510(k) Report

510(k) · Cleared

Cleared

EUM 100Pro

K150398510(k) TraditionalCleared Aug 6, 2015169-day reviewClass II21 CFR 884.2740

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ob Tools, Ltd. · HGM System, Monitoring, Perinatal

Cleared on Aug 6, 2015 as substantially equivalent to K101801 (Monica Healthcare, 2011) after a 169-day review. Its family tree reaches back 3 generations to 1990.

Decided
Aug 6, 2015
Review
169 days
Class
Class II
Product code
HGM
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K900480 (1990). No later device cites it as a predicate yet.

  1. Root · 3 generations backK900480 M1350A Fetal Monitor (Intrapartum)Hewlett-Packard Co. · 1990
  2. 2 generations backK954351 Series 50XMHewlett-Packard GmbH · 1996
  3. 1 generation backK101801 Monica AN24Monica Healthcare · 2011
  4. This deviceK150398 EUM 100ProOb Tools, Ltd. · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K900480M1350A Fetal Monitor (Intrapartum)Hewlett-Packard Co.1990—
−2K954351Series 50XMHewlett-Packard GmbH1996—
−1K101801Monica AN24Monica Healthcare2011—
0 (this device)K150398EUM 100ProOb Tools, Ltd.2015—
FIG. 1 — Lineage of K150398, 1990–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HGM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HGM device

  1. #1 K241882 Fetal & Maternal Monitor (F15A, F15A Air)score 19.5 · 33 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K101801Monica AN24
Summary page 4
…ing system and accessories HGM - 21 CFR 884.2740 Class II Predicate Device: K101801 – Monica Healthcare – AN24 Reference Device: K131889 – OB Tools EUM 100Pro Device Description: The EUM100Pro…
Monica Healthcare2011—
†K131889Eum 100PROPromedic, Inc.2014—
†K991905Corometrics Model 171 and 172 Fetal MonitorGeneral Electric Medical Systems Information Techn1999—
†K990356The Bagnoli-8 Emg SystemDelsys, Inc.1999—

Also cleared against K101801: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 5.7 years on median.
  • None of the 3 ancestors has a recall.
  • 3 other devices also cite its predicate K101801.

How does its category compare?

All HGM devices

HGM System, Monitoring, Perinatal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · HGM

4in 2025

2007: 32008: 42009: 42010: 42011: 132012: 42013: 22014: 42015: 52016: 12017: 32018: 32020: 12022: 12023: 22024: 12025: 42026 (partial year): 2
2007high 13 (2011) · low 0 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HGM

269in 2025

2007: 56 days median2008: 75 days median2009: 66 days median2010: 193 days median2011: 141 days median2012: 107 days median2014: 231 days median2015: 169 days median2017: 138 days median2018: 258 days median2025: 269 days median
2007high 269 (2025) · low 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HGM

5in 2019

2008: 42009: 62013: 12014: 12019: 52026 (partial year): 2
2007high 6 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HGM

99in 2025

2007: 352008: 172009: 422010: 642011: 832012: 442013: 162014: 302015: 442016: 172017: 272018: 302019: 412020: 192021: 712022: 872023: 692024: 1742025: 99
2007high 174 (2024) · low 16 (2013)2025

MAUDE reports naming product code HGM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007356035
2008475417
2009466642
20104193064
201113141083
20124107044
20132—116
20144231130
20155169044
20161—017
20173138027
20183258030
20190—541
20201—019
20210—071
20221—087
20232—069
20241—0174
20254269099
20262—2—

What is it indicated for?

The EUM100Pro (Electro Uterine Monitor) is a transabdominal electromyography (EMG) monitor intended to non-invasively measure intrapartum uterine activity and fetal heart rate (FHR). The EUM100Pro acquires the signal from surface EMG electrodes placed on the patient abdomen.

The EUM100Pro is intended for use on women (>36 completed weeks of gestation) in labor, with singleton pregnancies.

The EUM100Pro is intended for use by healthcare professionals in a clinical setting.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K150398: EUM 100Pro.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150398

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026