510(k) Report

510(k) · Cleared

Cleared

Affinity Pixie Oxygenation System with; Carmeda Bioactive Surface, Balance Biosuface

K141233510(k) SpecialCleared Jun 12, 201430-day reviewClass II21 CFR 870.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medtronic, Inc. · DTN Reservoir, Blood, Cardiopulmonary Bypass

Cleared on Jun 12, 2014 as substantially equivalent to K100645 (Medtronic, Inc., 2012) after a 30-day review. Its family tree reaches back 3 generations to 1994. 1 later device descends from it.

Decided
Jun 12, 2014
Review
30 days
Class
Class II
Product code
DTN
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K936003 (1994). 8 ancestors in all, the oldest K831528 (1983). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor1998: 1 other ancestor1994: 1 other ancestor1991: 1 other ancestor1983: 1 other ancestor2017: 1 descendant clearedK936003 · Affinity CVR · Avecor Cardiovascular, Inc. · 1994 · recalledK021287 · Trillium Affinity NT Cardiotomy Venous Reservoir, Models 540T, 541TT · Medtronic Perfusion Systems · 2002 · recalledK100645 · Affinity Pixie Oxygenation System with Carmeda Bioactive Surface or Balance Biosurface · Medtronic, Inc. · 201219801990200020102020
  1. Root · 3 generations backK936003 Affinity CVRAvecor Cardiovascular, Inc. · 1994 · Recalled
  2. 2 generations backK021287 Trillium Affinity NT Cardiotomy Venous Reservoir, Models 540T, 541TTMedtronic Perfusion Systems · 2002 · Recalled
  3. 1 generation backK100645 Affinity Pixie Oxygenation System with Carmeda Bioactive Surface or…Medtronic, Inc. · 2012
  4. This deviceK141233 Affinity Pixie Oxygenation System with; Carmeda Bioactive Surface…Medtronic, Inc. · 2014
  5. Descendant · cites it directly · 0 of its ownK172984 Affinity Pixie Oxygenator with Balance Biosurface, Affinity Pixie…Medtronic, Inc. · 2017

Most influential descendants

Showing 1 of 1 · See all
  • K172984Affinity Pixie Oxygenator with Balance Biosurface, Affinity Pixie Oxygenator with…Medtronic, Inc. · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K936003Affinity CVRAvecor Cardiovascular, Inc.19943
−2K021287Trillium Affinity NT Cardiotomy Venous Reservoir, Models 540T, 541TTMedtronic Perfusion Systems20021
−1K100645Affinity Pixie Oxygenation System with Carmeda Bioactive Surface or Balance…Medtronic, Inc.2012—
0 (this device)K141233Affinity Pixie Oxygenation System with; Carmeda Bioactive Surface, Balance…Medtronic, Inc.2014—
+1K172984Affinity Pixie Oxygenator with Balance Biosurface, Affinity Pixie Oxygenator…Medtronic, Inc.2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198310
199110
199410
199810
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
FIG. 1 — Lineage of K141233, 1994–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DTN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTN device

  1. #1 K251783 Inspire HCR and HCR DUAL cardiotomy reservoirsscore 12.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100645Affinity Pixie Oxygenation System with Carmeda Bioactive Surface or Balance Biosurface
Summary page 1
…I Predicate Devices Medtronic Affinity Pixie& Cardiotomy Venous Reservoir with Carmeda® ioActive Surface or with Balance® Biosurface (K100645) Device Description The Medtronic Affinity Pixie Cardiotomy Venous Reservoir (CVR) is a sin le use devic…
Medtronic, Inc.2012—

Also cleared against K100645: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K172984Affinity Pixie Oxygenator with Balance Biosurface, Affinity Pixie Oxygenator with…Medtronic, Inc.20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 7.9 years on median.
  • 4 of the 8 ancestors have a recall of any class.
  • Of its descendants, K172984 (Medtronic, Inc., 2017) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K100645.

How does its category compare?

All DTN devices

DTN Reservoir, Blood, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · DTN

1in 2025

2007: 22008: 12009: 72010: 12011: 22013: 42014: 32015: 22017: 22023: 12024: 22025: 1
2007high 7 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTN

38in 2014

2009: 211 days median2013: 79 days median2014: 38 days median
2007high 211 (2009) · low 38 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTN

2in 2018

2007: 12008: 12009: 12011: 12016: 12017: 12018: 2
2007high 2 (2018) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DTN

8in 2025

2007: 102008: 82009: 102010: 182011: 102012: 172013: 472014: 522015: 272016: 62017: 32018: 42019: 112020: 62021: 122022: 72023: 82024: 102025: 8
2007high 52 (2014) · low 3 (2017)2025

MAUDE reports naming product code DTN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—110
20081—18
20097211110
20101—018
20112—110
20120—017
2013479047
2014338052
20152—027
20160—16
20172—13
20180—24
20190—011
20200—06
20210—012
20220—07
20231—08
20242—010
20251—08
20260—0—

What is it indicated for?

The Affinity Pixie Hollow Fiber Oxygenator and Cardiotomy/Venous Reservoir with Carmeda Bicactive Surface are indicated for use for neonate, infant, and small pediatric patients undergoing cardiopulmonary bypass procedures requiring a blood flow rate up to 2.0 L/min. The Affinity Pixie Hollow Fiber Oxygenator is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood…

Read the full statement (251 words)

The Affinity Pixie Hollow Fiber Oxygenator and Cardiotomy/Venous Reservoir with Carmeda Bicactive Surface are indicated for use for neonate, infant, and small pediatric patients undergoing cardiopulmonary bypass procedures requiring a blood flow rate up to 2.0 L/min.

The Affinity Pixie Hollow Fiber Oxygenator is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration.

The Affinity Pixie Cardiotomy/Venous Reservoir is intended to be used in an extracorporeal perfusion circuit to collect venous and cardiotomy suctioned blood during routine cardiopulmonary procedures up to 6 hours in duration. The CVR is also intended for use during vacuum assisted venous drainage (VAVD) procedures.

The Affinity Pixie Hollow Fiber Oxygenator and Cardiotomy/Venous Reservoir with Balance Biosurface are indicated for use for neonate, infant, and small pediatric patients undergoing cardiopulmonary bypass procedures requiring a blood flow rate up to 2.0 L/min.

The Affinity Pixie Hallow Fiber Oxygenator is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration.

The Affinity Pixie Cardiotomy/Venous Reservoir is intended to be used in an extracorporeal perfusion circuit to collect venous and cardiotomy suctioned blood during routine cardiopulmonary procedures up to 6 hours in duration. The CVR is also intended for use during vacuum assisted venous drainage (VAVD) procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141233: Affinity Pixie Oxygenation System with; Carmeda Bioactive Surface, Balance Biosuface.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141233

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026