510(k) Report

510(k) · Cleared

Recalled · Class II · 2021

Merge Hemo

K152864510(k) TraditionalCleared Apr 7, 2016190-day reviewClass II21 CFR 870.1425Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Merge Healthcare Incorporated · DQK Computer, Diagnostic, Programmable

Cleared on Apr 7, 2016 as substantially equivalent to K130626 (Ge Medical Systems Information Technologies, Inc., 2013) and 1 other predicate after a 190-day review. Its family tree reaches back 7 generations to 2000. 1 later device descends from it. It has been recalled 2 times.

Decided
Apr 7, 2016
Review
190 days
Class
Class II
Product code
DQK
Recalls
2
Predicates
2

Its longest line of descent runs back 7 generations to K001305 (2000). 8 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 7 generations backK001305 Mac-Lab System and Cardiolab EP SystemGeneral Electric Medical Systems Information Techn · 2000
  2. 6 generations backK021366 Mac-Lab/Cardiolab EP/CombolabGeneral Electric Medical Systems Information Techn · 2002 · Recalled
  3. 5 generations backK032577 Modification to: Mac-Lab/Cardiolab EP/Combolab SystemGe Medical Systems Information Technologies · 2003
  4. 4 generations backK050093 Mac-Lab/Cardiolab EP/Combolab SystemGe Medical Systems Information Technologies · 2005 · Recalled
  5. 3 generations backK061741 Mac-Lab/Cardiolab /Combolab/Specialslab SystemGE Healthcare · 2006
  6. 2 generations backK111200 Mac-Lab System, Cardiolab System, Combolab System, Specialslab SystemGE Healthcare · 2011
  7. 1 generation backK130626 Mac-Lab Hemodynamic Recording System; Cardiolab Electrophysiology…Ge Medical Systems Information Technologies, Inc. · 2013 · Recalled
  8. This deviceK152864 Merge HemoMerge Healthcare Incorporated · 2016
  9. Descendant · cites it directly · 0 of its ownK233326 Merge Hemo, Model RCSV2Merge Healthcare Incorporated · 2024 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K233326Merge Hemo, Model RCSV2Merge Healthcare Incorporated · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K001305Mac-Lab System and Cardiolab EP SystemGeneral Electric Medical Systems Information Techn2000—
−6K021366Mac-Lab/Cardiolab EP/CombolabGeneral Electric Medical Systems Information Techn20021
−5K032577Modification to: Mac-Lab/Cardiolab EP/Combolab SystemGe Medical Systems Information Technologies2003—
−4K050093Mac-Lab/Cardiolab EP/Combolab SystemGe Medical Systems Information Technologies20054
−3K061741Mac-Lab/Cardiolab /Combolab/Specialslab SystemGE Healthcare2006—
−2K111200Mac-Lab System, Cardiolab System, Combolab System, Specialslab SystemGE Healthcare2011—
−1K130626Mac-Lab Hemodynamic Recording System; Cardiolab Electrophysiology Recording…Ge Medical Systems Information Technologies, Inc.20131
0 (this device)K152864Merge HemoMerge Healthcare Incorporated2016—
+1K233326Merge Hemo, Model RCSV2Merge Healthcare Incorporated20241

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K152864, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQK device

  1. #1 K213682 HemoSphere Advanced Monitor, HemoSphere…score 26.7 · 28 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130626Mac-Lab Hemodynamic Recording System; Cardiolab Electrophysiology Recording System…
Summary page 4
…Programmable Diagnostic Computer (21 CFR 870.1425) Regulatory Class: II Product Code: DQK III. PREDICATE DEVICE GE Mac-Lab, CardioLab, ComboLab, SpecialsLab v6.9.5, K130626 (primary predicate) HeartSuite Hemodynamics, K082421 IV. DEVICE DESCRIPTION Merge Hemo is a hemodynamic recording and displ…
Ge Medical Systems Information Technologies, Inc.20131
*K082421Heartsuite Hemodynamics 7.10
Summary page 4
…gulatory Class: II Product Code: DQK III. PREDICATE DEVICE GE Mac-Lab, CardioLab, ComboLab, SpecialsLab v6.9.5, K130626 (primary predicate) HeartSuite Hemodynamics, K082421 IV. DEVICE DESCRIPTION Merge Hemo is a hemodynamic recording and display system designed to measure, record, and display vi…
Emageon, Inc.200811
†K132474Cardiovascular Pressure Measurement (CPM) System, Navvus CatheterAcist Medical Systems2014—

