510(k) · Cleared
ClearedNonabsorbable Polypropylene Surgical Mesh
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
United States Surgical, A Division of Tyco Healthc · FTL Mesh, Surgical, Polymeric
Cleared on Dec 31, 1990 after a 13-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 30 later devices descend from it.
- Decided
- Dec 31, 1990
- Review
- 13 days
- Class
- Class II
- Product code
- FTL
- Recalls
- None
- Predicates
- 0
30 later devices descend from it, 4 citing it directly.
- This deviceK905655 Nonabsorbable Polypropylene Surgical MeshUnited States Surgical, A Division of Tyco Healthc · 1990
- Descendant · cites it directly · 27 of its ownK041632 Minimesh Polypropylene MeshMpathy Medical Devices, Ltd. · 2004 · Recalled
- Descendant · 2 generations on · 16 of its ownK053361 Modification to: Minimesh Polypropylene MeshMpathy Medical Devices, Ltd. · 2006 · Recalled
- Descendant · 2 generations on · 13 of its ownK092207 Restorelle Polypropylene MeshMpathy Medical Devices, Inc. · 2009
- Descendant · 3 generations on · 9 of its ownK090739 Bard Sacrocolpopexy GraftC.R. Bard, Inc. · 2009
- Descendant · 4 generations on · 8 of its ownK101722 Alyte Y-Mesh GraftC.R. Bard, Inc. · 2011
Showing 5 of 30 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 30 · See all- K041632Minimesh Polypropylene MeshMpathy Medical Devices, Ltd. · 2004 · cites it directly27descendants
- K053361Modification to: Minimesh Polypropylene MeshMpathy Medical Devices, Ltd. · 2006 · 2 generations on16descendants
- K092207Restorelle Polypropylene MeshMpathy Medical Devices, Inc. · 2009 · 2 generations on13descendants
- K090739Bard Sacrocolpopexy GraftC.R. Bard, Inc. · 2009 · 3 generations on9descendants
- K101722Alyte Y-Mesh GraftC.R. Bard, Inc. · 2011 · 4 generations on8descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K905655 | Nonabsorbable Polypropylene Surgical Mesh | United States Surgical, A Division of Tyco Healthc | 1990 | — |
| +1 | K041632 | Minimesh Polypropylene Mesh | Mpathy Medical Devices, Ltd. | 2004 | 1 |
| +2 | K053361 | Modification to: Minimesh Polypropylene Mesh | Mpathy Medical Devices, Ltd. | 2006 | 1 |
| +2 | K092207 | Restorelle Polypropylene Mesh | Mpathy Medical Devices, Inc. | 2009 | — |
| +3 | K090739 | Bard Sacrocolpopexy Graft | C.R. Bard, Inc. | 2009 | — |
| +4 | K101722 | Alyte Y-Mesh Graft | C.R. Bard, Inc. | 2011 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
| 2004 | 1 | 0 |
| 2006 | 2 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2010 | 3 | 0 |
| 2011 | 2 | 0 |
| 2012 | 5 | 0 |
| 2013 | 2 | 0 |
| 2014 | 2 | 0 |
| 2015 | 3 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FTL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FTL device
- #1 K220091 Poly-Tape/Infinity-Lock Soft Tissue…score 16.8 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (30)
See all 304 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K041632 (Mpathy Medical Devices, Ltd., 2004) has gone furthest, with 27 descendants of its own.
How does its category compare?
All FTL devicesFTL Mesh, Surgical, Polymeric: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FTL
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FTL
30in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FTL
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FTL
3,487in 2025
MAUDE reports naming product code FTL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 92 | 2 | 1,737 |
| 2008 | 23 | 114 | 1 | 1,569 |
| 2009 | 15 | 97 | 1 | 1,906 |
| 2010 | 18 | 132 | 12 | 2,175 |
| 2011 | 15 | 90 | 8 | 3,608 |
| 2012 | 12 | 213 | 2 | 14,700 |
| 2013 | 8 | 90 | 1 | 26,519 |
| 2014 | 11 | 70 | 3 | 2,683 |
| 2015 | 12 | 121 | 0 | 2,526 |
| 2016 | 3 | 186 | 0 | 2,417 |
| 2017 | 6 | 132 | 1 | 3,947 |
| 2018 | 12 | 105 | 1 | 11,893 |
| 2019 | 4 | 99 | 0 | 21,724 |
| 2020 | 5 | 138 | 1 | 18,819 |
| 2021 | 2 | — | 0 | 16,284 |
| 2022 | 6 | 195 | 0 | 11,439 |
| 2023 | 4 | 29 | 0 | 8,025 |
| 2024 | 2 | — | 0 | 8,565 |
| 2025 | 6 | 30 | 0 | 3,487 |
| 2026 | 2 | — | 0 | — |
https://510kreport.com/device/K905655 · printed Nov 6, 2026
Cite this page
510(k) Report. “K905655: Nonabsorbable Polypropylene Surgical Mesh.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K905655
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026