510(k) Report

510(k) · Cleared

Cleared

Diego Elite Drill

K152744510(k) TraditionalCleared Jun 10, 2016261-day reviewClass II21 CFR 874.4250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Gyrus Acmi, Inc. · ERL Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece

Cleared on Jun 10, 2016 as substantially equivalent to K034004 (Gyrus Ent LLC, 2004) after a 261-day review. Its family tree reaches back 10 generations to 1994.

Decided
Jun 10, 2016
Review
261 days
Class
Class II
Product code
ERL
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K936109 (1994). 72 ancestors in all, the oldest K800617 (1980). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2003: 1 other ancestor2002: 5 other ancestors2000: 12 other ancestors2001: 3 other ancestors1998: 6 other ancestors1997: 4 other ancestors1996: 8 other ancestors1995: 7 other ancestors1994: 4 other ancestors1992: 3 other ancestors1999: 1 other ancestor1980: 1 other ancestor1993: 1 other ancestor1991: 3 other ancestors1990: 1 other ancestor1989: 1 other ancestor1986: 1 other ancestorReference device: K081277 · XPS 4000 System, Midas Rex Legend Ehs System, Integrated Power CONS0LE (Ipc) · Medtronic Xomed, Inc. · 2008 · recalledReference device: K123429 · Olympus Energy Power System (Eps) · Gyrus Acmi, Inc. · 2013 · recalledK936109 · Sharplan Model 1120 CO2 Surgical Laser · Sharplan Lasers, Inc. · 1994K960521 · Sharplan Lasers, Inc. Silktouch Flash Scanner · Sharplan Lasers, Inc. · 1996K963339 · Coherent Ultrapulse CO2 Surgical Lasers · Coherent Medical Group · 1997K974789 · Coherent Ultrapulse S Series CO2 Surgical Lasers Model C and L · Lumenis, Inc. · 1998K990947 · Modified Versapulse Select Single Wavelength, HO: Yag and Dual Wavelength, HO: Yag/ND: Yag Surgical Lasers and Delivery · Lumenis, Inc. · 1999K011703 · Lumenis Versapulse Powersuite Holmium (HO:Yag) and Dual Wavelength (HO:Yag/ND:Yag) Surgical Lasers and Delivery Devices · Lumenis · 2001 · recalled×2: 2 generations cleared close together, K014290 (2002), K021364 (2002) K030108 · Arthrocare Ent Coblator Surgery System · Arthrocare Corp. · 2003 · recalledK034004 · Diego RF Powered Dissector and Drill System Console · Gyrus Ent LLC · 20041980199020002010
  1. Root · 10 generations backK936109 Sharplan Model 1120 CO2 Surgical LaserSharplan Lasers, Inc. · 1994
  2. 6 generations between
  3. 3 generations backK021364 Modification to Entec Plasma WandsArthrocare Corp. · 2002
  4. 2 generations backK030108 Arthrocare Ent Coblator Surgery SystemArthrocare Corp. · 2003 · Recalled
  5. 1 generation backK034004 Diego RF Powered Dissector and Drill System ConsoleGyrus Ent LLC · 2004
  6. This deviceK152744 Diego Elite DrillGyrus Acmi, Inc. · 2016
Show all 10 generations
  1. Root · 10 generations backK936109 Sharplan Model 1120 CO2 Surgical LaserSharplan Lasers, Inc. · 1994
  2. 9 generations backK960521 Sharplan Lasers, Inc. Silktouch Flash ScannerSharplan Lasers, Inc. · 1996
  3. 8 generations backK963339 Coherent Ultrapulse CO2 Surgical LasersCoherent Medical Group · 1997
  4. 7 generations backK974789 Coherent Ultrapulse S Series CO2 Surgical Lasers Model C and LLumenis, Inc. · 1998
  5. 6 generations backK990947 Modified Versapulse Select Single Wavelength, HO: Yag and Dual…Lumenis, Inc. · 1999
  6. 5 generations backK011703 Lumenis Versapulse Powersuite Holmium (HO:Yag) and Dual Wavelength…Lumenis · 2001 · Recalled
  7. 4 generations backK014290 Entec Plasma WandsArthrocare Corp. · 2002
  8. 3 generations backK021364 Modification to Entec Plasma WandsArthrocare Corp. · 2002
  9. 2 generations backK030108 Arthrocare Ent Coblator Surgery SystemArthrocare Corp. · 2003 · Recalled
  10. 1 generation backK034004 Diego RF Powered Dissector and Drill System ConsoleGyrus Ent LLC · 2004
  11. This deviceK152744 Diego Elite DrillGyrus Acmi, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K936109Sharplan Model 1120 CO2 Surgical LaserSharplan Lasers, Inc.1994—
−9K960521Sharplan Lasers, Inc. Silktouch Flash ScannerSharplan Lasers, Inc.1996—
−8K963339Coherent Ultrapulse CO2 Surgical LasersCoherent Medical Group1997—
−7K974789Coherent Ultrapulse S Series CO2 Surgical Lasers Model C and LLumenis, Inc.1998—
−6K990947Modified Versapulse Select Single Wavelength, HO: Yag and Dual Wavelength, HO…Lumenis, Inc.1999—
−5K011703Lumenis Versapulse Powersuite Holmium (HO:Yag) and Dual Wavelength…Lumenis20012
−4K014290Entec Plasma WandsArthrocare Corp.2002—
−3K021364Modification to Entec Plasma WandsArthrocare Corp.2002—
−2K030108Arthrocare Ent Coblator Surgery SystemArthrocare Corp.20031
−1K034004Diego RF Powered Dissector and Drill System ConsoleGyrus Ent LLC2004—
0 (this device)K152744Diego Elite DrillGyrus Acmi, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
198610
198910
199010
199130
199230
199310
199440
199570
199680
199740
199860
199910
2000120
200130
200250
200310
FIG. 1 — Lineage of K152744, 1994–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ERL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ERL device

