510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Dimension Vista Free Thyroxine Flex Reagent Cartridge, FT4, Dimension Vista Thyroid Stimulating Hormone Flex Reagent

K140859510(k) TraditionalCleared Nov 26, 2014237-day reviewClass II21 CFR 862.1695Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics, Inc. · CEC Radioimmunoassay, Free Thyroxine

Cleared on Nov 26, 2014 as substantially equivalent to K053531 (Dade Behring, Inc., 2006) and 1 other predicate after a 237-day review. Its family tree reaches back 2 generations to 1997. It has been recalled 3 times.

Decided
Nov 26, 2014
Review
237 days
Class
Class II
Product code
CEC
Recalls
3
Predicates
2

Its longest line of descent runs back 2 generations to K970389 (1997). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2006: 1 other ancestorK970389 · Thyroid Calibrator · Dade Chemistry Systems, Inc. · 1997K053531 · Dimension Vista Free Thyroxine Flex Reagent Cartridge and Loci 1 Calibrator · Dade Behring, Inc. · 200619952000200520102015
  1. Root · 2 generations backK970389 Thyroid CalibratorDade Chemistry Systems, Inc. · 1997
  2. 1 generation backK053531 Dimension Vista Free Thyroxine Flex Reagent Cartridge and Loci 1…Dade Behring, Inc. · 2006
  3. This deviceK140859 Dimension Vista Free Thyroxine Flex Reagent Cartridge, FT4…Siemens Healthcare Diagnostics, Inc. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K970389Thyroid CalibratorDade Chemistry Systems, Inc.1997—
−1K053531Dimension Vista Free Thyroxine Flex Reagent Cartridge and Loci 1 CalibratorDade Behring, Inc.2006—
0 (this device)K140859Dimension Vista Free Thyroxine Flex Reagent Cartridge, FT4, Dimension Vista…Siemens Healthcare Diagnostics, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200610
FIG. 1 — Lineage of K140859, 1997–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CEC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CEC device

  1. #1 K240273 Access Free T4score 7.0 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053531Dimension Vista Free Thyroxine Flex Reagent Cartridge and Loci 1 Calibrator
Summary page 6
…Hormone Flex® reagent cartridge, TSH Subject Device Same (As above) Same (As above) Predicate 510(k) K053531 K060090 5. Substantial Equivalence Information The following table demonstrates sub…
Dade Behring, Inc.2006—
*K060090Dimension Vista Thyroid Stimulating Hormone Flex Reagent Cartridge
Summary page 6
…ubject Device Same (As above) Same (As above) Predicate 510(k) K053531 K060090 5. Substantial Equivalence Information The following table demonstrates substantial equivalence between the predica…
Dade Behring, Inc.20061

Also cleared against K053531: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 2, 2018Class IIZ-1673-2018Error in labelingThe concentrations for biotin listed in the non-interfering substances section of the instructions for use for the Dimension TSHL, Dimension LOCI FT4L, Dimension Vista TSH, ADVIA Centaur Cyclosporine, and ADVIA Centaur DHEAS, incorrectly…
Mar 21, 2017Class IIZ-2611-2017Under Investigation by firmThe concentrations for Biotin listed in the Non-Interfering Substances section of the current Dimension and Dimension Vistat Instructions for Use (IFU) for Dimension TNI, Dimension Vista DIGXN, E2, FERR, PRL, and TSH have incorrect units…
Apr 20, 2015Class IIZ-1708-2015Nonconforming Material/ComponentDimension Vista LOCI Thyroid Stimulating Hormone (TSH) Lot 14237AA may produce falsely depressed results ranging from -23% to -96% near the end of the well set due to inadequate reagent volume in a Flex well.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 9.0 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 1 other device also cites its predicate K053531.

How does its category compare?

All CEC devices

CEC Radioimmunoassay, Free Thyroxine: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · CEC

1in 2024

2007: 12008: 22009: 12012: 12013: 22014: 32015: 12016: 12017: 12018: 22023: 12024: 1
2007high 3 (2014) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CEC

238in 2014

2014: 238 days median
2007high 238 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CEC

1in 2018

2010: 32013: 12018: 1
2007high 3 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CEC

213in 2025

2009: 22010: 72011: 152012: 62013: 62014: 402015: 1662016: 1482017: 1962018: 1992019: 1672020: 1062021: 962022: 812023: 992024: 2762025: 213
2007high 276 (2024) · low 0 (2007)2025

MAUDE reports naming product code CEC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—00
20091—02
20100—37
20110—015
20121—06
20132—16
20143238040
20151—0166
20161—0148
20171—0196
20182—1199
20190—0167
20200—0106
20210—096
20220—081
20231—099
20241—0276
20250—0213
20260—0—

What is it indicated for?

The FT4L method is an in vitro diagnostic test for the quantitative measurement of Free Thyroxine in human serum and plasma on the Dimension® EXL™ integrated chemistry system with LOCI® Module. Measurements of free thyroxine are used in the diagnosis and monitoring of thyroid disease.

The TSH method is an in vitro diagnostic test for the quantitative measurement of Thyroid Stimulating Hormone in human serum and plasma on the Dimension Vista® System. Measurements of thyroid stimulating hormone produced by the anterior pituitary are used in the diagnosis of thyroid or pituitary disorders.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140859: Dimension Vista Free Thyroxine Flex Reagent Cartridge, FT4, Dimension Vista Thyroid Stimulating Hormone Flex Reagent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140859

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026