510(k) Report

510(k) · Cleared

Cleared

VITROS Chemistry Products GLU Slides

K163433510(k) TraditionalCleared Sep 18, 2017285-day reviewClass II21 CFR 862.1345

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ortho Clinical Diagnostics · CGA Glucose Oxidase, Glucose

Cleared on Sep 18, 2017 as substantially equivalent to K955286 (Johnson & Johnson Clinical Diagnostics, Inc., 1996) after a 285-day review. Its family tree reaches back 1 generation to 1996. 2 later devices descend from it.

Decided
Sep 18, 2017
Review
285 days
Class
Class II
Product code
CGA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K955286 (1996). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2018: 1 descendant cleared2019: 1 descendant clearedK955286 · Ektachem Clinical Chemistry Slide Glucose (Glu) · Johnson & Johnson Clinical Diagnostics, Inc. · 1996 · recalled1995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K955286 · Ektachem Clinical Chemistry Slide Glucose (Glu) · Johnson & Johnson Clinical Diagnostics, Inc. · 1996 · recalled0
  1. Root · 1 generation backK955286 Ektachem Clinical Chemistry Slide Glucose (Glu)Johnson & Johnson Clinical Diagnostics, Inc. · 1996 · Recalled
  2. This deviceK163433 VITROS Chemistry Products GLU SlidesOrtho Clinical Diagnostics · 2017
  3. Descendant · cites it directly · 1 of its ownK182072 VITROS Chemistry Products Cl-Slides, VITROS Chemistry Products ECO2…Ortho-Clinical Diagnostics, Inc. · 2018 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK190520 VITROS XT Chemistry Products GLU-Ca SlidesOrtho-Clinical Diagnostics, Inc. · 2019

Most influential descendants

Showing 2 of 2 · See all
  • K182072VITROS Chemistry Products Cl-Slides, VITROS Chemistry Products ECO2 Slides, VITROS…Ortho-Clinical Diagnostics, Inc. · 2018 · cites it directly1descendant
  • K190520VITROS XT Chemistry Products GLU-Ca SlidesOrtho-Clinical Diagnostics, Inc. · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K955286Ektachem Clinical Chemistry Slide Glucose (Glu)Johnson & Johnson Clinical Diagnostics, Inc.19967
0 (this device)K163433VITROS Chemistry Products GLU SlidesOrtho Clinical Diagnostics2017—
+1K182072VITROS Chemistry Products Cl-Slides, VITROS Chemistry Products ECO2 Slides…Ortho-Clinical Diagnostics, Inc.20182
+2K190520VITROS XT Chemistry Products GLU-Ca SlidesOrtho-Clinical Diagnostics, Inc.2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
FIG. 1 — Lineage of K163433, 1996–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CGA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CGA device

  1. #1 K252488 ABL90 FLEX PLUS Systemscore 12.8 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K955286Ektachem Clinical Chemistry Slide Glucose (Glu)
Summary page 4
…fied) are substantially equivalent to the VITROS® Chemistry Products GLU Slides (current). The FDA cleared the VITROS® Chemistry Products GLU Slides on May 17, 1996 (k955286). Reason for 510(k) submission The device modification is a proportional reduction in the amount of reagent used to manufa…
Johnson & Johnson Clinical Diagnostics, Inc.19967

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K182072VITROS Chemistry Products Cl-Slides, VITROS Chemistry Products ECO2 Slides, VITROS…Ortho-Clinical Diagnostics, Inc.20181

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K182072 (Ortho-Clinical Diagnostics, Inc., 2018) has gone furthest, with 1 descendant of its own.

How does its category compare?

All CGA devices

CGA Glucose Oxidase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · CGA

2in 2024

2007: 72008: 62009: 102010: 82011: 92012: 102013: 32014: 52015: 42016: 42017: 22018: 22019: 22020: 22021: 12022: 12023: 42024: 22026 (partial year): 1
2007high 10 (2009) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CGA

249in 2023

2007: 122 days median2008: 56 days median2009: 155 days median2010: 122 days median2011: 217 days median2012: 123 days median2013: 441 days median2014: 265 days median2015: 150 days median2016: 157 days median2023: 249 days median
2007high 441 (2013) · low 56 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CGA

3in 2023

2007: 22008: 22009: 42010: 62011: 32013: 32014: 22015: 6, 2 Class I2016: 22019: 12023: 3
2007high 6 (2010) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · CGA

59in 2025

2007: 292008: 372009: 752010: 1722011: 4232012: 2332013: 1722014: 1222015: 1552016: 362017: 922018: 692019: 1162020: 682021: 482022: 2722023: 1,1412024: 2662025: 59
2007high 1,141 (2023) · low 29 (2007)2025

MAUDE reports naming product code CGA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077122229
2008656237
200910155475
201081226172
201192173423
2012101230233
201334413172
201452652122
201541506 (2)155
20164157236
20172—092
20182—069
20192—1116
20202—068
20211—048
20221—0272
2023424931,141
20242—0266
20250—059
20261—0—

What is it indicated for?

For in vitro diagnostic use only. VITROS Chemistry Products GLU Slides are used on VITROS Systems to quantitatively measure glucose (GLU) concentration in serum, plasma, urine and cerebrospinal fluid.

Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K163433: VITROS Chemistry Products GLU Slides.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K163433

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026