Asahi Intecc Co., Ltd. · DQX Wire, Guide, Catheter

Cleared on Feb 25, 2016 as substantially equivalent to K103057 (Asahi Intecc Co., Ltd., 2010) and 1 other predicate after a 90-day review. Its family tree reaches back 10 generations to 1989. 14 later devices descend from it.

Decided
Feb 25, 2016
Review
90 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
2

Its longest line of descent runs back 10 generations to K890505 (1989). 27 ancestors in all. 14 later devices descend from it, 3 citing it directly.

  1. Root · 10 generations backK890505 Usci Grey/Black Guide WireC.R. Bard, Inc. · 1989
  2. 6 generations between
  3. 3 generations backK062186 Asahi Ptca Guide Wire, Fielder J, Model AGP140000J, AGP140300JAsahi Intecc Co., Ltd. · 2006
  4. 2 generations backK070945 Asahi Ptca Guide WireAsahi Intecc Co., Ltd. · 2008
  5. 1 generation backK103057 Asahi Astato XS 20 Peripheral Guide WireAsahi Intecc Co., Ltd. · 2010
  6. This deviceK153443 ASAHI Astato XS 40Asahi Intecc Co., Ltd. · 2016
  7. Descendant · cites it directly · 11 of its ownK163426 ASAHI PTCA, Peripheral, and Neurovascular Guide Wires, ASAHI Guide…Asahi Intecc Co., Ltd. · 2017
  8. Descendant · 2 generations on · 3 of its ownK203533 Vassallo GTFilmecc Co., Ltd. · 2021
  9. Descendant · 2 generations on · 1 of its ownK203529 VASSALLO GT HybridFilmecc Co., Ltd. · 2021
  10. Descendant · 2 generations on · 0 of its ownK243733 SION blue PLUSAsahi Intecc Co., Ltd. · 2025
  11. Descendant · 2 generations on · 0 of its ownK241962 CrossloopAsahi Intecc Co., Ltd. · 2025
Show all 10 generations
  1. Root · 10 generations backK890505 Usci Grey/Black Guide WireC.R. Bard, Inc. · 1989
  2. 9 generations backK961271 Usci Commander Series Guide WiresC.R. Bard, Inc. · 1996
  3. 8 generations backK990639 Acs HI-Torque Cross IT 100XT, 200XT and 300XT Guide Wires with…Guidant Corp. · 1999
  4. 7 generations backK022762 Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000…Jomed, Inc. · 2002
  5. 6 generations backK031277 Jowire Asahi Ptca Catheter Guide Wires, Models…Jomed, Inc. · 2003
  6. 5 generations backK032615 Asahi Ptca Catheter Guide Wires, Models AGH147000 and AGH147300Asahi Intecc Co., Ltd. · 2003
  7. 4 generations backK043422 Asahi Ptca Guide Wire, J Shape SeriesAsahi Intecc Co., Ltd. · 2005
  8. 3 generations backK062186 Asahi Ptca Guide Wire, Fielder J, Model AGP140000J, AGP140300JAsahi Intecc Co., Ltd. · 2006
  9. 2 generations backK070945 Asahi Ptca Guide WireAsahi Intecc Co., Ltd. · 2008
  10. 1 generation backK103057 Asahi Astato XS 20 Peripheral Guide WireAsahi Intecc Co., Ltd. · 2010
  11. This deviceK153443 ASAHI Astato XS 40Asahi Intecc Co., Ltd. · 2016

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2017: 12018: 12021: 22022: 22023: 42024: 12025: 3
2017high 4 (2023) · low 0 (2019)2026

