Better Water, LLC · FIP Subsystem, Water Purification

Cleared on Dec 13, 2016 as substantially equivalent to K920186 (Better Water, Inc., 1995) and 2 other predicates after a 161-day review. Its family tree reaches back 3 generations to 1995.

Decided
Dec 13, 2016
Review
161 days
Class
Class II
Product code
FIP
Recalls
None
Predicates
3

Its longest line of descent runs back 3 generations to K944385 (1995). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK944385 MD400 a/B/C/D/E/F/GInternational Purification Systems, Inc. · 1995
  2. 2 generations backK993200 MD 420/440/460/470/480/490Isopure, Corp. · 2000
  3. 1 generation backK051620 Matrix Digital Reverse Osmosis Water Treatment System, Model Eqrmd…Better Water, Inc. · 2005
  4. This deviceK161844 Matrix Pre-Treatment ControllerBetter Water, LLC · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K944385MD400 a/B/C/D/E/F/GInternational Purification Systems, Inc.1995—
−2K993200MD 420/440/460/470/480/490Isopure, Corp.2000—
−1K051620Matrix Digital Reverse Osmosis Water Treatment System, Model Eqrmd SeriesBetter Water, Inc.2005—
0 (this device)K161844Matrix Pre-Treatment ControllerBetter Water, LLC2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
200410
FIG. 1 — Lineage of K161844, 1995–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FIP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FIP device

  1. #1 K251851 DIASAFEplusUS (F00013010)score 14.0 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K920186Water Purification System for Hemodialysis
Summary page 5
…Predicate Device#1 Predicate Device#2 Predicate Device#3 Controller 510(k) Number - K920186 K051620 K041163…
Better Water, Inc.1995—
*K051620Matrix Digital Reverse Osmosis Water Treatment System, Model Eqrmd Series
Summary page 5
…Predicate Device#2 Predicate Device#3 Controller 510(k) Number - K920186 K051620 K041163 Matrix Digital Reverse…
Better Water, Inc.2005—
*K041163Isopure Complete Water System for Hemodialysis, MD 400 and MD 600 Series
Summary page 5
…Predicate Device#3 Controller 510(k) Number - K920186 K051620 K041163 Matrix Digital Reverse…
Isopure, Corp.20041

Also cleared against K920186: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 4 companies; a new generation was cleared every 5.8 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 8 other devices also cite its predicate K920186.

How does its category compare?

All FIP devices

FIP Subsystem, Water Purification: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · FIP

4in 2025

2007: 12008: 32009: 32010: 22011: 42012: 22013: 42014: 42015: 22016: 22017: 12018: 12019: 22020: 12021: 12022: 12023: 32024: 12025: 4
2007high 4 (2011) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FIP

88in 2025

2008: 202 days median2009: 167 days median2011: 116 days median2013: 125 days median2014: 126 days median2023: 69 days median2025: 88 days median
2007high 202 (2008) · low 69 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FIP

1in 2020

2020: 1
2007high 1 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FIP

77in 2025

2007: 12008: 52010: 122011: 42012: 42013: 412014: 342015: 122016: 32017: 62018: 32019: 132020: 122021: 352022: 572023: 1402024: 1742025: 77
2007high 174 (2024) · low 0 (2009)2025

MAUDE reports naming product code FIP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
2008320205
2009316700
20102—012
2011411604
20122—04
20134125041
20144126034
20152—012
20162—03
20171—06
20181—03
20192—013
20201—112
20211—035
20221—057
20233690140
20241—0174
2025488077
20260—0—

What is it indicated for?

Matrix Pre-Treatment Controller is designed to safely and effectively provide monitoring and control of the pre-treatment components for water purification for dialysis applications. These pre-treatment components include media-tanks with controllable valves (for example, but not limited to: multi-media depth filters, filox media filters, water softeners, dealkalizers, organic scavengers, and carbon media filters), city booster pump, ultra-violet light…

Read the full statement (191 words)

Matrix Pre-Treatment Controller is designed to safely and effectively provide monitoring and control of the pre-treatment components for water purification for dialysis applications.

These pre-treatment components include media-tanks with controllable valves (for example, but not limited to: multi-media depth filters, filox media filters, water softeners, dealkalizers, organic scavengers, and carbon media filters), city booster pump, ultra-violet light dump valve, blend-valve by-pass valve, and the main water shut-off valve.

It monitors water pressures, water temperature, Delta-P pressures (change in pressure between two points), water flow-rate, water pH, empty bed contact time for carbon media filters, and the status of the media-tanks' valve cycles. This operational data is displayed on a HMI-touch screen along with trends, alarms, and events.

It controls the regeneration and backwash cycles for media tanks, the city booster pump, the ultra-violet light dump valve for cooling purposes, the blend-valve by-pass valve to allow greater flow during backwash and regeneration, and the main water shut-off valve if a leak is detected.

Although it is designed to work with Better Water LLC equipment, it can be used with non-Better Water equipment provided certain components are added or replaced to ensure compatibility.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K161844: Matrix Pre-Treatment Controller.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K161844

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026