Genasis Hipath Ihc Family

K140957510(k) TraditionalCleared Jan 15, 2015276-day reviewClass II21 CFR 864.1860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Applied Spectral Imaging, Ltd. · NQN Microscope, Automated, Image Analysis, Immunohistochemistry,Operator Intervention,Nuclear Intensity & Percent Positivity

Cleared on Jan 15, 2015 as substantially equivalent to K111543 (Ventana Medical Systems, Inc., 2011) and 3 other predicates after a 276-day review. Its family tree reaches back 3 generations to 2003.

Decided
Jan 15, 2015
Review
276 days
Class
Class II
Product code
NQN
Recalls
None
Predicates
4

Its longest line of descent runs back 3 generations to K032113 (2003). 12 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2013: 1 other ancestor2012: 2 other ancestors2010: 1 other ancestor2008: 1 other ancestor2006: 2 other ancestors2004: 2 other ancestorsK032113 · Acis (Automated Cellular Imaging System) · Chroma Vision Medical Systems, Inc. · 2003K080564 · Scanscope XT System · Aperio Technologies · 2009K111543 · Virtuoso (TM) System for Ihc HER2 (4B5) · Ventana Medical Systems, Inc. · 20112000200520102015
Other ancestors, by generation 1 generation back: 3 other ancestors2 generations back: 2 other ancestors3 generations back: 4 other ancestors K111543 · Virtuoso (TM) System for Ihc HER2 (4B5) · Ventana Medical Systems, Inc. · 2011K080564 · Scanscope XT System · Aperio Technologies · 2009K032113 · Acis (Automated Cellular Imaging System) · Chroma Vision Medical Systems, Inc. · 20030
  1. Root · 3 generations backK032113 Acis (Automated Cellular Imaging System)Chroma Vision Medical Systems, Inc. · 2003
  2. 2 generations backK080564 Scanscope XT SystemAperio Technologies · 2009
  3. 1 generation backK111543 Virtuoso (TM) System for Ihc HER2 (4B5)Ventana Medical Systems, Inc. · 2011
  4. This deviceK140957 Genasis Hipath Ihc FamilyApplied Spectral Imaging, Ltd. · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K032113Acis (Automated Cellular Imaging System)Chroma Vision Medical Systems, Inc.2003—
−2K080564Scanscope XT SystemAperio Technologies2009—
−1K111543Virtuoso (TM) System for Ihc HER2 (4B5)Ventana Medical Systems, Inc.2011—
0 (this device)K140957Genasis Hipath Ihc FamilyApplied Spectral Imaging, Ltd.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200420
200620
200810
201010
201220
201310
FIG. 1 — Lineage of K140957, 2003–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NQN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K111543Virtuoso (TM) System for Ihc HER2 (4B5)
Summary page 9
…tem 1 Owner Applied Spectral Imaging Ltd. Ventana Digital Pathology 2 Legally K……….. K111543 - VirtuosoTM System for IHC HER2 (4B5) distribution Subject to this submission K111869 - VirtuosoTM…
Ventana Medical Systems, Inc.2011—
*K111869Virtuoso System for Ihc PR (IE2)
Summary page 9
…K……….. K111543 - VirtuosoTM System for IHC HER2 (4B5) distribution Subject to this submission K111869 - VirtuosoTM System for IHC PR (1E2) clearance K130515 - VirtuosoTM S…
Ventana Medical Systems, Inc.2012—
*K130515Virtuoso System for Ihc ER (Spi)
Summary page 9
…on Subject to this submission K111869 - VirtuosoTM System for IHC PR (1E2) clearance K130515 - VirtuosoTM System for IHC ER (SP1) No. K111755 - VirtuosoTM S…
Ventana Medical Systems, Inc.2013—
*K111755Virtuoso System for Ihc KI-67 (30-9)
Summary page 9
…K130515 - VirtuosoTM System for IHC ER (SP1) No. K111755 - VirtuosoTM System for IHC Ki67 (30-9) 3 Intended use The GenASIs HiPath IHC Family provides K111543 - VirtuosoT…
Ventana Medical Systems, Inc.2012—

Also cleared against K111543: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 4 companies; a new generation was cleared every 3.3 years on median.
  • 2 of the 12 ancestors have a recall of any class.
  • 1 other device also cites its predicate K111543.

