510(k) · Cleared
ClearedRemington Medical Inc. Tuohy Epidural Needles
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Remington Medical, Inc. · BSP Needle, Conduction, Anesthetic (W/Wo Introducer)
Cleared on Jun 4, 2015 as substantially equivalent to K990519 (Myco Medical Supplies, Inc., 2000) and 1 other predicate after a 120-day review. Its family tree reaches back 8 generations to 1984. 3 of the 25 devices in its family, counting itself, have a Class I recall.
- Decided
- Jun 4, 2015
- Review
- 120 days
- Class
- Class II
- Product code
- BSP
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 8 generations to K840287 (1984). 24 ancestors in all, the oldest K801912 (1980). No later device cites it as a predicate yet. 3 of the 25 devices in this family, counting this one, have a Class I recall.
- Root · 8 generations backK840287 Brachial Plexus Anesthesia TrayBurron Medical Products, Inc. · 1984
- 7 generations backK013041 Plexolong SetsPajunk GmbH · 2002
- 6 generations backK023218 Modification to Plexolong SetsPajunk GmbH · 2003
- 5 generations backK033018 Stimulong Plus Catheter Set Model, VariousPajunk GmbH · 2004
- 4 generations backK063282 Contiplex Stim Continuous Nerve Block SetB.Braun Medical, Inc. · 2007
- 3 generations backK090995 B. Braun Contiplex Continuous Nerve Block SetB.Braun Medical, Inc. · 2009
- 2 generations backK113059 Contiplex FXB.Braun Medical, Inc. · 2012
- 1 generation backK133632 Perican UltraB.Braun Medical, Inc. · 2014
- This deviceK150266 Remington Medical Inc. Tuohy Epidural NeedlesRemington Medical, Inc. · 2015
Class I recalls in this family
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −8 | K840287 | Brachial Plexus Anesthesia Tray | Burron Medical Products, Inc. | 1984 | — |
| −7 | K013041 | Plexolong Sets | Pajunk GmbH | 2002 | — |
| −6 | K023218 | Modification to Plexolong Sets | Pajunk GmbH | 2003 | — |
| −5 | K033018 | Stimulong Plus Catheter Set Model, Various | Pajunk GmbH | 2004 | — |
| −4 | K063282 | Contiplex Stim Continuous Nerve Block Set | B.Braun Medical, Inc. | 2007 | — |
| −3 | K090995 | B. Braun Contiplex Continuous Nerve Block Set | B.Braun Medical, Inc. | 2009 | — |
| −2 | K113059 | Contiplex FX | B.Braun Medical, Inc. | 2012 | — |
| −1 | K133632 | Perican Ultra | B.Braun Medical, Inc. | 2014 | — |
| 0 (this device) | K150266 | Remington Medical Inc. Tuohy Epidural Needles | Remington Medical, Inc. | 2015 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1980 | 1 | 1 |
| 1983 | 1 | 0 |
| 1991 | 1 | 1 |
| 1992 | 2 | 1 |
| 1993 | 2 | 0 |
| 1995 | 1 | 0 |
| 1996 | 1 | 0 |
| 2000 | 3 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2012 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new BSP device
- #1 K241954 SonoBlock; SonoBlock IIscore 11.0 · 1 generation · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K990519 | Phoenix Epidural & Spinal NeedlesSummary page 4…Class II Legally Marketed Devices to Which Substantial Equivalence is Claimed: Myco Medical Supplies, Inc. Dr. Japan’s Phoenix Epidural & Spinal Needles, (K990519) B. Braun Medical, Inc. Perican™ Ultra Needle, (K133632) Description of the Device: The Tuohy Epidural Needle is a de… | 2000 |
| * | K133632 | Perican UltraSummary page 4…l Equivalence is Claimed: Myco Medical Supplies, Inc. Dr. Japan’s Phoenix Epidural & Spinal Needles, (K990519) B. Braun Medical, Inc. Perican™ Ultra Needle, (K133632) Description of the Device: The Tuohy Epidural Needle is a device used for the injection of anesthetic agents into a… | 2014 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (3 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K911202Atraumatic Standard Sprotte NeedlePajunk GmbH · 1992 · 4 generations back · ◆ in the 1992 ancestors bar of FIG. 11 Class I recall
- K911260Atraumatic Standard Sprotte NeedlePajunk GmbH · 1991 · 4 generations back · ◆ in the 1991 ancestors bar of FIG. 11 Class I recall
- K801912Arrow Positive Placement Con/Epidural anArrow Intl., Inc. · 1980 · 7 generations back · ◆ in the 1980 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 31 years and passes through 4 companies; a new generation was cleared every 2.4 years on median.
- 5 of the 24 ancestors have a recall of any class; 3 have a Class I recall.
- 1 other device also cites its predicate K990519.
How does its category compare?
All BSP devicesBSP Needle, Conduction, Anesthetic (W/Wo Introducer): FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.
FDA decisions per year · BSP
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · BSP
170in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · BSP
1in 2020
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · BSP
86in 2025
MAUDE reports naming product code BSP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 189 | 0 | 26 |
| 2008 | 8 | 127 | 0 | 24 |
| 2009 | 5 | 97 | 0 | 30 |
| 2010 | 3 | 79 | 0 | 49 |
| 2011 | 3 | 114 | 0 | 33 |
| 2012 | 3 | 148 | 0 | 20 |
| 2013 | 2 | — | 0 | 32 |
| 2014 | 2 | — | 0 | 41 |
| 2015 | 2 | — | 0 | 38 |
| 2016 | 6 | 268 | 1 | 152 |
| 2017 | 4 | 186 | 0 | 34 |
| 2018 | 8 | 241 | 0 | 69 |
| 2019 | 2 | — | 1 | 86 |
| 2020 | 3 | 269 | 1 | 78 |
| 2021 | 3 | 265 | 0 | 52 |
| 2022 | 2 | — | 0 | 84 |
| 2023 | 0 | — | 0 | 75 |
| 2024 | 3 | 70 | 0 | 66 |
| 2025 | 4 | 170 | 0 | 86 |
| 2026 | 0 | — | 1 (1) | — |
What is it indicated for?
Remington Medical, Inc. Tuohy Epidural Needles are to be used to inject local anesthetics into a patient to provide
regional anesthesia or to facilitate the placement of an epidural catheter.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K150266 · printed Nov 6, 2026
Cite this page
510(k) Report. “K150266: Remington Medical Inc. Tuohy Epidural Needles.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150266
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026