K153071510(k) SpecialCleared Dec 23, 201562-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Micro Therapeutics, Inc. d/b/a ev3 Neurovascular · NRY Catheter, Thrombus Retriever

Cleared on Dec 23, 2015 as substantially equivalent to K123378 (Micro Therapeutics Dba Ev3 Neurovascular, 2012) and 2 other predicates after a 62-day review. Its family tree reaches back 8 generations to 2001. 10 later devices descend from it.

Decided
Dec 23, 2015
Review
62 days
Class
Class II
Product code
NRY
Recalls
None
Predicates
3

Its longest line of descent runs back 8 generations to K003410 (2001). 14 ancestors in all. 10 later devices descend from it, 4 citing it directly.

  1. Root · 8 generations backK003410 Concentric Retriever, Model 90030Concentric Medical, Inc. · 2001 · Recalled
  2. 7 generations backK030476 Modified Concentric Retriever, Model 90037Concentric Medical, Inc. · 2003 · Recalled
  3. 6 generations backK033736 Merci Retriever, Models 90065, 90066Concentric Medical, Inc. · 2004
  4. 5 generations backK063774 Modification to Merci Retriever, Models X5 and X6Concentric Medical, Inc. · 2007
  5. 4 generations backK090085 Merci Retriever, Models 90050, 90060, 90066, 90070, 90110, 90111…Concentric Medical, Inc. · 2009
  6. 3 generations backK113455 Solitaire FR Revascularization DeviceMicro Therapeutics Dba Ev3 Neurovascular · 2012
  7. 2 generations backK123378 Solitaire 2 Revascularization DeviceMicro Therapeutics Dba Ev3 Neurovascular · 2012
  8. 1 generation backK141491 Solitaire 2 Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2014
  9. This deviceK153071 Solitaire Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2015
  10. Descendant · cites it directly · 8 of its ownK160641 Solitaire Platinum Revascularization Device, 6x40 mmMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2017
  11. Descendant · cites it directly · 5 of its ownK161879 Solitaire Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2016
  12. Descendant · cites it directly · 3 of its ownK181186 Solitare Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2018
  13. Descendant · 2 generations on · 2 of its ownK211338 EMBOTRAP III Revascularization DeviceNeuravi, Ltd. · 2021
  14. Descendant · 2 generations on · 2 of its ownK183022 Solitaire 4 Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2019

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2016: 12017: 12018: 22019: 12020: 12021: 32025: 1
2016high 3 (2021) · low 0 (2022)2026

Most influential descendants

Showing 5 of 10 · See all
  • K160641Solitaire Platinum Revascularization Device, 6x40 mmMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2017 · cites it directly8descendants
  • K161879Solitaire Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2016 · cites it directly5descendants
  • K181186Solitare Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2018 · cites it directly3descendants
  • K211338EMBOTRAP III Revascularization DeviceNeuravi, Ltd. · 2021 · 2 generations on2descendants
  • K183022Solitaire 4 Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2019 · 2 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K003410Concentric Retriever, Model 90030Concentric Medical, Inc.20011
−7K030476Modified Concentric Retriever, Model 90037Concentric Medical, Inc.20032
−6K033736Merci Retriever, Models 90065, 90066Concentric Medical, Inc.2004—
−5K063774Modification to Merci Retriever, Models X5 and X6Concentric Medical, Inc.2007—
−4K090085Merci Retriever, Models 90050, 90060, 90066, 90070, 90110, 90111, 90112, 90113Concentric Medical, Inc.2009—
−3K113455Solitaire FR Revascularization DeviceMicro Therapeutics Dba Ev3 Neurovascular2012—
−2K123378Solitaire 2 Revascularization DeviceMicro Therapeutics Dba Ev3 Neurovascular2012—
−1K141491Solitaire 2 Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular2014—
0 (this device)K153071Solitaire Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular2015—
+1K160641Solitaire Platinum Revascularization Device, 6x40 mmMicro Therapeutics, Inc. d/b/a ev3 Neurovascular2017—
+1K161879Solitaire Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular2016—
+1K181186Solitare Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular2018—
+2K211338EMBOTRAP III Revascularization DeviceNeuravi, Ltd.2021—
+2K183022Solitaire 4 Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200610
200730
200820