How does its category compare?

All NQN devices

NQN Microscope, Automated, Image Analysis, Immunohistochemistry,Operator Intervention,Nuclear Intensity & Percent Positivity: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · NQN

1in 2015

2007: 12008: 12010: 12012: 22013: 32014: 12015: 1
2007high 3 (2013) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NQN

427in 2013

2013: 427 days median
2007high 427 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NQN

1in 2020

2007: 12008: 12020: 1
2007high 1 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NQN

1in 2023

2016: 12017: 12020: 12023: 1
2007high 1 (2016) · low 0 (2007)2025

MAUDE reports naming product code NQN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—10
20081—10
20090—00
20101—00
20110—00
20122—00
2013342700
20141—00
20151—00
20160—01
20170—01
20180—00
20190—00
20200—11
20210—00
20220—00
20230—01
20240—00
20250—00
20260—0—

What is it indicated for?

The GenASIs HiPath IHC Family provides image capture, management, analysis, and viewing of specific immunohistochemically stained slides. It is intended for in vitro diagnostic use as an aid to the pathologist in the display, detection, counting, review and classification of tissues and cells of clinical interest based on particular morphology, color, intensity, size, pattern and shape: 1. The GenASIs HiPath IHC Family for HER2 (4B5) is for image capture…

Read the full statement (1,060 words)

The GenASIs HiPath IHC Family provides image capture, management, analysis, and viewing of specific immunohistochemically stained slides. It is intended for in vitro diagnostic use as an aid to the pathologist in the display, detection, counting, review and classification of tissues and cells of clinical interest based on particular morphology, color, intensity, size, pattern and shape:

1. The GenASIs HiPath IHC Family for HER2 (4B5) is for image capture and analysis applications. This particular system is intended for use as an aid to the pathologist in the detection and semi-quantitative measurement of HER2 protein in formalin-fixed, paraffin-embedded breast cancer tissue. This device is an accessory to Ventana Medical Systems, Inc. PATHWAY® anti-HER2/neu (4B5) Rabbit Monoclonal Primary Antibody. The PATHWAY® anti-HER2/neu (4B5) Rabbit Monoclonal Primary Antibody is indicated for use as an aid in the assessment of breast cancer patients for whom HERCEPTIN® (Trastuzumab) treatment is being considered.

NOTE: The GenASIs HiPath IHC Family for HER2 (4B5) image capture and analysis applications are adjunctive computer-assisted methodologies for the qualified pathologist in the acquisition and semi-quantitative measurement of images from microscope glass slides of breast cancer specimens stained for the presence of HER-2/neu receptor protein. The pathologist should verify agreement with the Image Analysis software application score by reviewing the glass slide under the microscope. The accuracy of the test results depends on the quality of the immuohistochemical staining. It is the responsibility of a qualified pathologist to employ appropriate morphological studies and controls as specified in the instructions for the PATHWAY® anti-HER-2/neu (4B5) Rabbit Monoclonal Primary Antibody assay used to assure the validity of the GenASIs HiPath IHC Family for HER2 (4B5) image capture and analysis scores. The actual correlation of PATHWAY® anti-HER-2/neu (4B5) to clinical outcome has not been established.

2. The GenASIs HiPath IHC Family for PR (1E2) is for image capture and analysis applications. This particular system is intended for use as an aid to the pathologist in the detection and qualitative measurement of progesterone receptor (PR) protein in formalin-fixed, paraffin-embedded breast cancer tissue. This device is an accessory to Ventana Medical Systems, Inc. CONFIRMTM anti-Progesterone Receptor (PR) (1E2) Rabbit Monoclonal Primary Antibody assay. The CONFIRMTM anti-Progesterone Receptor (PR) (1E2) Rabbit Monoclonal Primary Antibody assay is indicated for use as an aid in the assessment of breast cancer patients for whom endocrine treatment is being considered (but is not the sole basis for treatment).

