510(k) Report

510(k) · Cleared

Cleared

OptoMonitor II

K161263510(k) TraditionalCleared Sep 13, 2016131-day reviewClass II21 CFR 870.2870

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Opsens, Inc. · DXO Transducer, Pressure, Catheter Tip

Cleared on Sep 13, 2016 as substantially equivalent to K142598 (Opsens, Inc., 2015) and 2 other predicates after a 131-day review. Its family tree reaches back 7 generations to 1982.

Decided
Sep 13, 2016
Review
131 days
Class
Class II
Product code
DXO
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K823434 (1982). 18 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK823434 Mikro-Tip Catheter Pressure TransducerMillar Instruments, Inc. · 1982
  2. 6 generations backK965140 Cardiometrics Wavewire/Wavemap Pressure SystemCardio Metrics, Inc. · 1997
  3. 5 generations backK021219 Smartwire/Smartmap Pressure SystemJomed, Inc. · 2002
  4. 4 generations backK070487 Smartwire Pressure Guide Wire, Model 66XXVolcano Corporation · 2007
  5. 3 generations backK100930 Primewire Prestiage Pressure Guide Wire, Models 8185, 8185J, 8300…Volcano Corporation · 2010
  6. 2 generations backK111395 Primewire Prestige PlusVolcano Corporation · 2011 · Recalled
  7. 1 generation backK142598 Opto Wire and OptoMonitor SystemOpsens, Inc. · 2015
  8. This deviceK161263 OptoMonitor IIOpsens, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K823434Mikro-Tip Catheter Pressure TransducerMillar Instruments, Inc.1982—
−6K965140Cardiometrics Wavewire/Wavemap Pressure SystemCardio Metrics, Inc.1997—
−5K021219Smartwire/Smartmap Pressure SystemJomed, Inc.2002—
−4K070487Smartwire Pressure Guide Wire, Model 66XXVolcano Corporation2007—
−3K100930Primewire Prestiage Pressure Guide Wire, Models 8185, 8185J, 8300, 8300JVolcano Corporation2010—
−2K111395Primewire Prestige PlusVolcano Corporation20111
−1K142598Opto Wire and OptoMonitor SystemOpsens, Inc.2015—
0 (this device)K161263OptoMonitor IIOpsens, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199110
199220
199310
199420
199510
199620
200410
FIG. 1 — Lineage of K161263, 1982–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXO device

  1. #1 K241418 OptoMonitor 3score 14.8 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K142598Opto Wire and OptoMonitor System
Summary page 4
…cation name: transducer, pressure, catheter tip (870.2870) Regulatory Class: II Product Code: DXO 7.3 PREDICATE DEVICE OptoMonitor System cleared via K142598 (cleared on 06/12/2015). This predicate has not been subject to a design-related recall. No reference devices were used in this s…
Opsens, Inc.2015—
*K111395Primewire Prestige Plus
Summary page 7
…Pending K142598 Predicates K142598 K111395 K041134…
Volcano Corporation20111
*K041134Combomap Pressure and Flow System
Summary page 7
…K142598 K111395 K041134 Product Code DXO DQX, DXO…
Volcano Therapeutics, Inc.2004—

Also cleared against K142598: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 5 companies; a new generation was cleared every 3.9 years on median.
  • 1 of the 18 ancestors has a recall of any class.
  • 3 other devices also cite its predicate K142598.

How does its category compare?

All DXO devices

DXO Transducer, Pressure, Catheter Tip: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DXO

1in 2025

2007: 12008: 12010: 12011: 12012: 12013: 12014: 32015: 22016: 22017: 22018: 12019: 42020: 22022: 12024: 12025: 12026 (partial year): 1
2007high 4 (2019) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXO

120in 2019

2014: 176 days median2019: 120 days median
2007high 176 (2014) · low 120 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXO

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXO

183in 2025

2007: 32008: 22009: 82010: 742011: 1112012: 822013: 932014: 852015: 1142016: 1522017: 1862018: 1792019: 1532020: 1582021: 1162022: 1442023: 1942024: 1972025: 183
2007high 197 (2024) · low 2 (2008)2025

MAUDE reports naming product code DXO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—03
20081—02
20090—08
20101—074
20111—0111
20121—082
20131—093
20143176085
20152—1114
20162—0152
20172—0186
20181—0179
201941200153
20202—0158
20210—0116
20221—0144
20230—0194
20241—0197
20251—0183
20261—0—

What is it indicated for?

The OptoMonitor 2 is a system intended for use in all blood vessels, including coronary and peripheral vasculature, to measure intravascular pressure during angiography and/or interventional procedures.

Pressure measurements are obtained to provide hemodynamic information, such as FFR, for the diagnosis and treatment of blood vessel diseases. Pressure measurements are also obtained to provide intra-catheter or intravascular pressure, such as within occlusion perfusion catheter, for the diagnosis and treatment within the vasculature.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K161263: OptoMonitor II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K161263

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026