510(k) Report

510(k) · Cleared

Cleared

Möller Medical Biopsy Needles and Systems

K162588510(k) TraditionalCleared Jun 19, 2017276-day reviewClass II21 CFR 876.1075

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Moller Medical GmbH · KNW Instrument, Biopsy

Cleared on Jun 19, 2017 as substantially equivalent to K980226 (Medical Device Technologies, Inc., 1998) and 8 other predicates after a 276-day review. Its family tree reaches back 3 generations to 1989. 1 of the 35 devices in its family, counting itself, has a Class I recall. 1 later device descends from it.

Decided
Jun 19, 2017
Review
276 days
Class
Class II
Product code
KNW
Recalls
None
Predicates
10

Its longest line of descent runs back 3 generations to K890925 (1989). 33 ancestors in all, the oldest K851831 (1985). 1 later device descends from it, 1 citing it directly. 1 of the 35 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2014: 1 other ancestor2011: 1 other ancestor2001: 2 other ancestors1998: 4 other ancestors1996: 2 other ancestors2009: 1 other ancestor2000: 1 other ancestor1997: 1 other ancestor1994: 4 other ancestors1992: 2 other ancestors1990: 1 other ancestor1989: 2 other ancestors1988: 1 other ancestor1987: 1 other ancestor1985: 6 other ancestors2025: 1 descendant clearedK890925 · Manan Bone Marrow Biopsy Needle · Manan Medical Products, Inc. · 1989 · recalledK961959 · MD Tech Biopsy Set for Bone and Bone Marrow · Medical Device Technologies, Inc. · 1996K980196 · MD Tech Biopsy Set for Bone and Bone Marrow · Medical Device Technologies, Inc. · 1998 · Class I recall1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 8 other ancestors2 generations back: 20 other ancestors3 generations back: 2 other ancestors 1 generation forward: 1 descendant K980196 · MD Tech Biopsy Set for Bone and Bone Marrow · Medical Device Technologies, Inc. · 1998 · Class I recallK961959 · MD Tech Biopsy Set for Bone and Bone Marrow · Medical Device Technologies, Inc. · 1996K890925 · Manan Bone Marrow Biopsy Needle · Manan Medical Products, Inc. · 1989 · recalled0
  1. Root · 3 generations backK890925 Manan Bone Marrow Biopsy NeedleManan Medical Products, Inc. · 1989 · Recalled
  2. 2 generations backK961959 MD Tech Biopsy Set for Bone and Bone MarrowMedical Device Technologies, Inc. · 1996
  3. 1 generation backK980196 MD Tech Biopsy Set for Bone and Bone MarrowMedical Device Technologies, Inc. · 1998 · Recalled (Class I)
  4. This deviceK162588 Möller Medical Biopsy Needles and SystemsMoller Medical GmbH · 2017
  5. Descendant · cites it directly · 0 of its ownK242128 Forsvall biopsy needle system for prostate biopsy (Forsvall biopsy…Xaga Surgical · 2025

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K242128Forsvall biopsy needle system for prostate biopsy (Forsvall biopsy gun and Forsvall…Xaga Surgical · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K890925Manan Bone Marrow Biopsy NeedleManan Medical Products, Inc.19897
−2K961959MD Tech Biopsy Set for Bone and Bone MarrowMedical Device Technologies, Inc.1996—
−1K980196MD Tech Biopsy Set for Bone and Bone MarrowMedical Device Technologies, Inc.1998Class I
0 (this device)K162588Möller Medical Biopsy Needles and SystemsMoller Medical GmbH2017—
+1K242128Forsvall biopsy needle system for prostate biopsy (Forsvall biopsy gun and…Xaga Surgical2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198560
198710
198810
198920
199010
199220
199440
199620
199710
199840
200010
200120
200910
201110
201410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K162588, 1989–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNW device

