510(k) · Cleared
Recalled · Class II · 2018Medtronic Temporary External Pacemaker 53401
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medtronic, Inc. · DTE Pulse-Generator, Pacemaker, External
Cleared on Oct 18, 2016 as substantially equivalent to K132924 (Medtronic, Inc., 2013) after an 85-day review. Its family tree reaches back 1 generation to 2013. 1 later device descends from it. It has been recalled once.
- Decided
- Oct 18, 2016
- Review
- 85 days
- Class
- Class II
- Product code
- DTE
- Recalls
- 1
- Predicates
- 1
Its longest line of descent runs back 1 generation to K132924 (2013). 1 later device descends from it, 1 citing it directly.
- Root · 1 generation backK132924 Medtronic External Pulse Generator (Epg)Medtronic, Inc. · 2013 · Recalled
- This deviceK162054 Medtronic Temporary External Pacemaker 53401Medtronic, Inc. · 2016
- Descendant · cites it directly · 0 of its ownK180873 Medtronic Model 53401 External Pulse Generator (EPG)Medtronic, Inc. · 2018
Most influential descendants
Showing 1 of 1 · See all- K180873Medtronic Model 53401 External Pulse Generator (EPG)Medtronic, Inc. · 2018 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K132924 | Medtronic External Pulse Generator (Epg) | Medtronic, Inc. | 2013 | 1 |
| 0 (this device) | K162054 | Medtronic Temporary External Pacemaker 53401 | Medtronic, Inc. | 2016 | — |
| +1 | K180873 | Medtronic Model 53401 External Pulse Generator (EPG) | Medtronic, Inc. | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2018 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DTE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DTE device
- #1 K232721 Lifetech Cardio Temporary Pacemakerscore 7.2 · 3 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K132924 | Medtronic External Pulse Generator (Epg)Summary page 4…the following predicate device: Medtronic Model 5392 Dual Chamber Temporary External Pacemaker, initially cleared via 510(k) application, reference number K132924 on October 31, 2013. Brief Device Description The Medtronic Temporary External Pacemaker Model 53401 (hereafter simply referred… | 2013 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K180873 | Medtronic Model 53401 External Pulse Generator (EPG) | 2018 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 6, 2018 | Class II | Z-2317-2018 | Device Design | A subset of Medtronic Model 53401 Single Chamber External Pulse Generators (EPGs) may revert from programmed settings to nominal settings during use with a patient due to an unexpected Power on Reset (POR). |
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All DTE devicesDTE Pulse-Generator, Pacemaker, External: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · DTE
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DTE
Too few DTE 510(k)s in any year since 2007 to give a median.
Recalls per year · DTE
2in 2010
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DTE
636in 2025
MAUDE reports naming product code DTE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 17 |
| 2008 | 0 | — | 0 | 22 |
| 2009 | 0 | — | 0 | 39 |
| 2010 | 0 | — | 2 | 335 |
| 2011 | 0 | — | 0 | 1,865 |
| 2012 | 0 | — | 0 | 1,786 |
| 2013 | 2 | — | 0 | 98 |
| 2014 | 0 | — | 0 | 67 |
| 2015 | 1 | — | 0 | 342 |
| 2016 | 2 | — | 0 | 496 |
| 2017 | 0 | — | 0 | 654 |
| 2018 | 2 | — | 0 | 956 |
| 2019 | 2 | — | 0 | 1,001 |
| 2020 | 1 | — | 0 | 1,092 |
| 2021 | 0 | — | 0 | 899 |
| 2022 | 0 | — | 0 | 833 |
| 2023 | 0 | — | 0 | 650 |
| 2024 | 1 | — | 0 | 620 |
| 2025 | 1 | — | 0 | 636 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Model 53401 SC EPG is intended to be used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in a clinical environment. The device can be used where short-term demand (synchronous) or asynchronous pacing is indicated for therapeutic, prophylatic, or diagnostic purposes. Specification indications for temporary cardiac pacing include, but are not limited to, the following indications: • Complete heart block •…
Read the full statement (143 words)
The Model 53401 SC EPG is intended to be used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in a clinical environment. The device can be used where short-term demand (synchronous) or asynchronous pacing is indicated for therapeutic, prophylatic, or diagnostic purposes.
Specification indications for temporary cardiac pacing include, but are not limited to, the following indications:
• Complete heart block
• Sinus bradycardia
• Sick Sinus Syndrome
• Bradycardia with congestive heart failure
• Atrial and/or ventricular arrhythmias
• Cardiac arrest
• Temporary support, management, and evaluation of a patient prior to permanent pacemaker implantation
• Support during permanent pacemaker replacement
• Cardiac complications during invasive or surgical procedures
• Temporary support of a patient following cardiac surgery
• Acute myocardial infarction complicated by heart block
• High-rate burst pacing for the treatment of supraventricular tachyarrhythmias.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K162054 · printed Nov 6, 2026
Cite this page
510(k) Report. “K162054: Medtronic Temporary External Pacemaker 53401.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162054
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026