Cholesterol

K150654510(k) TraditionalCleared Sep 29, 2015200-day reviewClass I21 CFR 862.1175

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Randox Laboratories, Ltd. · CHH Enzymatic Esterase--Oxidase, Cholesterol

Cleared on Sep 29, 2015 as substantially equivalent to K923504 (Randox Laboratories, Ltd., 1994) after a 200-day review. Its family tree reaches back 1 generation to 1994.

Decided
Sep 29, 2015
Review
200 days
Class
Class I
Product code
CHH
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K923504 (1994). No later device cites it as a predicate yet.

  1. Root · 1 generation backK923504 Cholesterol Enzymatic EndpointRandox Laboratories, Ltd. · 1994 · Recalled
  2. This deviceK150654 CholesterolRandox Laboratories, Ltd. · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K923504Cholesterol Enzymatic EndpointRandox Laboratories, Ltd.19943
0 (this device)K150654CholesterolRandox Laboratories, Ltd.2015—
FIG. 1 — Lineage of K150654, 1994–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CHH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CHH device

  1. #1 K251091 Lipidsscore 10.9 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K923504Cholesterol Enzymatic Endpoint
Summary page 5
…== Page 5 === 4. PREDICATE DEVICE PROPRIETARY NAMES AND 510 (k) NUMBERS Predicate Device Proprietary Name: Randox Laboratories Ltd, Cholesterol reagent 510 (k) Number: K923504 5. INTENDED USE For the quantitative in vitro determination of Cholesterol in serum and plasma. Cholesterol measurements are u…
Randox Laboratories, Ltd.19943
†K942458Precision-Multi-Sera - Human - Normal and ElevatedRandox Laboratories, Ltd.19953
†K053153Randox Calibration SerumRandox Laboratories, Ltd.20066

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.

How does its category compare?

All CHH devices

CHH Enzymatic Esterase--Oxidase, Cholesterol: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · CHH

1in 2025

2007: 22008: 22009: 12011: 12012: 42013: 12014: 12015: 12016: 12017: 12018: 22019: 12022: 12024: 12025: 1
2007high 4 (2012) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CHH

198in 2012

2012: 198 days median
2007high 198 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CHH

2in 2021

2009: 32010: 22013: 12014: 12016: 22021: 22026 (partial year): 1
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CHH

14in 2025

2007: 12010: 102011: 182012: 112014: 12016: 52017: 22018: 12019: 52020: 12021: 22022: 42023: 42024: 82025: 14
2007high 18 (2011) · low 0 (2008)2025

MAUDE reports naming product code CHH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—01
20082—00
20091—30
20100—210
20111—018
20124198011
20131—10
20141—11
20151—00
20161—25
20171—02
20182—01
20191—05
20200—01
20210—22
20221—04
20230—04
20241—08
20251—014
20260—1—

What is it indicated for?

For the quantitative in vitro determination of Cholesterol in serum and plasma. Cholesterol measurements are used in the

diagnosis and treatments of disorders involving excess cholesterol in the blood and lipid and lipoprotein metabolism

disorders.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K150654: Cholesterol.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150654

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026