  1. #1 K260572 Marrow Marxmanscore 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (10)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K980226Manan Pro-Mag Automatic Biopsy System
Summary page 6
…Class II (RBG-xxxx) Needles, Pro-Mag Ultra Automatic Biopsy Instrument 510(k) No.: K980226 Bone Marrow Biopsy Bone Marrow Aspiration Needles; Bone KNW System Marrow Biopsy Trays…
Medical Device Technologies, Inc.19981
*K980196MD Tech Biopsy Set for Bone and Bone Marrow
Summary page 6
…; Pediatric Bone Marrow Access Needles; (BOY-1080) T-Lok Bone Marrow Needles 510(k) No.: K980196 Fine Needle Biopsy Fine Needle Aspiration (FNA) Biopsy KNW (FNB-xxxx) Needles Chiba; Fran…
Medical Device Technologies, Inc.1998Class I
*K980122Manan Soft Tissue Biopsy Needles
Summary page 6
…Cut; Spinal; Trocar; Turner; Westcott Soft Tissue Biopsy Needles 510(k) No.: K980122 Disposable Needles for Biopsy Gun (DNG) DNG-1010 ACN, SACN, Biopsy Needle; KNW…
Medical Device Technologies, Inc.1998—
*K974446Manan Automatic Cutting Needle
Summary page 6
…K980122 Disposable Needles for Biopsy Gun (DNG) DNG-1010 ACN, SACN, Biopsy Needle; KNW 510(k) No.: K974446 Class II DNG-1020; DNG-1030 Pro-Mag Ultra 2.2 Automatic Biopsy KNW…
Manan Medical Products, Inc.1998—
*K111529Magnum Core Tissue Biopsy Needle Model MN1820, RP Cutting Needle Model RP-1820, MCN Core…
Summary page 6
…Class II RP-1820, MCN Core Tissue Biopsy Needle Model MCN 510(k) No.: K111529 2017-05…
Insert Molding Solutions, Inc.2011—
Kept off the family treeK090487FDA’s K090487 is Disposable Angiographic Syringes for Use with Nemoto Angiographic Power, Model…
Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree
Coeur, Inc.2009—
*K010735Speedybell
Summary page 7
….: K904987 Class II Semi-automatic Biopsy Speedybell KNW Gun 510(k) No.: K010735 Class II (SBG-xxxx) Automatic Biopsy Gun Manual-Bone-Marrow-Biopsy-Needles, KNW (AB…
Biopsybell S.A.S.2001—
*K130616Manual-Bone-Marrow-Biopsy-Needles, Semi-Automatic-Biopsy-Needles, Automatic-Biopsy-Needles
Summary page 7
…Semi-Automatic-Biopsy-Needles, Class II ……… Automatic-Biopsy Needles 510(k) No.: K130616 Coaxial Needles Co-Axial Introducer Needle KNW (COX-xxxx) 510(k) No.: K980…
Biopsybell S.R.L.20142
*K980004Manan General Purpose Introducer Needle
Summary page 7
…510(k) No.: K130616 Coaxial Needles Co-Axial Introducer Needle KNW (COX-xxxx) 510(k) No.: K980004 Class II Manual Cut Biopsy 18 Gauge Tru-Cut Biopsy Needle KNW (MBY-xxxx)…
Medical Device Technologies, Inc.1998—
*K96050918 Gauge Tru-Cut Biopsy Needle
Summary page 7
….: K980004 Class II Manual Cut Biopsy 18 Gauge Tru-Cut Biopsy Needle KNW (MBY-xxxx) 510(k) No.: K960509 Class II 4. The presented Möller Medical products have the same indication and the same technology…
Baxter Healthcare Corp1996—

Also cleared against K980226: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K242128Forsvall biopsy needle system for prostate biopsy (Forsvall biopsy gun and Forsvall…Xaga Surgical20250

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K980196MD Tech Biopsy Set for Bone and Bone MarrowMedical Device Technologies, Inc. · 1998 · Direct predicate · ◆ on the line of descent in FIG. 13 Class I recalls

What does this lineage say?

  • The line of descent spans 28 years and passes through 3 companies; a new generation was cleared every 7.3 years on median.
  • 5 of the 33 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K242128 (Xaga Surgical, 2025) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K980226.

How does its category compare?

