510(k) Report

510(k) · Cleared

Cleared

ZP9141, ZP9146Y, ZP9146W Non-Rechargeable Battery

K141231510(k) TraditionalCleared Nov 25, 2014196-day reviewClass III21 CFR 870.5310

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zeller Power Products (Battery Beast, LLC) · MKJ Automated External Defibrillators (Non-Wearable)

Cleared on Nov 25, 2014 as substantially equivalent to K031987 (Cardiac Science, 2003) and 1 other predicate after a 196-day review. Its family tree reaches back 7 generations to 1997.

Decided
Nov 25, 2014
Review
196 days
Class
Class III
Product code
MKJ
Recalls
None
Predicates
2

Its longest line of descent runs back 7 generations to K970741 (1997). 13 ancestors in all, the oldest K955628 (1996). No later device cites it as a predicate yet.

  1. Root · 7 generations backK970741 Powerheart AecdCardiac Science, Inc. · 1997 · Recalled
  2. 6 generations backK982710 Aecd Arrhythmia Detection SoftwareCardiac Science, Inc. · 1998 · Recalled
  3. 5 generations backK993533 Powerheart AecdCardiac Science, Inc. · 2000 · Recalled
  4. 4 generations backK011901 Firstsave Star Biphasic, Model 9210/9200Survivalink Corp. · 2002 · Recalled
  5. 3 generations backK022929 Pediatric Attenuated Defibrillation Electrodes, Model 9730…Cardiac Science, Inc. · 2003
  6. 2 generations backK031987 Powerheart Aed G3, Model 9300Cardiac Science · 2003 · Recalled
  7. 1 generation backK040438 Powerheart Aed G3ACardiac Science, Inc. · 2004 · Recalled
  8. This deviceK141231 ZP9141, ZP9146Y, ZP9146W Non-Rechargeable BatteryZeller Power Products (Battery Beast, LLC) · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K970741Powerheart AecdCardiac Science, Inc.19971
−6K982710Aecd Arrhythmia Detection SoftwareCardiac Science, Inc.19981
−5K993533Powerheart AecdCardiac Science, Inc.20001
−4K011901Firstsave Star Biphasic, Model 9210/9200Survivalink Corp.20022
−3K022929Pediatric Attenuated Defibrillation Electrodes, Model 9730, Powederheart Aed…Cardiac Science, Inc.2003—
−2K031987Powerheart Aed G3, Model 9300Cardiac Science200333
−1K040438Powerheart Aed G3ACardiac Science, Inc.200425
0 (this device)K141231ZP9141, ZP9146Y, ZP9146W Non-Rechargeable BatteryZeller Power Products (Battery Beast, LLC)2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
199710
199910
200130
FIG. 1 — Lineage of K141231, 1997–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MKJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031987Powerheart Aed G3, Model 9300
Summary page 4
…70.5310 Automated External Defibrillator III (3) Identification of Predicate Devices - Cardiac Science battery packs 9141-001 and 9146-001 - Approved under K031987 and K040438 for their associated Cardiac Science PowerHeart® or Survivalink AED devices. Legally Marketed Predicate Devices…
Cardiac Science200333
*K040438Powerheart Aed G3A
Summary page 4
…Automated External Defibrillator III (3) Identification of Predicate Devices - Cardiac Science battery packs 9141-001 and 9146-001 - Approved under K031987 and K040438 for their associated Cardiac Science PowerHeart® or Survivalink AED devices. Legally Marketed Predicate Devices The ZP9141…
Cardiac Science, Inc.200425

Also cleared against K031987: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 12 months on median.
  • 9 of the 13 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K031987.

How does its category compare?

All MKJ devices

MKJ Automated External Defibrillators (Non-Wearable): FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · MKJ

48in 2025

2007: 72008: 132009: 82010: 42011: 112012: 102013: 72014: 112015: 62017: 42018: 202019: 252020: 522021: 412022: 192023: 242024: 272025: 482026 (partial year): 31
2007high 52 (2020) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MKJ

156in 2015

2007: 69 days median2008: 141 days median2009: 165 days median2010: 250 days median2011: 36 days median2012: 197 days median2013: 191 days median2014: 196 days median2015: 156 days median
2007high 250 (2010) · low 36 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MKJ

1in 2025

2007: 122008: 242009: 372010: 352011: 72012: 5, 1 Class I2013: 42014: 24, 15 Class I2015: 12016: 2, 1 Class I2017: 6, 4 Class I2018: 32019: 6, 2 Class I2020: 22021: 42022: 32023: 112024: 52025: 12026 (partial year): 3
2007high 37 (2009) · low 1 (2015)2026

Class I (23 since 2007) Class II/III not classified

Adverse event reports per year · MKJ

13,315in 2025

2007: 3,9582008: 4,7522009: 6,7822010: 7,3992011: 8,1702012: 9,7322013: 14,9552014: 15,3992015: 16,1292016: 17,0622017: 16,6842018: 16,5912019: 16,8612020: 16,1972021: 16,3002022: 14,8672023: 13,7662024: 15,1092025: 13,315
2007high 17,062 (2016) · low 3,958 (2007)2025

MAUDE reports naming product code MKJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007769123,958
200813141244,752
20098165376,782
20104250357,399
2011113678,170
2012101975 (1)9,732
20137191414,955
20141119624 (15)15,399
20156156116,129
20160—2 (1)17,062
20174—6 (4)16,684
201820—316,591
201925—6 (2)16,861
202052—216,197
202141—416,300
202219—314,867
202324—1113,766
202427—515,109
202548—113,315
202631—3—

What is it indicated for?

The ZP9141 is a disposable non-rechargeable battery pack for use in the Cardiac Science PowerHeart® Non-G3 Model 9100 and 9200, or Survivalink Non-G3 9100 and 9200 AED’s and is designed to replace the Cardiac Science Model / Part Number 9141-001 battery pack. This battery pack has a shelf life of 5 years from the date of manufacture.

The ZP9146Y (or W) is a disposable non-rechargeable battery pack for use in the Cardiac Science PowerHeart® Non-G3 Model 9300A and 9300E AED’s and is designed to replace the Cardiac Science Model / Part Number 9146-001 battery pack. This battery pack has a shelf life of 5 years from the date of manufacture.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141231: ZP9141, ZP9146Y, ZP9146W Non-Rechargeable Battery.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141231

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026