Also cleared against K130626: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K233326Merge Hemo, Model RCSV2Merge Healthcare Incorporated20240

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 23, 2021Class IIZ-2387-2021Under Investigation by firmThe firm identified a safety issue affecting the software associated with Merge Hemo versions 9.x and 10.x, used in combination with an HL7 lab interface.
Apr 6, 2017Class IIZ-0350-2018Component design/selectionMerge is conducting a hardware recall (replacement) of Fellows "Mighty 8" Power Strip and TrippLite Power Strip due to overheat of input resistor causing the power strip to smoke.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 1.6 years on median.
  • 4 of the 8 ancestors have a recall of any class.
  • Of its descendants, K233326 (Merge Healthcare Incorporated, 2024) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K130626.

How does its category compare?

All DQK devices

DQK Computer, Diagnostic, Programmable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DQK

23so far in 2026, the most since 2007

2007: 132008: 42009: 122010: 92011: 122012: 72013: 132014: 92015: 72016: 152017: 72018: 142019: 152020: 162021: 162022: 192023: 212024: 132025: 222026 (partial year): 23
2007high 23 (2026) · low 4 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQK

95in 2025

2007: 83 days median2008: 70 days median2009: 93 days median2010: 64 days median2011: 69 days median2012: 74 days median2013: 68 days median2014: 90 days median2015: 125 days median2016: 190 days median2017: 146 days median2018: 150 days median2019: 113 days median2020: 123 days median2021: 132 days median2022: 136 days median2023: 133 days median2024: 100 days median2025: 95 days median2026 (partial year): 151 days median
2007high 190 (2016) · low 64 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQK

1in 2025

2007: 42008: 12009: 22010: 32011: 22012: 32013: 12014: 42015: 22017: 22018: 62019: 12020: 12021: 12022: 22023: 22024: 242025: 12026 (partial year): 2
2007high 24 (2024) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQK

433in 2025

2007: 182008: 342009: 402010: 492011: 552012: 1292013: 1802014: 1152015: 1312016: 3402017: 2522018: 2612019: 2182020: 2152021: 3512022: 3192023: 3402024: 5572025: 433
2007high 557 (2024) · low 18 (2007)2025

MAUDE reports naming product code DQK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071383418
2008470134
20091293240
2010964349
20111269255
20127743129
201313681180
20149904115
201571252131
2016151900340
201771462252
2018141506261
2019151131218
2020161231215
2021161321351
2022191362319
2023211332340
20241310024557
202522951433
2026231512—

What is it indicated for?

Merge Hemo displays, measures, and records physiological data from a patient undergoing a cardiac catheterization procedure, The Hemo System can visualize and capture vital sign values including ECG, impedance respiration, SpO2 and Pleth waveforms, invasive blood pressure, temperature, non-invasive blood pressure (NIBP), Thermodilution cardiac output and Fractional Flow Reserve (FFR). The system can display and capture diagnostic quality 12 Lead resting…

Read the full statement (241 words)

Merge Hemo displays, measures, and records physiological data from a patient undergoing a cardiac catheterization procedure,

The Hemo System can visualize and capture vital sign values including ECG, impedance respiration, SpO2 and Pleth waveforms, invasive blood pressure, temperature, non-invasive blood pressure (NIBP), Thermodilution cardiac output and Fractional Flow Reserve (FFR). The system can display and capture diagnostic quality 12 Lead resting ECG to visualize arrhythmias, and ST-segment changes. Some Hemo systems have an option to measure and display Side-stream End Tidal Carbon Dioxide (EtCO2) along with apnea and respiration rates calculated from the EtCO2 waveform.

The hemodynamic portion of the system is comprised of the Patient Data Module (PDM) and the Merge Hemo Monitor PC. The two units are connected via a serial interface,

All vital parameters are acquired and calculated in the PDM. This data is then transmitted to the Merge Hemo Monitor PC via the serial interface. All data can then be displayed on the Merge Hemo Monitor PC. The Merge Hemo system is not intended to produce alarms for out-of-range conditions.

Patient allergies and current medication information can be entered by the user and displayed by the system. If desired and using a third party database the Hemo system can display drug to drug or drug to allergy interaction information.

The system is intended for use in hospital cardiac catheterization laboratories and in pre-and post-procedure care areas in the hospital under the close supervision of qualified medical personnel.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K152864: Merge Hemo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K152864

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026