Note: The GenASIs HiPath IHC for PR (1E2) image capture and analysis applications are adjunctive computer-assisted methodologies for the qualified pathologist in the acquisition and qualitative measurement of images from microscope glass slides of breast cancer specimens stained for the presence of PR protein. The pathologist should verify agreement with the Image Analysis software application score by reviewing the glass slide under the microscope. The accuracy of the test results depends on the quality of the immunohistochemical staining. It is the responsibility of a qualified pathologist to employ appropriate morphological studies and controls as specified in the instructions for the CONFIRMTM anti-Progesterone Receptor (PR) (1E2) Rabbit Monoclonal Primary Antibody used to assure the validity of the GenASIs HiPath IHC Family for PR (1E2) image capture and analysis scores. The actual correlation of CONFIRMTM anti-PR antibody to clinical outcome has not been established.

3. The GenASIs HiPath IHC Family for ER (SP1) is for image capture and analysis applications. The particular system is intended for use as an aid to the pathologist in the detection and qualitative measurement of ER (SP1): protein in formalin-fixed, paraffin-embedded breast cancer tissue. This device is an accessory to the Ventana Medical Systems, Inc. CONFIRMTM anti-Estrogen Receptor (ER) (SP1) Rabbit Monoclonal Primary Antibody. The Ventana Medical Systems, Inc. CONFIRMTM anti-Estrogen Receptor (ER) (SP1) Rabbit Monoclonal Primary Antibody is indicated for use as an aid in the assessment of ER status in breast cancer patients (but is not the sole basis for treatment).

Note: The GenASIs HiPath IHC Family for ER (SP1) image capture and analysis applications are adjunctive computer-assisted methodologies for the qualified pathologist in the acquisition and qualitative measurement of images from microscope glass slides of breast cancer specimens stained for the presence of ER protein. The pathologist should verify agreement with the Image Analysis software application score by reviewing the glass slide under the microscope. The accuracy of the test results depends on the quality of the immuohistochemical staining. It is the responsibility of a qualified pathologist to employ appropriate morphological studies and controls as specified in the instructions for the CONFIRMTM anti-Estrogen Receptor (ER) (SP1) Rabbit Monoclonal Primary Antibody to assure the validity of the GenASIs HiPath IHC Family for ER (SP1) image capture and analysis scores. The actual correlation of CONFIRMTM anti-Estrogen Receptor (ER) (SP1) Rabbit Monoclonal Primary Antibody to clinical outcome has not been established.

4. The GenASIs HiPath IHC Family for Ki67 (30-9) is for image capture and analysis applications. The particular system is intended for use as an aid to the pathologist in the detection and qualitative measurement of Ki67 (30-9): protein in formalin-fixed, paraffin-embedded breast cancer tissue. This device is an accessory to the Ventana Medical Systems, Inc. CONFIRMTM anti-Ki67 (30-9) Rabbit Monoclonal Primary Antibody assay. The Ventana Medical Systems, Inc. CONFIRMTM anti-Ki67 (30-9) assay is indicated for use in assessing the proliferative activity of breast cancer tissue. When used with this assay, the GenASIs HiPath IHC Family for Ki67 (30-9) is indicated for use as an aid in the assessment of Ki-67 status in breast cancer patients (but is not the sole basis for treatment).

Note: The GenASIs HiPath IHC Family for Ki67 (30-9) image capture and analysis applications are adjunctive computer-assisted methodologies for the qualified pathologist in the acquisition and qualitative measurement of images from microscope glass slides of breast cancer specimens stained for the presence of Ki67 protein. The pathologist should verify agreement with the Image Analysis software application score by reviewing the glass slide under the microscope. The accuracy of the test results depends on the quality of the immunohistochemical staining. It is the responsibility of a qualified pathologist to employ appropriate morphological studies and controls as specified in the instructions for the CONFIRMTM anti-Ki67 (30-9) Rabbit Monoclonal Primary Antibody assay to assure the validity of the GenASIs HiPath IHC Family for Ki67 (30-9) image capture and analysis scores. The actual correlation of CONFIRMTM anti-Ki67 (30-9) Rabbit Monoclonal Primary antibody assay to clinical outcome has not been established.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140957: Genasis Hipath Ihc Family.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140957

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026