510(k) Report

510(k) · Cleared

Cleared

Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set (2000MM) Safety Cushion for Tubing Set Attac

K121248510(k) TraditionalCleared Dec 13, 2013597-day reviewClass II21 CFR 882.5550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Moller Medical GmbH · JXG Shunt, Central Nervous System And Components

Cleared on Dec 13, 2013 as substantially equivalent to K030289 (Integra Lifesciences Corp., 2003) and 2 other predicates after a 597-day review. Its family tree reaches back 3 generations to 1986. 1 later device descends from it.

Decided
Dec 13, 2013
Review
597 days
Class
Class II
Product code
JXG
Recalls
None
Predicates
3

Its longest line of descent runs back 3 generations to K864676 (1986). 10 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 4 other ancestors3 generations back: 1 other ancestor 1 generation forward: 1 descendant K030289 · Hermetic Plus External CSF Drainage Systems, Ins-8301,Ins-8302,Ins-8700, NL850-830N · Integra Lifesciences Corp. · 2003K972994 · External CSF Drainage Management Systems · Integra Neurocare, LLC · 1997K864676 · Heyer-Schulte Hermetic External CSF Drain. System · American V. Mueller · 19860
  1. Root · 3 generations backK864676 Heyer-Schulte Hermetic External CSF Drain. SystemAmerican V. Mueller · 1986
  2. 2 generations backK972994 External CSF Drainage Management SystemsIntegra Neurocare, LLC · 1997
  3. 1 generation backK030289 Hermetic Plus External CSF Drainage Systems…Integra Lifesciences Corp. · 2003
  4. This deviceK121248 Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF…Moller Medical GmbH · 2013
  5. Descendant · cites it directly · 0 of its ownK150898 LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH · 2015

Most influential descendants

Showing 1 of 1 · See all
  • K150898LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH · 2015 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K864676Heyer-Schulte Hermetic External CSF Drain. SystemAmerican V. Mueller1986—
−2K972994External CSF Drainage Management SystemsIntegra Neurocare, LLC1997—
−1K030289Hermetic Plus External CSF Drainage Systems, Ins-8301,Ins-8302,Ins-8700…Integra Lifesciences Corp.2003—
0 (this device)K121248Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set…Moller Medical GmbH2013—
+1K150898LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199120
199520
200310
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201510
FIG. 1 — Lineage of K121248, 1986–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JXG device

  1. #1 K243531 Codman Libertís Shunt Catheter with Bactiseal…score 11.9 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K030289Hermetic Plus External CSF Drainage Systems, Ins-8301,Ins-8302,Ins-8700, NL850-830N
Summary page 2
…quivalent to the 9SF drainage systems listed below with regard to intended use, design, operating principles, and materials. Integra NeuroSciences Corporation K030289, K03281 7 Codman & Shurtleff, Inc. K061568 The Mdller Medical LiquoGuard CSF System shares features with, the…
Integra Lifesciences Corp.2003—
*K032817External Drainage Set
Summary page 2
…to the 9SF drainage systems listed below with regard to intended use, design, operating principles, and materials. Integra NeuroSciences Corporation K030289, K03281 7 Codman & Shurtleff, Inc. K061568 The Mdller Medical LiquoGuard CSF System shares features with, the intracran…
Integra Neurosciences Implants S.A.20031
*K061568Codman Eds 3 CSF External Drainage System, Models 82-1730, 82-1731, 82-1732, 82-1733…
Summary page 2
…to intended use, design, operating principles, and materials. Integra NeuroSciences Corporation K030289, K03281 7 Codman & Shurtleff, Inc. K061568 The Mdller Medical LiquoGuard CSF System shares features with, the intracranial pressure monitor listed below (the shared feature…
Codman & Shurtleff, Inc.20063
†K962928Combined Intracranial Pressure-Temperature Sensing System (Icp/)Camino Neurocare, Inc.19962

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K150898LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 4 companies; a new generation was cleared every 10.8 years on median.
  • 4 of the 10 ancestors have a recall of any class.
  • Of its descendants, K150898 (Moller Medical GmbH, 2015) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JXG devices

JXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · JXG

8in 2025

2007: 32008: 62009: 52010: 32011: 72012: 32013: 32015: 62016: 62017: 72018: 62019: 42020: 22021: 12022: 42023: 52024: 32025: 82026 (partial year): 2
2007high 8 (2025) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JXG

255in 2025

2007: 184 days median2008: 60 days median2009: 106 days median2010: 30 days median2011: 136 days median2012: 78 days median2013: 108 days median2015: 276 days median2016: 143 days median2017: 90 days median2018: 102 days median2019: 101 days median2022: 101 days median2023: 134 days median2024: 90 days median2025: 255 days median
2007high 276 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JXG

3in 2024

2008: 12009: 302011: 52012: 12013: 142014: 62017: 12020: 82023: 22024: 32026 (partial year): 1
2007high 30 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JXG

1,198in 2025

2007: 6492008: 6302009: 6292010: 8122011: 7872012: 9772013: 1,0042014: 1,2512015: 9842016: 1,0912017: 1,3352018: 1,4842019: 1,2952020: 1,2062021: 1,4672022: 1,3292023: 1,2212024: 1,2142025: 1,198
2007high 1,484 (2018) · low 629 (2009)2025

MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731840649
20086601630
2009510630629
20103300812
201171365787
20123781977
20133108141,004
20140—61,251
201562760984
2016614301,091
201779011,335
2018610201,484
2019410101,295
20202—81,206
20211—01,467
2022410101,329
2023513421,221
202439031,214
2025825501,198
20262—1—

What is it indicated for?

The LiquoGuard CSF system is indicated for the external drainage of cerebrospinal fluid (CSF). It connects to any drainage catheter (not part of the product) which is usually inserted by the doctor into the lateral or third ventricle of the brain or lumbar subarachnoid space in selected patients to reduce intracranial pressure. The LiquoGuard CSF system controls CSF pressure using pressure sensors and a pump, thus taking the role of the conventional CSF…

Read the full statement (112 words)

The LiquoGuard CSF system is indicated for the external drainage of cerebrospinal fluid (CSF). It connects to any drainage catheter (not part of the product) which is usually inserted by the doctor into the lateral or third ventricle of the brain or lumbar subarachnoid space in selected patients to reduce intracranial pressure. The LiquoGuard CSF system controls CSF pressure using pressure sensors and a pump, thus taking the role of the conventional CSF dripping chamber and collection bag (predicate devices). The LiquoGuard CSF system also monitors intracranial pressure up to 75 mmHg and cerebrospinal fluid flow during CSF drainage, and provides many alarm functions not offered by the passive dripping chamber systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121248: Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set (2000MM) Safety Cushion for Tubing Set Attac.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121248

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026