510(k) · Cleared
ClearedInsightra Freedom Ventral Hernia Repair System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Insightra Medical · FTL Mesh, Surgical, Polymeric
Cleared on May 7, 2015 as substantially equivalent to K002093 (Atrium Medical Corp., 2000) and 1 other predicate after a 269-day review. Its family tree reaches back 1 generation to 1990.
- Decided
- May 7, 2015
- Review
- 269 days
- Class
- Class II
- Product code
- FTL
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K905655 (1990). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK905655 Nonabsorbable Polypropylene Surgical MeshUnited States Surgical, A Division of Tyco Healthc · 1990
- This deviceK142192 Insightra Freedom Ventral Hernia Repair SystemInsightra Medical · 2015
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K905655 | Nonabsorbable Polypropylene Surgical Mesh | United States Surgical, A Division of Tyco Healthc | 1990 | — |
| 0 (this device) | K142192 | Insightra Freedom Ventral Hernia Repair System | Insightra Medical | 2015 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FTL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FTL device
- #1 K220091 Poly-Tape/Infinity-Lock Soft Tissue…score 16.8 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K002093 | Atrium Lite MeshSummary page 4…: Surgical Polymeric Mesh Classification Code: Class II, § 878.3300, Product Code FTL Predicate Devices: • Atrium Prolite Mesh, K002093, FDA cleared on 7/24/2000 • Covidien Surgipro Mesh, K905655, FDA cleared on 12/31/1990… | 2000 |
| * | K905655 | Nonabsorbable Polypropylene Surgical MeshSummary page 4…Class II, § 878.3300, Product Code FTL Predicate Devices: • Atrium Prolite Mesh, K002093, FDA cleared on 7/24/2000 • Covidien Surgipro Mesh, K905655, FDA cleared on 12/31/1990 K142192, Page 2 of… | 1990 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 2 ancestors has a recall.
- 3 other devices also cite its predicate K002093.
How does its category compare?
All FTL devicesFTL Mesh, Surgical, Polymeric: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.
FDA decisions per year · FTL
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FTL
30in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FTL
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FTL
3,487in 2025
MAUDE reports naming product code FTL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 92 | 2 | 1,737 |
| 2008 | 23 | 114 | 1 | 1,569 |
| 2009 | 15 | 97 | 1 | 1,906 |
| 2010 | 18 | 132 | 12 | 2,175 |
| 2011 | 15 | 90 | 8 | 3,608 |
| 2012 | 12 | 213 | 2 | 14,700 |
| 2013 | 8 | 90 | 1 | 26,519 |
| 2014 | 11 | 70 | 3 | 2,683 |
| 2015 | 12 | 121 | 0 | 2,526 |
| 2016 | 3 | 186 | 0 | 2,417 |
| 2017 | 6 | 132 | 1 | 3,947 |
| 2018 | 12 | 105 | 1 | 11,893 |
| 2019 | 4 | 99 | 0 | 21,724 |
| 2020 | 5 | 138 | 1 | 18,819 |
| 2021 | 2 | — | 0 | 16,284 |
| 2022 | 6 | 195 | 0 | 11,439 |
| 2023 | 4 | 29 | 0 | 8,025 |
| 2024 | 2 | — | 0 | 8,565 |
| 2025 | 6 | 30 | 0 | 3,487 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The Insightra Freedom Ventral Hernia Repair System is intended for use in the open repair of ventral hernias.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K142192 · printed Nov 3, 2026
Cite this page
510(k) Report. “K142192: Insightra Freedom Ventral Hernia Repair System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K142192
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026