Amplichek I, Negative , Amplichek I, Level 1, Amplichek I, Level 2, Amplichek I, Level 3, Amplichek I, MiniPak

K152679510(k) TraditionalCleared May 10, 2016235-day reviewClass II21 CFR 866.3920

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bio-Rad Laboratories · PMN Assayed External Control Material For Microbiology Nucleic Acid Amplification (Nat) Assays

Cleared on May 10, 2016 as substantially equivalent to DEN150058 (Bio-Rad Laboratories, 2016) after a 235-day review. Its family tree reaches back 1 generation to 2016.

Decided
May 10, 2016
Review
235 days
Class
Class II
Product code
PMN
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to DEN150058 (2016). No later device cites it as a predicate yet.

  1. Root · 1 generation backDEN150058 Amplichek II, Negative and Amplichek II, Negative MiniPak, Amplichek…Bio-Rad Laboratories · 2016
  2. This deviceK152679 Amplichek I, Negative , Amplichek I, Level 1, Amplichek I, Level 2…Bio-Rad Laboratories · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1DEN150058Amplichek II, Negative and Amplichek II, Negative MiniPak, Amplichek II, Level…Bio-Rad Laboratories2016—
0 (this device)K152679Amplichek I, Negative , Amplichek I, Level 1, Amplichek I, Level 2, Amplichek…Bio-Rad Laboratories2016—
FIG. 1 — Lineage of K152679, 2016–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PMN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PMN device

  1. #1 K251526 FilmArray GI Control Panel M238score 13.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN150058Amplichek II, Negative and Amplichek II, Negative MiniPak, Amplichek II, Level 1 and…
Summary page 4
…to Which Substantial Equivalence is Claimed Amplichek II Bio-Rad Laboratories 9500 Jeronimo Road, Irvine, California 92618-2017 DEN150058 4.0 Description of Device Amplichek I is a set of quality controls consisting of four levels filled in individual…
Bio-Rad Laboratories2016—

Also cleared against DEN150058: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 3 other devices also cite its predicate DEN150058.

How does its category compare?

All PMN devices

PMN Assayed External Control Material For Microbiology Nucleic Acid Amplification (Nat) Assays: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · PMN

1in 2025

2016: 32017: 22018: 32019: 62020: 22021: 12022: 32023: 42024: 22025: 12026 (partial year): 6
2007high 6 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PMN

90in 2023

2018: 59 days median2019: 71 days median2022: 582 days median2023: 90 days median2026 (partial year): 85 days median
2007high 582 (2022) · low 59 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PMN

1in 2019

2019: 1
2007high 1 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PMN

1in 2023

2023: 1
2007high 1 (2023) · low 0 (2007)2025

MAUDE reports naming product code PMN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20163—00
20172—00
201835900
201967110
20202—00
20211—00
2022358200
202349001
20242—00
20251—00
20266850—

What is it indicated for?

Amplichek I is intended for use as an external assayed quality control material to monitor the performance of in vitro laboratory nucleic acid testing procedures for the quantitative detection of Human Immunodeficiency Virus Type 1 (HIV-1), Hepatitis B Virus (HBV) and Hepatitis C Virus (HCV) for molecular diagnostic platforms listed in the package insert. This product is not intended to replace manufacturer controls provided with the device.

This product is not intended for use with blood donor screening assays in U.S. or Canada.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K152679: Amplichek I, Negative , Amplichek I, Level 1, Amplichek I, Level 2, Amplichek I, Level 3, Amplichek I, MiniPak.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K152679

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026