510(k) Report

510(k) · Cleared

Cleared

Instafix Shape Memory Fixation System

K141550510(k) SpecialCleared Jul 11, 201430-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ot Medical · JDR Staple, Fixation, Bone

Cleared on Jul 11, 2014 as substantially equivalent to K071477 (Core Essence Orthopaedics, LLC, 2007) after a 30-day review. Its family tree reaches back 4 generations to 1990.

Decided
Jul 11, 2014
Review
30 days
Class
Class II
Product code
JDR
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K902307 (1990). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK902307 Shaw II Hemostatic Surgery SystemHemostatic Surgery Corp. · 1990 · Recalled
  2. 3 generations backK993714 Memograph Staple, Warm SystemBiomedical Ent., Inc. · 2000
  3. 2 generations backK051408 Intelifuse, Inc. Warm System with StimulinksIntelifuse, Inc. · 2005
  4. 1 generation backK071477 Reverto 55 and 37 Shape Memory StaplesCore Essence Orthopaedics, LLC · 2007
  5. This deviceK141550 Instafix Shape Memory Fixation SystemOt Medical · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K902307Shaw II Hemostatic Surgery SystemHemostatic Surgery Corp.19902
−3K993714Memograph Staple, Warm SystemBiomedical Ent., Inc.2000—
−2K051408Intelifuse, Inc. Warm System with StimulinksIntelifuse, Inc.2005—
−1K071477Reverto 55 and 37 Shape Memory StaplesCore Essence Orthopaedics, LLC2007—
0 (this device)K141550Instafix Shape Memory Fixation SystemOt Medical2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200120
200610
FIG. 1 — Lineage of K141550, 1990–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JDR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JDR device

  1. #1 K243658 TMC Compression Implant Systemscore 16.7 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071477Reverto 55 and 37 Shape Memory Staples
Summary page 1
…allic bone fixation Name appliances and accessories Section Orthopedic Product Code JDR Predicate Device reVERTOTM Shape Memory Staples (K07 1477) Device InstaFixTM Shape Memory Fixation System is a set of dynamic Description compression implants made from…
Core Essence Orthopaedics, LLC2007—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 5 companies; a new generation was cleared every 6.9 years on median.
  • 1 of the 8 ancestors has a recall of any class.

How does its category compare?

All JDR devices

JDR Staple, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · JDR

3in 2025

2007: 82008: 52010: 22011: 12012: 12013: 92014: 112015: 72016: 62017: 92018: 82019: 52020: 42021: 32022: 52023: 92024: 42025: 32026 (partial year): 2
2007high 11 (2014) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JDR

65in 2025

2007: 70 days median2008: 89 days median2013: 137 days median2014: 97 days median2015: 111 days median2016: 101 days median2017: 172 days median2018: 107 days median2019: 149 days median2020: 161 days median2021: 62 days median2022: 107 days median2023: 72 days median2024: 29 days median2025: 65 days median
2007high 172 (2017) · low 29 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JDR

11in 2022

2008: 12015: 12018: 12020: 12022: 112026 (partial year): 2
2007high 11 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JDR

314in 2025

2007: 32008: 142009: 102010: 352011: 622012: 342013: 272014: 492015: 482016: 762017: 1162018: 2392019: 2422020: 2342021: 2102022: 2022023: 1752024: 2062025: 314
2007high 314 (2025) · low 3 (2007)2025

MAUDE reports naming product code JDR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200787003
2008589114
20090—010
20102—035
20111—062
20121—034
20139137027
20141197049
20157111148
20166101076
201791720116
201881071239
201951490242
202041611234
20213620210
2022510711202
20239720175
20244290206
20253650314
20262—2—

What is it indicated for?

InstaFiXTM Shape Memory Fixation System is intended for use in:

Fixation of Osteotomies of the Hand, Foot and Tibia

Arthrodesis of the Joints of the Hand and Foot

Fixation of Soft Tissue to Bone, as in the case of the Anterior Cruciate Ligament

InstaFiXTM Shape Memory Fixation System is also indicated for adjunctive fixation of

Small Bone Fragments of:

The Upper Extremity, such as the Radius, Ulna, Humerus. Clavicle and Scapula

The Lower Extremity, such as the Tibia, Fibula and the Femur

The Upper Torso, such as the Sternum and the Ribs

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141550: Instafix Shape Memory Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141550

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026