510(k) Report

510(k) · Cleared

Cleared

Disposable Injection Needle

K142144510(k) TraditionalCleared Jan 15, 2015163-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wilson Instruments (Shanghai) Company Limited · FBK Endoscopic Injection Needle, Gastroenterology-Urology

Cleared on Jan 15, 2015 as substantially equivalent to K011484 (Olympus Optical Co., Ltd., 2001) after a 163-day review. Its family tree reaches back 1 generation to 2001.

Decided
Jan 15, 2015
Review
163 days
Class
Class II
Product code
FBK
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K011484 (2001). No later device cites it as a predicate yet.

  1. Root · 1 generation backK011484 Olympus Injector NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-9-1Olympus Optical Co., Ltd. · 2001
  2. This deviceK142144 Disposable Injection NeedleWilson Instruments (Shanghai) Company Limited · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K011484Olympus Injector NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-9-1Olympus Optical Co., Ltd.2001—
0 (this device)K142144Disposable Injection NeedleWilson Instruments (Shanghai) Company Limited2015—
FIG. 1 — Lineage of K142144, 2001–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FBK device

  1. #1 K253598 InjecSURE Injection Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K011484Olympus Injector NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-9-1
Summary page 6
…ion are as follows: Olympus Optical Co., Ltd., Olympus Injector NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-7-1, NM-8-1, NM-9-1 has been cleared by FDA through 510(k) No. K011484 (Decision Date – Aug 10, 2001). 5. Description of the Device [21 CFR 807.92(a)(4)] The subjected Disposable Injection Needle is…
Olympus Optical Co., Ltd.2001—

Also cleared against K011484: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K011484.

How does its category compare?

All FBK devices

FBK Endoscopic Injection Needle, Gastroenterology-Urology: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · FBK

3in 2025

2008: 12009: 42011: 12012: 22014: 22015: 32016: 22017: 32018: 22019: 12020: 22021: 12022: 62023: 32024: 42025: 32026 (partial year): 2
2007high 6 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FBK

155in 2025

2009: 101 days median2015: 103 days median2017: 51 days median2022: 213 days median2023: 177 days median2024: 192 days median2025: 155 days median
2007high 213 (2022) · low 51 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FBK

9in 2024

2016: 12021: 202022: 82023: 12024: 92026 (partial year): 1
2007high 20 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FBK

81in 2025

2007: 32008: 222009: 122010: 122011: 22012: 22013: 32014: 92015: 42016: 182017: 272018: 92019: 62020: 252021: 342022: 802023: 602024: 942025: 81
2007high 94 (2024) · low 2 (2011)2025

MAUDE reports naming product code FBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20081—022
20094101012
20100—012
20111—02
20122—02
20130—03
20142—09
2015310304
20162—118
2017351027
20182—09
20191—06
20202—025
20211—2034
20226213880
20233177160
20244192994
20253155081
20262—1—

What is it indicated for?

Wilson disposable injection needle has been designed to be used with an endoscope to perform following therapy:

1. Endoscopic sclerotherapy within the esophagus, stomach, duodenum, small intestine, large intestine.

2. Endoscopic hemostasis within the esophagus, stomach, duodenum, small intestine, large intestine.

3. Endoscopic submucosal injection within esophagus, stomach, duodenum, small intestine, large intestine.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K142144: Disposable Injection Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K142144

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026