Sterilucent Process Challenge Device

K141312510(k) TraditionalCleared Oct 31, 2014164-day reviewClass II21 CFR 880.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sterilucent, Inc. · FRC Indicator, Biological Sterilization Process

Cleared on Oct 31, 2014 as substantially equivalent to K092906 (STERIS Corporation, 2009) after a 164-day review. Its family tree reaches back 4 generations to 2005. 3 later devices descend from it.

Decided
Oct 31, 2014
Review
164 days
Class
Class II
Product code
FRC
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K042450 (2005). 3 later devices descend from it, 1 citing it directly.

  1. Root · 4 generations backK042450 Sterrad NX Challenge PackAdvanced Sterilization Products · 2005
  2. 3 generations backK051643 Sterrad Sterilizer Cyclesure Test PackAdvanced Sterilization Products · 2005
  3. 2 generations backK073618 Verify Sirius Biological Indicator Challenge PackSTERIS Corporation · 2009
  4. 1 generation backK092906 Verify Biological Indicator Challenge Pack for Vaporized VH202…STERIS Corporation · 2009
  5. This deviceK141312 Sterilucent Process Challenge DeviceSterilucent, Inc. · 2014
  6. Descendant · cites it directly · 2 of its ownK192001 Sterilucent self-Contained Biological Indicator, Sterilucent Lumen…Sterilucent, Inc. · 2019
  7. Descendant · 2 generations on · 1 of its ownK233814 3M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge…3M Company · 2024
  8. Descendant · 3 generations on · 0 of its ownK241542 3M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge…3M Company · 2024

Most influential descendants

Showing 3 of 3 · See all
  • K192001Sterilucent self-Contained Biological Indicator, Sterilucent Lumen Cycle Process…Sterilucent, Inc. · 2019 · cites it directly2descendants
  • K2338143M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack (1295PCD); 3M™…3M Company · 2024 · 2 generations on1descendant
  • K2415423M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack 1295PCD (1295PCD)3M Company · 2024 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K042450Sterrad NX Challenge PackAdvanced Sterilization Products2005—
−3K051643Sterrad Sterilizer Cyclesure Test PackAdvanced Sterilization Products2005—
−2K073618Verify Sirius Biological Indicator Challenge PackSTERIS Corporation2009—
−1K092906Verify Biological Indicator Challenge Pack for Vaporized VH202 SterilizationSTERIS Corporation2009—
0 (this device)K141312Sterilucent Process Challenge DeviceSterilucent, Inc.2014—
+1K192001Sterilucent self-Contained Biological Indicator, Sterilucent Lumen Cycle…Sterilucent, Inc.2019—
+2K2338143M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack…3M Company2024—
+3K2415423M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack…3M Company2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202420
FIG. 1 — Lineage of K141312, 2005–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRC device

  1. #1 K250044 Celerity 5 HP Biological Indicator (LCB052)…score 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K092906Verify Biological Indicator Challenge Pack for Vaporized VH202 Sterilization
Summary page 5
…evice Class: Class I Product Code: FRC (21 CFR 880.2800) Predicate Device Steris Verify Biological Indicator Challenge Pack for Vaporized H202 Sterilization Processes (K092906) Device Description The Sterilucent PCD-L and PCD-NL are pre-assembled devices that consist of a Sterilucent Self-Contained Bio…
STERIS Corporation2009—

Also cleared against K092906: 1 other device →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K192001Sterilucent self-Contained Biological Indicator, Sterilucent Lumen Cycle Process…Sterilucent, Inc.20192

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 3.4 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K192001 (Sterilucent, Inc., 2019) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K092906.

How does its category compare?

All FRC devices

FRC Indicator, Biological Sterilization Process: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · FRC

6in 2025

2007: 32008: 12009: 62010: 42011: 62012: 92013: 42014: 132015: 32016: 22017: 102018: 182019: 52020: 102021: 52022: 52023: 62024: 82025: 62026 (partial year): 1
2007high 18 (2018) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRC

29in 2025

2007: 83 days median2009: 183 days median2010: 165 days median2011: 118 days median2012: 178 days median2013: 260 days median2014: 174 days median2015: 130 days median2017: 130 days median2018: 97 days median2019: 88 days median2020: 150 days median2021: 107 days median2022: 193 days median2023: 190 days median2024: 105 days median2025: 29 days median
2007high 260 (2013) · low 29 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRC

8so far in 2026, the most since 2007

2009: 12012: 22013: 22022: 42023: 12026 (partial year): 8
2007high 8 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRC

9in 2025

2007: 1002008: 602009: 452010: 572011: 372012: 462013: 392014: 512015: 1822016: 4822017: 1822018: 222019: 302020: 162021: 102022: 92023: 202024: 222025: 9
2007high 482 (2016) · low 9 (2022)2025

MAUDE reports naming product code FRC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073830100
20081—060
20096183145
20104165057
20116118037
20129178246
20134260239
201413174051
201531300182
20162—0482
2017101300182
20181897022
2019588030
202010150016
20215107010
2022519349
20236190120
20248105022
202562909
20261—8—

What is it indicated for?

The Sterilucent Process Challenge Device PCD-L for Lumen Cycle is used for performance qualification of the Sterilucent PSD-85 sterilizer during initial installation, after relocation, major repairs or malfunctions, or after sterilization process failures. The Sterilucent PCD-L may also be used for routine monitoring of the PSD-85 Sterilizer Lumen Cycle. The Sterilucent Process Challenge Device PCD-NL for Non-Lumen Cycle is used for performance…

Read the full statement (98 words)

The Sterilucent Process Challenge Device PCD-L for Lumen Cycle is used for performance qualification of the Sterilucent PSD-85 sterilizer during initial installation, after relocation, major repairs or malfunctions, or after sterilization process failures. The Sterilucent PCD-L may also be used for routine monitoring of the PSD-85 Sterilizer Lumen Cycle.

The Sterilucent Process Challenge Device PCD-NL for Non-Lumen Cycle is used for performance qualification of the Sterilucent PSD-85 Sterilizer during initial installation, after relocation, major repairs or malfunctions, or after sterilization process failures. The Sterilucent PCD-NL may also be used for routine monitoring of the PSD-85 Sterilizer Non-Lumen Cycle.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K141312: Sterilucent Process Challenge Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141312

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026