510(k) Report

510(k) · Cleared

Cleared

LD-Oxi system

K160956510(k) SpecialCleared Jul 6, 201692-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ld Technology, LLC · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on Jul 6, 2016 as substantially equivalent to K102442 (Ld Technology, LLC, 2010) after a 92-day review. Its family tree reaches back 6 generations to 1997. 2 later devices descend from it.

Decided
Jul 6, 2016
Review
92 days
Class
Class II
Product code
MWI
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K963725 (1997). 12 ancestors in all, the oldest K853124 (1985). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2008: 1 other ancestor2003: 1 other ancestor2007: 1 other ancestor1985: 1 other ancestor2005: 1 other ancestor2000: 1 other ancestor2020: 1 descendant cleared2026: 1 descendant clearedK963725 · Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device (Modified) · Card Guard, Ltd. · 1997K012012 · Ecg Home · H&C Medical Devices Spa · 2002K042814 · Readmyheart · Dailycare Biomedical, Inc. · 2005K050620 · Readmyheart, Model RMH3.0 · Dailycare Biomedical, Inc. · 2005K083229 · E.S Teck ( Electro Sensor Teck) · Ld Technology, LLC · 2009K102442 · E.S.O. (Electro Sensor Oxi) · Ld Technology, LLC · 20101990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 2 other ancestors4 generations back: 2 other ancestors5 generations back: 1 other ancestor6 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant K102442 · E.S.O. (Electro Sensor Oxi) · Ld Technology, LLC · 2010K083229 · E.S Teck ( Electro Sensor Teck) · Ld Technology, LLC · 2009K050620 · Readmyheart, Model RMH3.0 · Dailycare Biomedical, Inc. · 2005K042814 · Readmyheart · Dailycare Biomedical, Inc. · 2005K012012 · Ecg Home · H&C Medical Devices Spa · 2002K963725 · Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device (Modified) · Card Guard, Ltd. · 1997−50
  1. Root · 6 generations backK963725 Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device…Card Guard, Ltd. · 1997
  2. 5 generations backK012012 Ecg HomeH&C Medical Devices Spa · 2002
  3. 4 generations backK042814 ReadmyheartDailycare Biomedical, Inc. · 2005
  4. 3 generations backK050620 Readmyheart, Model RMH3.0Dailycare Biomedical, Inc. · 2005
  5. 2 generations backK083229 E.S Teck ( Electro Sensor Teck)Ld Technology, LLC · 2009
  6. 1 generation backK102442 E.S.O. (Electro Sensor Oxi)Ld Technology, LLC · 2010
  7. This deviceK160956 LD-Oxi systemLd Technology, LLC · 2016
  8. Descendant · cites it directly · 1 of its ownK200141 Oxi-W SystemLd Technology, LLC · 2020
  9. Descendant · 2 generations on · 0 of its ownK253306 BioTracker 2.0Biotracker, LLC · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K200141Oxi-W SystemLd Technology, LLC · 2020 · cites it directly1descendant
  • K253306BioTracker 2.0Biotracker, LLC · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K963725Model CG-2206 Personal Electrocardiogram (Ecg) Transmitter Device (Modified)Card Guard, Ltd.1997—
−5K012012Ecg HomeH&C Medical Devices Spa2002—
−4K042814ReadmyheartDailycare Biomedical, Inc.2005—
−3K050620Readmyheart, Model RMH3.0Dailycare Biomedical, Inc.2005—
−2K083229E.S Teck ( Electro Sensor Teck)Ld Technology, LLC2009—
−1K102442E.S.O. (Electro Sensor Oxi)Ld Technology, LLC2010—
0 (this device)K160956LD-Oxi systemLd Technology, LLC2016—
+1K200141Oxi-W SystemLd Technology, LLC2020—
+2K253306BioTracker 2.0Biotracker, LLC2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
200010
200310
200510
200710
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202610
FIG. 1 — Lineage of K160956, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102442E.S.O. (Electro Sensor Oxi)
Summary page 4
…duct Codes: MWI and DQA. Classification: Class II Classification Panel: Cardiovascular /Anesthesiology 3. Predicate legally marketed device Electro Sensor Oxi (ESO) K102442 Applicant: LD Technology LLC Product codes: MWI and DQA 4. Device Description The LD-Oxi System is a programmable electro med…
Ld Technology, LLC2010—

Also cleared against K102442: 1 other device →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K200141Oxi-W SystemLd Technology, LLC20201

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 3.6 years on median.
  • None of the 12 ancestors has a recall.
  • Of its descendants, K200141 (Ld Technology, LLC, 2020) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K102442.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

LD-Oxi system is intended for use: To spot check or monitor Oxygen saturation of arterial hemoglobin (SpO2%) and pulse rate. To analyze the pulse waveform (Photoelectrical Plethysmography or PP) provided by the oximeter. It only provides mathematical analyses of the input of the SpO2 measurement. To analyze the basic rhythms of the NN or RR intervals in heart rate, both in the time domain and in the frequency domain (short time 5 minutes). It only…

Read the full statement (211 words)

LD-Oxi system is intended for use:

To spot check or monitor Oxygen saturation of arterial hemoglobin (SpO2%) and pulse rate.

To analyze the pulse waveform (Photoelectrical Plethysmography or PP) provided by the oximeter. It only provides mathematical analyses of the input of the SpO2 measurement.

To analyze the basic rhythms of the NN or RR intervals in heart rate, both in the time domain and in the frequency domain (short time 5 minutes). It only provides mathematical analysis of the input of the heart rate variability.

The mathematical analysis of Photoelectrical Plethysmography and HRV ARE NOT intended use for diagnosis.

The software provides a visual alarm for the values of the heart rate and/or SpO2 percent out of the normal range and for the bad quality signal transmission.

The data are stored in PC in the Backup system of the LD-Oxi software. The device is intended use only for adult subjects (> 20 years old) This Oximeter is intended to be used in spot-checking (5 minutes).

The device is intended use in licensed practitioner’s office

This device is no intended to be used at home, in hospital or out-of-hospital transport

The device is not intended use in support life and not for continuously monitoring

The system will be use by practitioner.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K160956: LD-Oxi system.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K160956

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026