510(k) Report

510(k) · Cleared

Cleared

FM-3000 Fetal Monitor

K141194510(k) TraditionalCleared Nov 19, 2014195-day reviewClass II21 CFR 884.2740

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Advanced Instrumentations, Inc. · HGM System, Monitoring, Perinatal

Cleared on Nov 19, 2014 as substantially equivalent to K102140 (Edan Instruments, Inc., 2011) after a 195-day review. Its family tree reaches back 6 generations to 1985.

Decided
Nov 19, 2014
Review
195 days
Class
Class II
Product code
HGM
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K852608 (1985). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK852608 Spectra 400 Extended Surveillance & Alert SystemGe Medical Systems Information Technologies · 1985
  2. 5 generations backK991905 Corometrics Model 171 and 172 Fetal MonitorGeneral Electric Medical Systems Information Techn · 1999
  3. 4 generations backK040903 Cadence, Models 2001 and 2002Edan Instruments, Inc. · 2004
  4. 3 generations backK073221 Cadence IIEdan Instruments, Inc. · 2007
  5. 2 generations backK082369 Cadence, Cadence Dual, Cadence II Fetal MonitorEdan Instruments, Inc. · 2008
  6. 1 generation backK102140 Fetal Monitors, Models F2 and F3Edan Instruments, Inc. · 2011 · Recalled
  7. This deviceK141194 FM-3000 Fetal MonitorAdvanced Instrumentations, Inc. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K852608Spectra 400 Extended Surveillance & Alert SystemGe Medical Systems Information Technologies1985—
−5K991905Corometrics Model 171 and 172 Fetal MonitorGeneral Electric Medical Systems Information Techn1999—
−4K040903Cadence, Models 2001 and 2002Edan Instruments, Inc.2004—
−3K073221Cadence IIEdan Instruments, Inc.2007—
−2K082369Cadence, Cadence Dual, Cadence II Fetal MonitorEdan Instruments, Inc.2008—
−1K102140Fetal Monitors, Models F2 and F3Edan Instruments, Inc.20111
0 (this device)K141194FM-3000 Fetal MonitorAdvanced Instrumentations, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
200110
FIG. 1 — Lineage of K141194, 1985–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HGM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HGM device

  1. #1 K241882 Fetal & Maternal Monitor (F15A, F15A Air)score 19.5 · 33 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102140Fetal Monitors, Models F2 and F3
Summary page 6
…K141194 Page 2 of 4 Predicate Device: F3 Fetal Monitor K102140 Manufacturer: EDAN Instruments Device Description: FM-3000 Fetal Monitor With non-invasive ultrasound Doppler, external pressu…
Edan Instruments, Inc.20111

Also cleared against K102140: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 4 companies; a new generation was cleared every 3.8 years on median.
  • 1 of the 8 ancestors has a recall of any class.
  • 1 other device also cites its predicate K102140.

How does its category compare?

All HGM devices

HGM System, Monitoring, Perinatal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · HGM

4in 2025

2007: 32008: 42009: 42010: 42011: 132012: 42013: 22014: 42015: 52016: 12017: 32018: 32020: 12022: 12023: 22024: 12025: 42026 (partial year): 2
2007high 13 (2011) · low 0 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HGM

269in 2025

2007: 56 days median2008: 75 days median2009: 66 days median2010: 193 days median2011: 141 days median2012: 107 days median2014: 231 days median2015: 169 days median2017: 138 days median2018: 258 days median2025: 269 days median
2007high 269 (2025) · low 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HGM

5in 2019

2008: 42009: 62013: 12014: 12019: 52026 (partial year): 2
2007high 6 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HGM

99in 2025

2007: 352008: 172009: 422010: 642011: 832012: 442013: 162014: 302015: 442016: 172017: 272018: 302019: 412020: 192021: 712022: 872023: 692024: 1742025: 99
2007high 174 (2024) · low 16 (2013)2025

MAUDE reports naming product code HGM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007356035
2008475417
2009466642
20104193064
201113141083
20124107044
20132—116
20144231130
20155169044
20161—017
20173138027
20183258030
20190—541
20201—019
20210—071
20221—087
20232—069
20241—0174
20254269099
20262—2—

What is it indicated for?

The FM-3000 Fetal Monitor is intended for non-invasive and invasive monitoring of fetus during antepartum examination, labor and delivery. It is intended to be used only by trained and qualified personnel in antepartum examination rooms, labor and delivery rooms.

It provides Non-stress testing for pregnant women from the 28th week of gestation. It can externally monitor the fetal heart rate using ultrasound and uterine activity via a pressure sensing transducer. Alternatively, it can internally monitor one of the fetal heart rates with an electrocardiograph and uterine activity with an intrauterine pressure catheter.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141194: FM-3000 Fetal Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141194

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026