All KNW devices

KNW Instrument, Biopsy: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · KNW

12in 2025

2007: 62008: 42009: 62010: 32011: 102012: 72013: 32014: 82015: 102016: 92017: 82018: 72019: 52020: 82021: 92022: 82023: 72024: 52025: 122026 (partial year): 7
2007high 12 (2025) · low 3 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNW

178in 2025

2007: 94 days median2008: 53 days median2009: 35 days median2010: 57 days median2011: 64 days median2012: 94 days median2013: 100 days median2014: 95 days median2015: 106 days median2016: 127 days median2017: 90 days median2018: 71 days median2019: 94 days median2020: 92 days median2021: 54 days median2022: 203 days median2023: 164 days median2024: 114 days median2025: 178 days median2026 (partial year): 29 days median
2007high 203 (2022) · low 35 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNW

1in 2024

2007: 12008: 72009: 32010: 22011: 52012: 12013: 1, 1 Class I2014: 32016: 52017: 12019: 42021: 32022: 32023: 22024: 12026 (partial year): 4, 3 Class I
2007high 7 (2008) · low 0 (2015)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · KNW

1,667in 2025

2007: 7662008: 3632009: 3512010: 1622011: 672012: 932013: 982014: 1932015: 5912016: 2972017: 7602018: 1,0122019: 4,1952020: 5,1202021: 1,0202022: 5352023: 9312024: 1,2832025: 1,667
2007high 5,120 (2020) · low 67 (2011)2025

MAUDE reports naming product code KNW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076941766
20084537363
20096353351
20103572162
20111064567
2012794193
201331001 (1)98
20148953193
2015101060591
201691275297
20178901760
201877101,012
201959444,195
202089205,120
202195431,020
202282033535
202371642931
2024511411,283
20251217801,667
20267294 (3)—

What is it indicated for?

The Moller Medical Biopsy Needles and Systems are used to obtain core samples and aspiration from tissue by biopsy. The various wall thicknesses, diameters, tip geometries and cutting techniques of the different hollow needle types and biopsy systems affect the quality of the biopsy specimen. Model BOW-1060 bone marrow biopsy systems are intended for the atraumatic taking of specimens from and inside bones. Application areas of the products are bone…

Read the full statement (452 words)

The Moller Medical Biopsy Needles and Systems are used to obtain core samples and aspiration from tissue by biopsy. The various wall thicknesses, diameters, tip geometries and cutting techniques of the different hollow needle types and biopsy systems affect the quality of the biopsy specimen.

Model BOW-1060 bone marrow biopsy systems are intended for the atraumatic taking of specimens from and inside bones. Application areas of the products are bone respectively bone marrow.

Model BOW-1070 bone marrow aspiration biopsy set is intended for aspiration in the area of the sternum or iliac crest. Application areas of the products are bone respectively bone marrow.

Model BOY-1080 bone biopsy needle set has been designed for atraumatic bone biopsy. Application areas of the products are bone respectively bone marrow.

Model DNG-10XX single-use biopsy needles are exclusively intended for hollow needle biopsies of soft tissue such as liver, kidney, prostate, breast, thyroid, pancreas, spleen, lung and various soft tissue lesions and are combined with biopsy guns.

Model full-sCore® DNG-2020 disposable biopsy needles are intended only for biopsies on soft tissue and tissue from soft, internal organs such as liver, kidney, breast, lung and various soft tissue lesions , and should be used with the Moéller Medical Blue (RBG-1000-10-1000) biopsy gun.

Model FNB and MBY single-use biopsy needles are exclusively intended for hollow needle biopsies of soft tissue for example from pleura cavity and associated organs, abdominal cavity and associated organs like breast, liver, prostate and kidney.

Model COX is for safe needle guidance and for taking several biopsy specimens, for example from liver, kidney, breast, thyroid, pancreas, spleen, lung and various soft tissue lesions, with only one single puncture.

Model ABG disposable automatic biopsy guns are intended for biopsies of soft tissue such as liver, kidney, prostate, breast, thyroid, pancreas, spleen, lung and various soft tissue lesions.

Model SBG disposable semiautomatic biopsy guns are intended for biopsies of soft tissue such as liver, kidney, prostate, breast, thyroid, pancreas, spleen, lung and various soft tissue lesions.

Model Moller Medical Blue RBG is a reusable, automatic biopsy gun that is intended exclusively for use with DNG-1020 / full-sCore® DNG-2020 disposable needles for core needle biopsies of soft tissue such as liver, kidney, prostate, breast, thyroid, pancreas, spleen, lung and various soft tissue lesions.

When used for breast biopsy, the product is for diagnosis only. The extent of histological abnormality cannot be reliably determined from its mammographic appearance. Therefore, the extent of removal of the imaged evidence of an abnormality does not predict the extent of removal of a histological abnormality; e.g., malignancy. When the sampled abnormality is not histologically benign, it is essential that the tissue margins be examined for completeness of removal of using standard surgical procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K162588: Möller Medical Biopsy Needles and Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162588

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026