510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

GEM Premier 3000

K161818510(k) SpecialCleared Sep 14, 201675-day reviewClass II21 CFR 862.1345Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Instrumentation Laboratory CO · CGA Glucose Oxidase, Glucose

Cleared on Sep 14, 2016 as substantially equivalent to K052121 (Instrumentation Laboratory CO, 2005) after a 75-day review. Its family tree reaches back 5 generations to 1980. It has been recalled 3 times.

Decided
Sep 14, 2016
Review
75 days
Class
Class II
Product code
CGA
Recalls
3
Predicates
1

Its longest line of descent runs back 5 generations to K801848 (1980). 10 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK801848 ICA1 Ionized Calcium AnalyzerThe London Co. · 1980
  2. 4 generations backK963800 IL SynthesisInstrumentation Laboratory CO · 1996
  3. 3 generations backK992834 Gem Premier 3000Instrumentation Laboratory CO · 1999 · Recalled
  4. 2 generations backK022158 Iqm (Intelligent Quality Management) on the Gem Premier 3000, CVP…Instrumentation Laboratory CO · 2002
  5. 1 generation backK052121 Gem Premier 3000Instrumentation Laboratory CO · 2005 · Recalled
  6. This deviceK161818 GEM Premier 3000Instrumentation Laboratory CO · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K801848ICA1 Ionized Calcium AnalyzerThe London Co.1980—
−4K963800IL SynthesisInstrumentation Laboratory CO1996—
−3K992834Gem Premier 3000Instrumentation Laboratory CO19995
−2K022158Iqm (Intelligent Quality Management) on the Gem Premier 3000, CVP (Calibration…Instrumentation Laboratory CO2002—
−1K052121Gem Premier 3000Instrumentation Laboratory CO20052
0 (this device)K161818GEM Premier 3000Instrumentation Laboratory CO2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199410
199510
199610
200110
FIG. 1 — Lineage of K161818, 1980–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CGA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CGA device

  1. #1 K252488 ABL90 FLEX PLUS Systemscore 12.8 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052121Gem Premier 3000
Summary page 4
…September 12, 2016 Device Trade Names GEM Premier 3000 Predicate Device GEM Premier 3000 K052121 Regulatory Information Regulation…
Instrumentation Laboratory CO20052

Also cleared against K052121: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 29, 2023Class IIZ-0357-2024Under Investigation by firmInternal testing identified that the GEM Premier PAKs (cartridges) may exhibit an over-recovery (i.e., positive bias) of pO2 results in the low range (at pO2 levels less than 60 mmHg) that are outside of labeled performance specifications…
Sep 29, 2023Class IIZ-0358-2024Under Investigation by firmInternal testing identified that the GEM Premier PAKs (cartridges) may exhibit an over-recovery (i.e., positive bias) of pO2 results in the low range (at pO2 levels less than 60 mmHg) that are outside of labeled performance specifications…
Sep 29, 2023Class IIZ-0359-2024Under Investigation by firmInternal testing identified that the GEM Premier PAKs (cartridges) may exhibit an over-recovery (i.e., positive bias) of pO2 results in the low range (at pO2 levels less than 60 mmHg) that are outside of labeled performance specifications…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 36 years and passes through 2 companies; a new generation was cleared every 3.1 years on median.
  • 2 of the 10 ancestors have a recall of any class.
  • 1 other device also cites its predicate K052121.

How does its category compare?

All CGA devices

CGA Glucose Oxidase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · CGA

2in 2024

2007: 72008: 62009: 102010: 82011: 92012: 102013: 32014: 52015: 42016: 42017: 22018: 22019: 22020: 22021: 12022: 12023: 42024: 22026 (partial year): 1
2007high 10 (2009) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CGA

249in 2023

2007: 122 days median2008: 56 days median2009: 155 days median2010: 122 days median2011: 217 days median2012: 123 days median2013: 441 days median2014: 265 days median2015: 150 days median2016: 157 days median2023: 249 days median
2007high 441 (2013) · low 56 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CGA

3in 2023

2007: 22008: 22009: 42010: 62011: 32013: 32014: 22015: 6, 2 Class I2016: 22019: 12023: 3
2007high 6 (2010) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · CGA

59in 2025

2007: 292008: 372009: 752010: 1722011: 4232012: 2332013: 1722014: 1222015: 1552016: 362017: 922018: 692019: 1162020: 682021: 482022: 2722023: 1,1412024: 2662025: 59
2007high 1,141 (2023) · low 29 (2007)2025

MAUDE reports naming product code CGA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077122229
2008656237
200910155475
201081226172
201192173423
2012101230233
201334413172
201452652122
201541506 (2)155
20164157236
20172—092
20182—069
20192—1116
20202—068
20211—048
20221—0272
2023424931,141
20242—0266
20250—059
20261—0—

What is it indicated for?

The GEM Premier 3000 is a portable system for use by health care professionals to rapidly analyze whole blood samples at the point of health care delivery in a clinical setting. The instrument provides quantitative measurements of whole blood pH, pCO2, pO2, Na+, K+, Ca++, Glucose, Lactate and Hct. These parameters along with derived parameters aid in the diagnosis of a patient's acid/base status, oxygen delivery capacity, and electrolyte and metabolite balance.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161818: GEM Premier 3000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K161818

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026