Loop/ Vdrive Duo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K140804

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026