  1. #1 K243280 Piezomed Pro (Piezomed Pro module M-PM100…score 12.0 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K034004Diego RF Powered Dissector and Drill System Console
Summary page 5
…Burs, Instrument Tray Predicate Devices Gyrus ACMI Diego® RF Powered Dissector & Drill System: K034004 Reference Predicates: Medtronic Midas Rex: K081277 Gyrus ACMI Diego E…
Gyrus Ent LLC2004—
†K081277XPS 4000 System, Midas Rex Legend Ehs System, Integrated Power CONS0LE (Ipc)Medtronic Xomed, Inc.20081
†K123429Olympus Energy Power System (Eps)Gyrus Acmi, Inc.201312

Also cleared against K034004: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 7 companies; a new generation was cleared every 1.1 years on median.
  • 5 of the 72 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K034004.

How does its category compare?

All ERL devices

ERL Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · ERL

1in 2025

2008: 62009: 12012: 22013: 22014: 12015: 32016: 42017: 22018: 12019: 12020: 12021: 12022: 32024: 12025: 1
2007high 6 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ERL

191in 2022

2008: 181 days median2015: 86 days median2016: 180 days median2022: 191 days median
2007high 191 (2022) · low 86 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ERL

1in 2021

2009: 12013: 32020: 52021: 1
2007high 5 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ERL

1,469in 2025

2007: 1122008: 602009: 2492010: 4442011: 1,0682012: 1,3792013: 3,2312014: 1,9752015: 2,6302016: 1,4552017: 9992018: 1,3802019: 2,5152020: 2,3692021: 2,2832022: 1,5742023: 1,7252024: 1,5882025: 1,469
2007high 3,231 (2013) · low 60 (2008)2025

MAUDE reports naming product code ERL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—0112
20086181060
20091—1249
20100—0444
20110—01,068
20122—01,379
20132—33,231
20141—01,975
201538602,630
2016418001,455
20172—0999
20181—01,380
20191—02,515
20201—52,369
20211—12,283
2022319101,574
20230—01,725
20241—01,588
20251—01,469
20260—0—

What is it indicated for?

The Diego Elite Drill is intended for cutting, drilling, and removal of bone, and soft and hard tissue in general ENT, and Otoneurologic procedures when used in conjunction with the Diego Elite console.

Specific procedures would include Mastoid/Neurotology (Mastoidectomy / Mastoidotomy) and Stapes procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K152744: Diego Elite Drill.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K152744

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026