Most influential descendants

Showing 5 of 14 · See all
  • K163426ASAHI PTCA, Peripheral, and Neurovascular Guide Wires, ASAHI Guide Wire ExtensionAsahi Intecc Co., Ltd. · 2017 · cites it directly11descendants
  • K203533Vassallo GTFilmecc Co., Ltd. · 2021 · 2 generations on3descendants
  • K203529VASSALLO GT HybridFilmecc Co., Ltd. · 2021 · 2 generations on1descendant
  • K243733SION blue PLUSAsahi Intecc Co., Ltd. · 2025 · 2 generations on0descendants
  • K241962CrossloopAsahi Intecc Co., Ltd. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K890505Usci Grey/Black Guide WireC.R. Bard, Inc.1989—
−9K961271Usci Commander Series Guide WiresC.R. Bard, Inc.1996—
−8K990639Acs HI-Torque Cross IT 100XT, 200XT and 300XT Guide Wires with Hydrocoat…Guidant Corp.1999—
−7K022762Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000, AG143000…Jomed, Inc.2002—
−6K031277Jowire Asahi Ptca Catheter Guide Wires, Models…Jomed, Inc.2003—
−5K032615Asahi Ptca Catheter Guide Wires, Models AGH147000 and AGH147300Asahi Intecc Co., Ltd.2003—
−4K043422Asahi Ptca Guide Wire, J Shape SeriesAsahi Intecc Co., Ltd.2005—
−3K062186Asahi Ptca Guide Wire, Fielder J, Model AGP140000J, AGP140300JAsahi Intecc Co., Ltd.2006—
−2K070945Asahi Ptca Guide WireAsahi Intecc Co., Ltd.2008—
−1K103057Asahi Astato XS 20 Peripheral Guide WireAsahi Intecc Co., Ltd.2010—
0 (this device)K153443ASAHI Astato XS 40Asahi Intecc Co., Ltd.2016—
+1K163426ASAHI PTCA, Peripheral, and Neurovascular Guide Wires, ASAHI Guide Wire…Asahi Intecc Co., Ltd.2017—
+2K203533Vassallo GTFilmecc Co., Ltd.2021—
+2K203529VASSALLO GT HybridFilmecc Co., Ltd.2021—
+2K243733SION blue PLUSAsahi Intecc Co., Ltd.2025—
+2K241962CrossloopAsahi Intecc Co., Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199420
199520
199710
199840
200420
200520
200610
200720

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
201810
202120
202220
202340
202410
202530
FIG. 1 — Lineage of K153443, 1989–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K103057Asahi Astato XS 20 Peripheral Guide Wire
Summary page 4
…Wire PRODUCT CODE DQX- Catheter Guide Wire PREDICATE DEVICES: Primary Predicate: ASAHI Astato XS 20 Peripheral Guide Wire (K103057) Secondary Predicate: ASAHI Astato 30 Peripheral Guide Wire (K071721)…
Asahi Intecc Co., Ltd.2010—
*K071721Asahi Astato 30 Peripheral Guide Wire, Models - PAGH18M071, PAGH18M371
Summary page 4
…ASAHI Astato XS 20 Peripheral Guide Wire (K103057) Secondary Predicate: ASAHI Astato 30 Peripheral Guide Wire (K071721) Reference Device: ASAHI RG3 (K141339) INTENDED USE/INDICATIONS FOR USE Thi…
Asahi Intecc Co., Ltd.2007—
†K141339Asahi RG3 Guidewire/Asahi RG3 Soft GuidewireAsahi Intecc Co., Ltd.2014—

Also cleared against K103057: 4 other devices →

What descends from it? (14)

See all 14

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K163426ASAHI PTCA, Peripheral, and Neurovascular Guide Wires, ASAHI Guide Wire ExtensionAsahi Intecc Co., Ltd.201711
K230377CROSSLEAD Penetration Peripheral Guide WireAsahi Intecc Co., Ltd.20230
K213834Cardio Flow Peripheral Guide WireCardio Flow Inc.,20220

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 4 companies; a new generation was cleared every 2.7 years on median.
  • 2 of the 27 ancestors have a recall of any class.
  • Of its descendants, K163426 (Asahi Intecc Co., Ltd., 2017) has gone furthest, with 11 descendants of its own.
  • 4 other devices also cite its predicate K103057.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

This product is intended to facilitate the placement and exchange of diagnostic and therapeutic devices during intravascular procedures. This device is intended for peripheral vascular use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K153443: ASAHI Astato XS 40.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K153443

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026