510(k) Report

510(k) · Cleared

Recalled · Class II · 2021

Single Use Injector NM600/610

K153625510(k) TraditionalCleared Feb 12, 201656-day reviewClass II21 CFR 876.1500Recalls 20

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Olympus Medical Systems Corp. · FBK Endoscopic Injection Needle, Gastroenterology-Urology

Cleared on Feb 12, 2016 as substantially equivalent to K011484 (Olympus Optical Co., Ltd., 2001) and 2 other predicates after a 56-day review. Its family tree reaches back 3 generations to 1996. 4 later devices descend from it. It has been recalled 20 times.

Decided
Feb 12, 2016
Review
56 days
Class
Class II
Product code
FBK
Recalls
20
Predicates
3

Its longest line of descent runs back 3 generations to K955558 (1996). 5 ancestors in all, the oldest K902736 (1990). 4 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1990: 1 other ancestor2025: 2 descendants cleared2022: 1 descendant cleared2024: 1 descendant clearedK955558 · Gip/Medi-Globe Sclerotherapy Needles · Medi-Globe Corp. · 1996K061222 · Injectra Injection Needle · Medi-Globe Corp. · 2006K132065 · Injection Needle · Endochoice, Inc. · 20141990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 2 descendants K132065 · Injection Needle · Endochoice, Inc. · 2014K061222 · Injectra Injection Needle · Medi-Globe Corp. · 2006K955558 · Gip/Medi-Globe Sclerotherapy Needles · Medi-Globe Corp. · 19960
  1. Root · 3 generations backK955558 Gip/Medi-Globe Sclerotherapy NeedlesMedi-Globe Corp. · 1996
  2. 2 generations backK061222 Injectra Injection NeedleMedi-Globe Corp. · 2006
  3. 1 generation backK132065 Injection NeedleEndochoice, Inc. · 2014
  4. This deviceK153625 Single Use Injector NM600/610Olympus Medical Systems Corp. · 2016
  5. Descendant · cites it directly · 2 of its ownK213914 Injection NeedleJiangsu Vedkang Medical Science and Technology Co., Ltd. · 2022
  6. Descendant · 2 generations on · 0 of its ownK252021 Disposable Endoscopic Injection NeedlesChangzhou New Med Micro-Medtech Co., Ltd. · 2025
  7. Descendant · cites it directly · 0 of its ownK252247 Injector Force Max Single Use Injector (NM-400L); Injector Force Max…Olympus Medical Systems Corporation · 2025
  8. Descendant · 2 generations on · 0 of its ownK232200 Disposable Injection NeedlesNingbo Xinwell Medical Technology Co., Ltd. · 2024

Most influential descendants

Showing 4 of 4 · See all
  • K213914Injection NeedleJiangsu Vedkang Medical Science and Technology Co., Ltd. · 2022 · cites it directly2descendants
  • K252021Disposable Endoscopic Injection NeedlesChangzhou New Med Micro-Medtech Co., Ltd. · 2025 · 2 generations on0descendants
  • K252247Injector Force Max Single Use Injector (NM-400L); Injector Force Max Single Use Injector…Olympus Medical Systems Corporation · 2025 · cites it directly0descendants
  • K232200Disposable Injection NeedlesNingbo Xinwell Medical Technology Co., Ltd. · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K955558Gip/Medi-Globe Sclerotherapy NeedlesMedi-Globe Corp.1996—
−2K061222Injectra Injection NeedleMedi-Globe Corp.2006—
−1K132065Injection NeedleEndochoice, Inc.2014—
0 (this device)K153625Single Use Injector NM600/610Olympus Medical Systems Corp.2016—
+1K213914Injection NeedleJiangsu Vedkang Medical Science and Technology Co., Ltd.2022—
+2K252021Disposable Endoscopic Injection NeedlesChangzhou New Med Micro-Medtech Co., Ltd.2025—
+1K252247Injector Force Max Single Use Injector (NM-400L); Injector Force Max Single…Olympus Medical Systems Corporation2025—
+2K232200Disposable Injection NeedlesNingbo Xinwell Medical Technology Co., Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202410
202520
FIG. 1 — Lineage of K153625, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FBK device

  1. #1 K253598 InjecSURE Injection Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K011484Olympus Injector NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-9-1
Summary page 6
…Device Trade Common Name Applicant 510(k) No. Name Olympus Injector OLYMPUS OPTICAL Co., K011484 Injector Ltd. NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-9-1, NM-4U-1, NM-4Z-1 NM Injection Steri…
Olympus Optical Co., Ltd.2001—
*K902736NM Injection Needles
Summary page 6
…Ltd. NM-4-1, NM-5-1, NM-6-1, NM-7-1, NM-8-1, NM-9-1, NM-4U-1, NM-4Z-1 NM Injection Sterile OLYMPUS Corporation. K902736 Needles Injection Needle Injection Injection ENDOCHOICE, INC. K…
Olympus Corp.1990—
*K132065Injection Needle
Summary page 6
…US Corporation. K902736 Needles Injection Needle Injection Injection ENDOCHOICE, INC. K132065 Needle Needle 5.4 Device Description This instrument has been designed to be used with an Olympus endoscope to p…
Endochoice, Inc.2014—

Also cleared against K011484: 1 other device →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K213914Injection NeedleJiangsu Vedkang Medical Science and Technology Co., Ltd.20222
K252247Injector Force Max Single Use Injector (NM-400L); Injector Force Max Single Use Injector…Olympus Medical Systems Corporation20250

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 4, 2021Class IIZ-1032-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1038-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1041-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1043-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1047-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1030-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1046-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1049-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1033-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1037-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1040-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1042-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1048-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1031-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1034-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1035-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1036-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1039-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1044-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.
Jan 4, 2021Class IIZ-1045-2021Under Investigation by firmInspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 7.5 years on median.
  • None of the 5 ancestors has a recall.
  • Of its descendants, K213914 (Jiangsu Vedkang Medical Science and Technology Co., Ltd., 2022) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K011484.

How does its category compare?

All FBK devices

FBK Endoscopic Injection Needle, Gastroenterology-Urology: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · FBK

3in 2025

2008: 12009: 42011: 12012: 22014: 22015: 32016: 22017: 32018: 22019: 12020: 22021: 12022: 62023: 32024: 42025: 32026 (partial year): 2
2007high 6 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FBK

155in 2025

2009: 101 days median2015: 103 days median2017: 51 days median2022: 213 days median2023: 177 days median2024: 192 days median2025: 155 days median
2007high 213 (2022) · low 51 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FBK

9in 2024

2016: 12021: 202022: 82023: 12024: 92026 (partial year): 1
2007high 20 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FBK

81in 2025

2007: 32008: 222009: 122010: 122011: 22012: 22013: 32014: 92015: 42016: 182017: 272018: 92019: 62020: 252021: 342022: 802023: 602024: 942025: 81
2007high 94 (2024) · low 2 (2011)2025

MAUDE reports naming product code FBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20081—022
20094101012
20100—012
20111—02
20122—02
20130—03
20142—09
2015310304
20162—118
2017351027
20182—09
20191—06
20202—025
20211—2034
20226213880
20233177160
20244192994
20253155081
20262—1—

What is it indicated for?

This instrument has been designed to be used with an Olympus endoscope to perform endoscopic vascular or submucosal injection in the GI tract.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K153625: Single Use Injector NM600/610.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K153625

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026