510(k) Report

510(k) · Cleared

Cleared

Celerity™ 20 HP Biological Indicator

K252680510(k) SpecialCleared Sep 24, 202530-day reviewClass II21 CFR 880.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

STERIS Corporation · FRC Indicator, Biological Sterilization Process

Cleared on Sep 24, 2025 as substantially equivalent to K231490 (STERIS Corporation, 2023) after a 30-day review. Its family tree reaches back 10 generations to 2005.

Decided
Sep 24, 2025
Review
30 days
Class
Class II
Product code
FRC
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K042450 (2005). 17 ancestors in all, the oldest K994055 (2002). No later device cites it as a predicate yet.

  1. Root · 10 generations backK042450 Sterrad NX Challenge PackAdvanced Sterilization Products · 2005
  2. 6 generations between
  3. 3 generations backK172752 CELERITY 20 HP Biological IndicatorSTERIS Corporation · 2018
  4. 2 generations backK183294 CELERITY 20 HP Biological Indicator, CELERITY HP Challenge PackSTERIS Corporation · 2019
  5. 1 generation backK231490 Celerity 20 HP Biological Indicator; VERIFY V24 Self-Contained…STERIS Corporation · 2023
  6. This deviceK252680 Celerity™ 20 HP Biological IndicatorSTERIS Corporation · 2025
Show all 10 generations
  1. Root · 10 generations backK042450 Sterrad NX Challenge PackAdvanced Sterilization Products · 2005
  2. 9 generations backK051643 Sterrad Sterilizer Cyclesure Test PackAdvanced Sterilization Products · 2005
  3. 8 generations backK073618 Verify Sirius Biological Indicator Challenge PackSTERIS Corporation · 2009
  4. 7 generations backK092906 Verify Biological Indicator Challenge Pack for Vaporized VH202…STERIS Corporation · 2009
  5. 6 generations backK103331 Verify Biological Indicator Challenge Pack for Vaporized VH202…STERIS Corporation · 2011
  6. 5 generations backK140499 Verify V24 Self-Contained Biological Indicator for Vaporized VH202…STERIS Corporation · 2014
  7. 4 generations backK171504 VERIFY Assert VH2O2 Self-Contained Biological IndicatorSTERIS Corporation · 2017 · Recalled
  8. 3 generations backK172752 CELERITY 20 HP Biological IndicatorSTERIS Corporation · 2018
  9. 2 generations backK183294 CELERITY 20 HP Biological Indicator, CELERITY HP Challenge PackSTERIS Corporation · 2019
  10. 1 generation backK231490 Celerity 20 HP Biological Indicator; VERIFY V24 Self-Contained…STERIS Corporation · 2023
  11. This deviceK252680 Celerity™ 20 HP Biological IndicatorSTERIS Corporation · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K042450Sterrad NX Challenge PackAdvanced Sterilization Products2005—
−9K051643Sterrad Sterilizer Cyclesure Test PackAdvanced Sterilization Products2005—
−8K073618Verify Sirius Biological Indicator Challenge PackSTERIS Corporation2009—
−7K092906Verify Biological Indicator Challenge Pack for Vaporized VH202 SterilizationSTERIS Corporation2009—
−6K103331Verify Biological Indicator Challenge Pack for Vaporized VH202 Sterilization…STERIS Corporation2011—
−5K140499Verify V24 Self-Contained Biological Indicator for Vaporized VH202…STERIS Corporation2014—
−4K171504VERIFY Assert VH2O2 Self-Contained Biological IndicatorSTERIS Corporation20171
−3K172752CELERITY 20 HP Biological IndicatorSTERIS Corporation2018—
−2K183294CELERITY 20 HP Biological Indicator, CELERITY HP Challenge PackSTERIS Corporation2019—
−1K231490Celerity 20 HP Biological Indicator; VERIFY V24 Self-Contained Biological…STERIS Corporation2023—
0 (this device)K252680Celerity™ 20 HP Biological IndicatorSTERIS Corporation2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200710
200810
201820
201910
FIG. 1 — Lineage of K252680, 2005–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRC device

  1. #1 K250044 Celerity 5 HP Biological Indicator (LCB052)…score 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K231490Celerity 20 HP Biological Indicator; VERIFY V24 Self-Contained Biological Indicator
Summary page 6
…dicator Classification Name: Indicator, Biological Sterilization Process 510(k) Submitter/Holder STERIS Corporation 510(k) Number: K231490 3. Description of Device The product is intended to monitor the vapor phased hydrogen peroxide sterilization cycles desc…
STERIS Corporation2023—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 2 companies; a new generation was cleared every 2.1 years on median.
  • 3 of the 17 ancestors have a recall of any class.

How does its category compare?

All FRC devices

FRC Indicator, Biological Sterilization Process: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · FRC

6in 2025

2007: 32008: 12009: 62010: 42011: 62012: 92013: 42014: 132015: 32016: 22017: 102018: 182019: 52020: 102021: 52022: 52023: 62024: 82025: 62026 (partial year): 1
2007high 18 (2018) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRC

29in 2025

2007: 83 days median2009: 183 days median2010: 165 days median2011: 118 days median2012: 178 days median2013: 260 days median2014: 174 days median2015: 130 days median2017: 130 days median2018: 97 days median2019: 88 days median2020: 150 days median2021: 107 days median2022: 193 days median2023: 190 days median2024: 105 days median2025: 29 days median
2007high 260 (2013) · low 29 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRC

8so far in 2026, the most since 2007

2009: 12012: 22013: 22022: 42023: 12026 (partial year): 8
2007high 8 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRC

9in 2025

2007: 1002008: 602009: 452010: 572011: 372012: 462013: 392014: 512015: 1822016: 4822017: 1822018: 222019: 302020: 162021: 102022: 92023: 202024: 222025: 9
2007high 482 (2016) · low 9 (2022)2025

MAUDE reports naming product code FRC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073830100
20081—060
20096183145
20104165057
20116118037
20129178246
20134260239
201413174051
201531300182
20162—0482
2017101300182
20181897022
2019588030
202010150016
20215107010
2022519349
20236190120
20248105022
202562909
20261—8—

What is it indicated for?

The Celerity™ 20 HP Biological Indicator (Bl) is intended for routine monitoring of the following sterilizer cycles:

• Lumen, Non Lumen, Fast Non Lumen, Fast, Flexible and Specialty Cycles of the V-PRO 1, 1 Plus, maX, maX 2, 60 and s2 Low Temperature Sterilization Systems.

• STERRAD® 100S Sterilizer (Default Cycle)

• Standard and Advanced Cycles of the STERRAD® NX® Sterilizer with or without ALLClear

• Standard, FLEX, Express and DUO Cycles of the STERRAD® 100NX® Sterilizer with or without ALLClear® Technology

When used in conjunction with the Celerity™ HP Incubator or the Celerity™ Incubator, the Celerity™ 20 HP Bl provides a fluorescent result within 20 minutes.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K252680: Celerity™ 20 HP Biological Indicator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K252680

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026