510(k) Report

510(k) · Cleared

Cleared

Stealth Monitor, Stealth Docking Cable, Stealth DSD Software Installation Disk, Stealth System

K142468510(k) TraditionalCleared Jul 11, 2015311-day reviewClass II21 CFR 870.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cardiac Insight, Inc. · DSH Recorder, Magnetic Tape, Medical

Cleared on Jul 11, 2015 as substantially equivalent to K042782 (Ge Medical Systems Information Technologies, 2005) and 2 other predicates after a 311-day review. Its family tree reaches back 6 generations to 1997.

Decided
Jul 11, 2015
Review
311 days
Class
Class II
Product code
DSH
Recalls
None
Predicates
3

Its longest line of descent runs back 6 generations to K963725 (1997). 18 ancestors in all, the oldest K882818 (1989). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2013: 1 other ancestor2005: 1 other ancestor2002: 2 other ancestors1989: 1 other ancestor2014: 1 other ancestor2006: 1 other ancestor1991: 1 other ancestor2001: 1 other ancestor1999: 1 other ancestor1997: 1 other ancestor1992: 1 other ancestorK963725 · Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device (Modified) · Card Guard, Ltd. · 1997K012223 · CG-2211 Selfcheck Ecg Transmitter · Card Guard Scientific Survival, Ltd. · 2001K042254 · PMP4 Selfcheck Ecg · Card Guard Scientific Survival, Ltd. · 2005K122184 · Ecg Check · Cardiac Designs, LLC · 2013K140933 · Alivecor Heart Monitor · AliveCor, Inc. · 2014 · recalledK142743 · AliveCor Heart Monitor · AliveCor, Inc. · 20151985199019952000200520102015
  1. Root · 6 generations backK963725 Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device…Card Guard, Ltd. · 1997
  2. 5 generations backK012223 CG-2211 Selfcheck Ecg TransmitterCard Guard Scientific Survival, Ltd. · 2001
  3. 4 generations backK042254 PMP4 Selfcheck EcgCard Guard Scientific Survival, Ltd. · 2005
  4. 3 generations backK122184 Ecg CheckCardiac Designs, LLC · 2013
  5. 2 generations backK140933 Alivecor Heart MonitorAliveCor, Inc. · 2014 · Recalled
  6. 1 generation backK142743 AliveCor Heart MonitorAliveCor, Inc. · 2015
  7. This deviceK142468 Stealth Monitor, Stealth Docking Cable, Stealth DSD Software…Cardiac Insight, Inc. · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K963725Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device (Modified)Card Guard, Ltd.1997—
−5K012223CG-2211 Selfcheck Ecg TransmitterCard Guard Scientific Survival, Ltd.2001—
−4K042254PMP4 Selfcheck EcgCard Guard Scientific Survival, Ltd.2005—
−3K122184Ecg CheckCardiac Designs, LLC2013—
−2K140933Alivecor Heart MonitorAliveCor, Inc.20141
−1K142743AliveCor Heart MonitorAliveCor, Inc.2015—
0 (this device)K142468Stealth Monitor, Stealth Docking Cable, Stealth DSD Software Installation…Cardiac Insight, Inc.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199110
199210
199710
199910
200110
200220
200510
200610
201310
201410
FIG. 1 — Lineage of K142468, 1997–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DSH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DSH device

  1. #1 K260157 LifeLens Physiological Monitorscore 17.9 · 22 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042782Seer MC
Summary page 4
…870.2800 2. Predicate Device Identification Device Name Clearance Number Product Code SEER MC K042782 MLO AliveCor Heart Monitor K142743 DXH, DPS Stealth™ System (M100…
Ge Medical Systems Information Technologies2005—
*K142743AliveCor Heart Monitor
Cleared while this submission was under review
Summary page 4
…Clearance Number Product Code SEER MC K042782 MLO AliveCor Heart Monitor K142743 DXH, DPS Stealth™ System (M100) K130288 DSH All predicates are Cl…
AliveCor, Inc.2015—
*K130288Stealth Monitor, Stealth Docking Cable, Stealth Display and Storage Device
Summary page 4
…K042782 MLO AliveCor Heart Monitor K142743 DXH, DPS Stealth™ System (M100) K130288 DSH All predicates are Class II devices. 3. Indications for Use and Device Description Indications…
Cardiac Insight, Inc.2013—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 3.3 years on median.
  • 1 of the 18 ancestors has a recall of any class.

How does its category compare?

All DSH devices

DSH Recorder, Magnetic Tape, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · DSH

4in 2025

2007: 12008: 12009: 32010: 22011: 62012: 22013: 22014: 12015: 22016: 22017: 32018: 32019: 32020: 42021: 42022: 42023: 62024: 22025: 42026 (partial year): 2
2007high 6 (2011) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DSH

205in 2025

2009: 84 days median2011: 64 days median2017: 91 days median2018: 269 days median2019: 30 days median2020: 122 days median2021: 263 days median2022: 427 days median2023: 198 days median2025: 205 days median
2007high 427 (2022) · low 30 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DSH

No recall names DSH since 2007.

Adverse event reports per year · DSH

213in 2025

2009: 12010: 82011: 32012: 12013: 22014: 32015: 82016: 62017: 312018: 302019: 762020: 912021: 1132022: 462023: 652024: 882025: 213
2007high 213 (2025) · low 0 (2007)2025

MAUDE reports naming product code DSH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
200938401
20102—08
201166403
20122—01
20132—02
20141—03
20152—08
20162—06
2017391031
20183269030
2019330076
20204122091
202142630113
20224427046
20236198065
20242—088
202542050213
20262—0—

What is it indicated for?

The Stealth™ Monitor is a prescription only single use, continuous recording ECG monitor that can be worn up to 168 hours (7 days) during activities of daily living. It is indicated for use on adult patients who may be asymptomatic or who may suffer from transient symptoms such as palpitations, dizziness, anxiety, fatigue, syncope, pre-syncope, light-headedness, shortness of breath and where a software-assisted analysis of the potential causes of these symptoms is desirable.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K142468: Stealth Monitor, Stealth Docking Cable, Stealth DSD Software Installation Disk, Stealth System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K142468

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026