Burron Medical Products, Inc. · CAZ Anesthesia Conduction Kit

Cleared on Feb 23, 1984 after a 30-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 2 of the 49 devices in its family, counting itself, have a Class I recall. 48 later devices descend from it.

Decided
Feb 23, 1984
Review
30 days
Class
Class II
Product code
CAZ
Recalls
None
Predicates
0

48 later devices descend from it, 3 citing it directly. 2 of the 49 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2002: 3 descendants cleared2007: 3 descendants cleared2005: 3 descendants cleared2004: 4 descendants cleared2006: 3 descendants cleared2003: 4 descendants cleared2008: 2 descendants cleared2012: 6 descendants cleared, 2 with a Class I recall22018: 3 descendants cleared2017: 1 descendant cleared2020: 3 descendants cleared2016: 3 descendants cleared2010: 3 descendants cleared2009: 1 descendant cleared2014: 2 descendants cleared2022: 1 descendant cleared2023: 1 descendant cleared2024: 1 descendant cleared2015: 1 descendant cleared19801990200020102020
  1. This deviceK840287 Brachial Plexus Anesthesia TrayBurron Medical Products, Inc. · 1984
  2. Descendant · cites it directly · 32 of its ownK021567 Stimucath Continuous Nerve Block Set, Product Number AB-05000Arrow Intl., Inc. · 2002 · Recalled
  3. Descendant · cites it directly · 32 of its ownK013041 Plexolong SetsPajunk GmbH · 2002
  4. Descendant · 2 generations on · 29 of its ownK030937 Stimucath Continuous Nerve Block Set, Models AB-02030, AB-02060…Arrow International, Inc. · 2003 · Recalled
  5. Descendant · 2 generations on · 25 of its ownK023218 Modification to Plexolong SetsPajunk GmbH · 2003
  6. Descendant · 2 generations on · 23 of its ownK033018 Stimulong Plus Catheter Set Model, VariousPajunk GmbH · 2004

Showing 5 of 48 descendants. See all descendants

Descendants cleared per year

2002: 32003: 42004: 42005: 32006: 32007: 32008: 22009: 12010: 32012: 62014: 22015: 12016: 32017: 12018: 32020: 32022: 12023: 12024: 1
2002high 6 (2012) · low 0 (2011)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 48 · See all
  • K021567Stimucath Continuous Nerve Block Set, Product Number AB-05000Arrow Intl., Inc. · 2002 · cites it directly32descendants
  • K013041Plexolong SetsPajunk GmbH · 2002 · cites it directly32descendants
  • K030937Stimucath Continuous Nerve Block Set, Models AB-02030, AB-02060, AB-02090, AB-02030-PK…Arrow International, Inc. · 2003 · 2 generations on29descendants
  • K023218Modification to Plexolong SetsPajunk GmbH · 2003 · 2 generations on25descendants
  • K033018Stimulong Plus Catheter Set Model, VariousPajunk GmbH · 2004 · 2 generations on23descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K840287Brachial Plexus Anesthesia TrayBurron Medical Products, Inc.1984—
+1K021567Stimucath Continuous Nerve Block Set, Product Number AB-05000Arrow Intl., Inc.20022
+1K013041Plexolong SetsPajunk GmbH2002—
+2K030937Stimucath Continuous Nerve Block Set, Models AB-02030, AB-02060, AB-02090…Arrow International, Inc.20031
+2K023218Modification to Plexolong SetsPajunk GmbH2003—
+2K033018Stimulong Plus Catheter Set Model, VariousPajunk GmbH2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200230
200340
200440
200530
200630
200730
200820
200910
201030
201262
201420
201510
201630
201710
201830
202030
202210
202310
202410
FIG. 1 — Lineage of K840287, 1984–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAZ device

  1. #1 K261372 Profoject™ LOR Syringescore 12.4 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (48)

See all 48

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K021567Stimucath Continuous Nerve Block Set, Product Number AB-05000Arrow Intl., Inc.200232
K013041Plexolong SetsPajunk GmbH200232
K022019Perifix Catheter ConnectorB.Braun Medical, Inc.20025

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K121403Continuous Peripheral Nerve Block Catheter Kit and SetTeleflex, Inc. · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K122027Arrow Flexblock Continuous Peripheral Nerve Block CatheterArrow International, Inc. · 2012 · 4 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K021567 (Arrow Intl., Inc., 2002) has gone furthest, with 32 descendants of its own.

How does its category compare?

All CAZ devices

CAZ Anesthesia Conduction Kit: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CAZ

1in 2023

2007: 42008: 42009: 22010: 22011: 12012: 92015: 12016: 22019: 12020: 12021: 12022: 12023: 12026 (partial year): 1
2007high 9 (2012) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAZ

108in 2012

2007: 172 days median2008: 99 days median2012: 108 days median
2007high 172 (2007) · low 99 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CAZ

1in 2024

2009: 292010: 82011: 22013: 122014: 22015: 12016: 12024: 12026 (partial year): 12, 11 Class I
2007high 29 (2009) · low 0 (2007)2026

Class I (11 since 2007) Class II/III not classified

Adverse event reports per year · CAZ

137in 2025

2007: 812008: 802009: 1342010: 1392011: 1872012: 1872013: 2762014: 2512015: 2352016: 3722017: 3532018: 4482019: 4722020: 2742021: 1652022: 2702023: 602024: 1652025: 137
2007high 472 (2019) · low 60 (2023)2025

MAUDE reports naming product code CAZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074172081
2008499080
20092—29134
20102—8139
20111—2187
201291080187
20130—12276
20140—2251
20151—1235
20162—1372
20170—0353
20180—0448
20191—0472
20201—0274
20211—0165
20221—0270
20231—060
20240—1165
20250—0137
20261—12 (11)—
Cite this page

510(k) Report. “K840287: Brachial Plexus Anesthesia Tray.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K840287

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026