510(k) · Cleared
ClearedPC ECG
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Edan Instruments, Inc. · DPS Electrocardiograph
Cleared on Jul 1, 2016 as substantially equivalent to K152427 (Edan Instruments, Inc., 2016) after a 53-day review. Its family tree reaches back 9 generations to 1991. 1 later device descends from it.
- Decided
- Jul 1, 2016
- Review
- 53 days
- Class
- Class II
- Product code
- DPS
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 9 generations to K903644 (1991). 15 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 9 generations backK903644 Series 1500 12-Lead Analysis OptionMarquette Electronics, Inc. · 1991
- 5 generations between
- 3 generations backK102854 PC ECGEdan Instruments, Inc. · 2010
- 2 generations backK131819 PC ECGEdan Instruments, Inc. · 2013
- 1 generation backK152427 PC ECGEdan Instruments, Inc. · 2016
- This deviceK161302 PC ECGEdan Instruments, Inc. · 2016
- Descendant · cites it directly · 0 of its ownK191692 KardioScreenImedrix Inc. (Formerly Piitech Inc.) · 2020
Show all 9 generations
- Root · 9 generations backK903644 Series 1500 12-Lead Analysis OptionMarquette Electronics, Inc. · 1991
- 8 generations backK973403 Cardiosmart STMarquette Medical Systems, Inc. · 1998
- 7 generations backK991014 Case 8000 Exercise Testing SystemGeneral Electric Medical Systems Information Techn · 1999
- 6 generations backK023380 T-Wave Altermans (Twa) Algorithm OptionGeneral Electric Medical Systems Information Techn · 2002
- 5 generations backK031561 Cardiosoft/Case Cardiac Testing SystemGe Medical Systems Information Technologies · 2003
- 4 generations backK092010 PC Ecg, Model SE-1010Edan Instruments, Inc. · 2009
- 3 generations backK102854 PC ECGEdan Instruments, Inc. · 2010
- 2 generations backK131819 PC ECGEdan Instruments, Inc. · 2013
- 1 generation backK152427 PC ECGEdan Instruments, Inc. · 2016
- This deviceK161302 PC ECGEdan Instruments, Inc. · 2016
Most influential descendants
Showing 1 of 1 · See all- K191692KardioScreenImedrix Inc. (Formerly Piitech Inc.) · 2020 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K903644 | Series 1500 12-Lead Analysis Option | Marquette Electronics, Inc. | 1991 | — |
| −8 | K973403 | Cardiosmart ST | Marquette Medical Systems, Inc. | 1998 | — |
| −7 | K991014 | Case 8000 Exercise Testing System | General Electric Medical Systems Information Techn | 1999 | — |
| −6 | K023380 | T-Wave Altermans (Twa) Algorithm Option | General Electric Medical Systems Information Techn | 2002 | — |
| −5 | K031561 | Cardiosoft/Case Cardiac Testing System | Ge Medical Systems Information Technologies | 2003 | — |
| −4 | K092010 | PC Ecg, Model SE-1010 | Edan Instruments, Inc. | 2009 | — |
| −3 | K102854 | PC ECG | Edan Instruments, Inc. | 2010 | — |
| −2 | K131819 | PC ECG | Edan Instruments, Inc. | 2013 | — |
| −1 | K152427 | PC ECG | Edan Instruments, Inc. | 2016 | — |
| 0 (this device) | K161302 | PC ECG | Edan Instruments, Inc. | 2016 | — |
| +1 | K191692 | KardioScreen | Imedrix Inc. (Formerly Piitech Inc.) | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1996 | 2 | 0 |
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
| 2006 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DPS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DPS device
- #1 K212112 Cardiologs Holter Platformscore 18.6 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K152427 | PC ECGSummary page 4…Not applicable, the subject device is Class II. Notification Class III Certification and Summary 4. Predicate Device(s): 1) Edan Instruments, Inc., SE-1515, K152427 5. Reason for New Model. Submission 6. Pre-Submission, Not applicable, there is no Pre-Submission. IDE 7. Dev… | 2016 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K191692 | KardioScreen | 2020 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 5 companies; a new generation was cleared every 2.2 years on median.
- None of the 15 ancestors has a recall.
- Of its descendants, K191692 (Imedrix Inc. (Formerly Piitech Inc.), 2020) has gone furthest, with 0 descendants of its own.
- 2 other devices also cite its predicate K152427.
How does its category compare?
All DPS devicesDPS Electrocardiograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · DPS
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DPS
163in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DPS
3in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · DPS
55in 2025
MAUDE reports naming product code DPS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 11 | 87 | 2 | 9 |
| 2008 | 13 | 31 | 0 | 17 |
| 2009 | 14 | 84 | 1 | 14 |
| 2010 | 11 | 104 | 2 | 21 |
| 2011 | 22 | 154 | 1 | 121 |
| 2012 | 12 | 117 | 0 | 56 |
| 2013 | 10 | 134 | 0 | 15 |
| 2014 | 11 | 253 | 0 | 15 |
| 2015 | 8 | 178 | 0 | 30 |
| 2016 | 11 | 229 | 0 | 12 |
| 2017 | 9 | 177 | 0 | 15 |
| 2018 | 14 | 221 | 0 | 19 |
| 2019 | 3 | 178 | 9 | 27 |
| 2020 | 6 | 224 | 2 | 59 |
| 2021 | 5 | 135 | 1 | 24 |
| 2022 | 6 | 244 | 1 | 59 |
| 2023 | 10 | 236 | 3 | 54 |
| 2024 | 8 | 260 | 4 (1) | 64 |
| 2025 | 6 | 163 | 3 | 55 |
| 2026 | 6 | 258 | 4 | — |
What is it indicated for?
The intended use of PADECG is to acquire resting ECG signals from adult and pediatric patients through body surface ECG electrodes. It is only intended to be used in hospitals or healthcare facilities by doctors and trained healthcare professionals. The cardiogram recorded by PADECG can help users to analyze and diagnose heart disease. However, the interpreted ECG with measurements and interpretive statements is offered to clinicians on an advisory basis only. It is mainly used in ECG inpatient department of hospitals or healthcare facilities.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K161302 · printed Nov 4, 2026
Cite this page
510(k) Report. “K161302: PC ECG.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K161302
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026