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201710
201820
201910
202010
202130
202510
FIG. 1 — Lineage of K153071, 2001–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NRY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NRY device

  1. #1 K232971 APRO 55 Catheter and Alembic Aspiration Tubingscore 18.6 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K123378Solitaire 2 Revascularization Device
Summary page 4
…21 CFR 870.1250 – Class II Device: Product Code NRY Predicate Device: Solitaire™ 2 Revascularization Device 510(k)#: K123378 and K141491 Solitaire™ FR Revascularization Device (Biocompatibility) 510(k)#…
Micro Therapeutics Dba Ev3 Neurovascular2012—
*K141491Solitaire 2 Revascularization Device
Summary page 4
…870.1250 – Class II Device: Product Code NRY Predicate Device: Solitaire™ 2 Revascularization Device 510(k)#: K123378 and K141491 Solitaire™ FR Revascularization Device (Biocompatibility) 510(k)#: K113455 P…
Micro Therapeutics, Inc. d/b/a ev3 Neurovascular2014—
*K113455Solitaire FR Revascularization Device
Summary page 4
…510(k)#: K123378 and K141491 Solitaire™ FR Revascularization Device (Biocompatibility) 510(k)#: K113455 Performance Data: The following bench testing was performed in support of the Solitaire™ Platin…
Micro Therapeutics Dba Ev3 Neurovascular2012—

Also cleared against K123378: 1 other device →

What descends from it? (10)

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K160641Solitaire Platinum Revascularization Device, 6x40 mmMicro Therapeutics, Inc. d/b/a ev3 Neurovascular20178
K161879Solitaire Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular20165
K181186Solitare Platinum Revascularization DeviceMicro Therapeutics, Inc. d/b/a ev3 Neurovascular20183
K181060Solitaire 2 and Solitaire Platinum Revascularization DeviceMedtronic Neurovascular20180

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 1.9 years on median.
  • 3 of the 14 ancestors have a recall of any class.
  • Of its descendants, K160641 (Micro Therapeutics, Inc. d/b/a ev3 Neurovascular, 2017) has gone furthest, with 8 descendants of its own.
  • 1 other device also cites its predicate K123378.

How does its category compare?

All NRY devices

NRY Catheter, Thrombus Retriever: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · NRY

15in 2025

2007: 52008: 22009: 22010: 12011: 22012: 42014: 42015: 62016: 52017: 32018: 112019: 72020: 62021: 92022: 32023: 82024: 82025: 152026 (partial year): 14
2007high 15 (2025) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NRY

129in 2025

2007: 94 days median2012: 90 days median2014: 140 days median2015: 128 days median2016: 75 days median2017: 185 days median2018: 156 days median2019: 89 days median2020: 125 days median2021: 80 days median2022: 129 days median2023: 112 days median2024: 165 days median2025: 129 days median2026 (partial year): 147 days median
2007high 185 (2017) · low 75 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NRY

4in 2020

2010: 12013: 12017: 42020: 4, 4 Class I2026 (partial year): 2
2007high 4 (2017) · low 0 (2007)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · NRY

565in 2025

2007: 132008: 182009: 572010: 2892011: 2632012: 3662013: 4052014: 4282015: 5982016: 4972017: 4322018: 4152019: 6502020: 7032021: 6882022: 5492023: 7112024: 6412025: 565
2007high 711 (2023) · low 13 (2007)2025

MAUDE reports naming product code NRY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007594013
20082—018
20092—057
20101—1289
20112—0263
20124900366
20130—1405
201441400428
201561280598
20165750497
201731854432
2018111560415
20197890650
202061254 (4)703
20219800688
202231290549
202381120711
202481650641
2025151290565
2026141472—

What is it indicated for?

The Solitaire™ Platinum Revascularization Device is intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke within 8 hours of symptom onset. Patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV t-PA therapy are candidates for treatment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K153071: Solitaire Platinum Revascularization Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K153071

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026