Hamilton-H900, Hamilton-BC8010, Hamilton-BC4010

K163283510(k) TraditionalCleared Sep 20, 2017303-day reviewClass II21 CFR 868.5450Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hamilton Medical AG · BTT Humidifier, Respiratory Gas, (Direct Patient Interface)

Cleared on Sep 20, 2017 as substantially equivalent to K152029 (Hamilton Medical AG, 2016) after a 303-day review. Its family tree reaches back 8 generations to 1992. It has been recalled once.

Decided
Sep 20, 2017
Review
303 days
Class
Class II
Product code
BTT
Recalls
1
Predicates
1

Its longest line of descent runs back 8 generations to K913368 (1992). 12 ancestors in all, the oldest K902506 (1991). No later device cites it as a predicate yet.

  1. Root · 8 generations backK913368 Models MR700/MR720/MR730 Dual Servo Resp Humid AccFisher & Paykel Electronics, Ltd. · 1992
  2. 7 generations backK953392 HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd. · 1996
  3. 6 generations backK983112 Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd. · 1998 · Recalled
  4. 5 generations backK020332 Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd. · 2003 · Recalled
  5. 4 generations backK034026 RT 138 & RT 141 Dual-Heated Neonatal Breathing CircuitsFisher & Paykel Healthcare, Ltd. · 2005
  6. 3 generations backK103767 Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd. · 2012
  7. 2 generations backK122432 Adult Evaqua 2' Dual Heated Breathing CircuitsFisher & Paykel Healthcare, Ltd. · 2012
  8. 1 generation backK152029 Hamilton-H900, Hamilton-BC8022, Hamilton-BC4022, Hamilton-BC8010…Hamilton Medical AG · 2016
  9. This deviceK163283 Hamilton-H900, Hamilton-BC8010, Hamilton-BC4010Hamilton Medical AG · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K913368Models MR700/MR720/MR730 Dual Servo Resp Humid AccFisher & Paykel Electronics, Ltd.1992—
−7K953392HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd.1996—
−6K983112Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd.19985
−5K020332Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd.20031
−4K034026RT 138 & RT 141 Dual-Heated Neonatal Breathing CircuitsFisher & Paykel Healthcare, Ltd.2005—
−3K103767Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd.2012—
−2K122432Adult Evaqua 2' Dual Heated Breathing CircuitsFisher & Paykel Healthcare, Ltd.2012—
−1K152029Hamilton-H900, Hamilton-BC8022, Hamilton-BC4022, Hamilton-BC8010…Hamilton Medical AG2016—
0 (this device)K163283Hamilton-H900, Hamilton-BC8010, Hamilton-BC4010Hamilton Medical AG2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199210
199410
200010
FIG. 1 — Lineage of K163283, 1992–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BTT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTT device

  1. #1 K222197 F&P Optiflow Junior 2/2+ Nasal Cannula…score 16.8 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K152029Hamilton-H900, Hamilton-BC8022, Hamilton-BC4022, Hamilton-BC8010, Hamilton-BC4010
Summary page 5
…Page 5 === III. Predicate Device(s) Predicate Device for Humidifier Hamilton Medical AG HAMILTON-H900, respiratory gas humidifier, K152029 Predicate Devices for Heated Breathing Circuits Hamilton Medical AG HAMILTON-BC8010 and HAMILT…
Hamilton Medical AG2016—
†K983112Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd.19985
†K103767Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd.2012—
†K151959AirLife Infant Single Limb Heated Wire CircuitCarefusion, Inc.2016—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 5, 2021Class IIIZ-1385-2022Employee errorWhen starting a humidifier, intended for respiratory gas conditioning during invasive and noninvasive mechanical ventilation, with an empty chamber, and water is not filled into the chamber, the low water level alarm will be delayed and…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 3 companies; a new generation was cleared every 3.4 years on median.
  • 2 of the 12 ancestors have a recall of any class.

How does its category compare?

All BTT devices

BTT Humidifier, Respiratory Gas, (Direct Patient Interface): FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · BTT

4in 2025

2007: 62008: 42009: 12010: 42011: 32012: 22013: 62014: 72015: 12016: 32017: 32018: 22019: 12020: 22021: 22022: 32023: 72024: 72025: 42026 (partial year): 4
2007high 7 (2014) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTT

104in 2025

2007: 73 days median2008: 199 days median2010: 113 days median2011: 116 days median2013: 171 days median2014: 231 days median2016: 157 days median2017: 303 days median2022: 290 days median2023: 258 days median2024: 219 days median2025: 104 days median2026 (partial year): 184 days median
2007high 303 (2017) · low 73 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTT

1in 2025

2007: 12008: 12010: 22011: 12014: 5, 4 Class I2025: 12026 (partial year): 1
2007high 5 (2014) · low 0 (2009)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · BTT

1,743in 2025

2007: 3652008: 4562009: 5582010: 5622011: 6652012: 5832013: 7182014: 7182015: 6702016: 1,0942017: 1,0072018: 9182019: 8942020: 1,1882021: 1,5102022: 7492023: 7162024: 5012025: 1,743
2007high 1,743 (2025) · low 365 (2007)2025

MAUDE reports naming product code BTT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076731365
200841991456
20091—0558
201041132562
201131161665
20122—0583
201361710718
201472315 (4)718
20151—0670
2016315701,094
2017330301,007
20182—0918
20191—0894
20202—01,188
20212—01,510
202232900749
202372580716
202472190501
2025410411,743
202641841—

What is it indicated for?

The HAMILTON-H900 humidifier is intended to add moisture and to warm breathing gases during invasive and non-invasive mechanical ventilation. The intended area of use is the intensive care ward or the recovery room. The HAMILTON-H900 humidifier is a medical device intended for use by qualified, trained personnel under the direction of a physician and within the limits of its stated technical specifications. The HAMILTON-BC8010 breathing set is intended…

Read the full statement (118 words)

The HAMILTON-H900 humidifier is intended to add moisture and to warm breathing gases during invasive and non-invasive mechanical ventilation. The intended area of use is the intensive care ward or the recovery room.

The HAMILTON-H900 humidifier is a medical device intended for use by qualified, trained personnel under the direction of a physician and within the limits of its stated technical specifications.

The HAMILTON-BC8010 breathing set is intended to be used together with compatible Hamilton Medical respiratory gas humidifiers during invasive and noninvasive mechanical ventilation of pediatric and neonatal patients.

The HAMILTON-BC4010 breathing set is intended to be used together with compatible Hamilton Medical respiratory gas humidifiers during invasive and noninvasive mechanical ventilation of pediatric and neonatal patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K163283: Hamilton-H900, Hamilton-BC8010, Hamilton-BC4010.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K163283

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026