510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

BD MAX Extended Enteric Bacterial Panel, BD MAX System

K170308510(k) TraditionalCleared May 2, 201790-day reviewClass II21 CFR 866.3990Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton, Dickinson and Company · PCH Gastrointestinal Pathogen Panel Multiplex Nucleic Acid-Based Assay System

Cleared on May 2, 2017 as substantially equivalent to K160459 (Biofire Diagnostics, LLC, 2016) after a 90-day review. Its family tree reaches back 4 generations to 2013. 2 later devices descend from it. It has been recalled once.

Decided
May 2, 2017
Review
90 days
Class
Class II
Product code
PCH
Recalls
1
Predicates
1

Its longest line of descent runs back 4 generations to DEN130003 (2013). 2 later devices descend from it, 2 citing it directly.

  1. Root · 4 generations backDEN130003 Xtag Gastrointestinal Pathogen Panel (GPP) Xtag Data Analysis…Luminex Molecular Diagnostics, Inc. · 2013
  2. 3 generations backK140407 Filmarray Gastrointestinal (GI) PanelBiofire Diagnostics · 2014 · Recalled
  3. 2 generations backK143005 FilmArray Gastrointestinal (GI) Panel for use with the FilmArray 2.0Biofire Diagnostics, LLC · 2015 · Recalled
  4. 1 generation backK160459 FilmArray Gastrointestinal Panel (GI) for use with FilmArray TorchBiofire Diagnostics, LLC · 2016 · Recalled
  5. This deviceK170308 BD MAX Extended Enteric Bacterial Panel, BD MAX SystemBecton, Dickinson and Company · 2017
  6. Descendant · cites it directly · 1 of its ownK214122 BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial…Becton, Dickinson and Company · 2022
  7. Descendant · cites it directly · 0 of its ownK250358 BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial…Becton, Dickinson and Company · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K214122BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial PanelBecton, Dickinson and Company · 2022 · cites it directly1descendant
  • K250358BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial Panel plus for BD COR…Becton, Dickinson and Company · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4DEN130003Xtag Gastrointestinal Pathogen Panel (GPP) Xtag Data Analysis Software for GPP…Luminex Molecular Diagnostics, Inc.2013—
−3K140407Filmarray Gastrointestinal (GI) PanelBiofire Diagnostics20148
−2K143005FilmArray Gastrointestinal (GI) Panel for use with the FilmArray 2.0Biofire Diagnostics, LLC20157
−1K160459FilmArray Gastrointestinal Panel (GI) for use with FilmArray TorchBiofire Diagnostics, LLC20166
0 (this device)K170308BD MAX Extended Enteric Bacterial Panel, BD MAX SystemBecton, Dickinson and Company2017—
+1K214122BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial PanelBecton, Dickinson and Company2022—
+1K250358BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial Panel plus…Becton, Dickinson and Company2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202510
FIG. 1 — Lineage of K170308, 2013–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PCH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PCH device

  1. #1 K220062 QIAstat-Dx Gastrointestinal Panel 2score 16.7 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160459FilmArray Gastrointestinal Panel (GI) for use with FilmArray Torch
Summary page 5
…plex Nucleic Acid-Based Assay System OOI- Real Time Nucleic Acid Amplification System Predicate Device BioFire Diagnostics FilmArray Gastrointestinal (GI) Panel [510(k) K160459] Device Establishment GeneOhm Sciences Canada, Inc. (BD Diagnostics) 2555 Boul. du Parc-Technologique Quebec, QC G1P 4S5 Canada…
Biofire Diagnostics, LLC20166

Also cleared against K160459: 3 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K214122BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial PanelBecton, Dickinson and Company20221
K250358BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial Panel plus for BD COR…Becton, Dickinson and Company20250

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 17, 2019Class IIZ-2338-2019Process controlThe foil bags containing extraction tubes for BD MAX" Reagent products may not been sealed properly.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 4 companies; a new generation was cleared every 1.1 years on median.
  • 3 of the 4 ancestors have a recall of any class.
  • Of its descendants, K214122 (Becton, Dickinson and Company, 2022) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K160459.

How does its category compare?

All PCH devices

PCH Gastrointestinal Pathogen Panel Multiplex Nucleic Acid-Based Assay System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · PCH

7in 2025

2013: 32014: 62015: 22016: 22017: 12018: 42019: 42022: 22023: 12024: 32025: 72026 (partial year): 3
2007high 7 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PCH

89in 2025

2014: 120 days median2018: 105 days median2019: 191 days median2024: 271 days median2025: 89 days median2026 (partial year): 176 days median
2007high 271 (2024) · low 89 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PCH

5in 2025

2023: 12025: 5
2007high 5 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PCH

40in 2025

2014: 12019: 42021: 262022: 472023: 622024: 452025: 40
2007high 62 (2023) · low 0 (2007)2025

MAUDE reports naming product code PCH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20133—00
2014612001
20152—00
20162—00
20171—00
2018410500
2019419104
20200—00
20210—026
20222—047
20231—162
20243271045
2025789540
202631760—

What is it indicated for?

The BD MAX™ Extended Enteric Bacterial Panel performed on the BD MAX System, is an automated in vitro diagnostic test for the direct qualitative detection and differentiation of enteric bacterial pathogens. It is used in conjunction with the BD MAX Enteric Bacterial Panel as an optional Master Mix. The BD MAX™ Extended Enteric Bacterial Panel detects nucleic acids from e Plesiomonas shigelloides e Vibrio (V. vulnificus, V. parahaemolyticus, and V.…

Read the full statement (277 words)

The BD MAX™ Extended Enteric Bacterial Panel performed on the BD MAX System, is an automated in vitro diagnostic test for the direct qualitative detection and differentiation of enteric bacterial pathogens. It is used in conjunction with the BD MAX Enteric Bacterial Panel as an optional Master Mix. The BD MAX™ Extended Enteric Bacterial Panel detects nucleic acids from

e Plesiomonas shigelloides

e Vibrio (V. vulnificus, V. parahaemolyticus, and V. cholerae)

e Enterotoxigenic Escherichia coli (ETEC) heat-labile enterotoxin (LT)/ heat-stable enterotoxin (ST) genes

e Yersinia enterocolitica

Testing is performed on soft to diarrheal unpreserved stool specimens or Cary-Blair preserved stool specimens from symptomatic patients with suspected acute gastroenteritis, enteritis or colitis. The test is performed directly on the specimen, utilizing real-time polymerase chain reaction (PCR) for the amplification of relevant gene target DNA. The test utilizes fluorogenic gene-specific hybridization probes for the detection of the amplified DNA.

This test is intended for use, in conjunction with clinical presentation, laboratory findings, and epidemiological information, as an aid in the differential diagnosis of Plesiomonas shigelloides, Vibrio (V. vulnificus, V. parahaemolyticus, and V. cholerae), Enterotoxigenic Escherichia coli (ETEC) LT/ST and Yersinia enterocolitica infections. Results of this test should not be used as the sole basis for diagnosis, treatment, or other patient management decisions. Positive results do not rule out co-infection with other organisms that are not detected by this test, and may not be the sole or definitive cause of patient illness. Negative results in the setting of clinical illness compatible with gastroenteritis may be due to infection by pathogens that are not detected by this test or non-infectious causes such as ulcerative colitis, irritable bowel syndrome, or Crohn’s disease.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K170308: BD MAX Extended Enteric Bacterial Panel, BD MAX System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K170308

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026