510(k) Report

510(k) · Cleared

Cleared

BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial Panel plus for BD COR System, and Enteric Bacterial Panel Diluent for BD COR System

K250358510(k) TraditionalCleared Oct 31, 2025266-day reviewClass II21 CFR 866.3990

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton, Dickinson and Company · PCI Gastrointestinal Bacterial Panel Multiplex Nucleic Acid-Based Assay System

Cleared on Oct 31, 2025 as substantially equivalent to K140111 (Becton, Dickinson and Company, 2014) and 2 other predicates after a 266-day review. Its family tree reaches back 6 generations to 2013.

Decided
Oct 31, 2025
Review
266 days
Class
Class II
Product code
PCI
Recalls
None
Predicates
3

Its longest line of descent runs back 6 generations to DEN130003 (2013). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backDEN130003 Xtag Gastrointestinal Pathogen Panel (GPP) Xtag Data Analysis…Luminex Molecular Diagnostics, Inc. · 2013
  2. 5 generations backK140407 Filmarray Gastrointestinal (GI) PanelBiofire Diagnostics · 2014 · Recalled
  3. 4 generations backK143005 FilmArray Gastrointestinal (GI) Panel for use with the FilmArray 2.0Biofire Diagnostics, LLC · 2015 · Recalled
  4. 3 generations backK160459 FilmArray Gastrointestinal Panel (GI) for use with FilmArray TorchBiofire Diagnostics, LLC · 2016 · Recalled
  5. 2 generations backK170308 BD MAX Extended Enteric Bacterial Panel, BD MAX SystemBecton, Dickinson and Company · 2017 · Recalled
  6. 1 generation backK214122 BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial…Becton, Dickinson and Company · 2022
  7. This deviceK250358 BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial…Becton, Dickinson and Company · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6DEN130003Xtag Gastrointestinal Pathogen Panel (GPP) Xtag Data Analysis Software for GPP…Luminex Molecular Diagnostics, Inc.2013—
−5K140407Filmarray Gastrointestinal (GI) PanelBiofire Diagnostics20148
−4K143005FilmArray Gastrointestinal (GI) Panel for use with the FilmArray 2.0Biofire Diagnostics, LLC20157
−3K160459FilmArray Gastrointestinal Panel (GI) for use with FilmArray TorchBiofire Diagnostics, LLC20166
−2K170308BD MAX Extended Enteric Bacterial Panel, BD MAX SystemBecton, Dickinson and Company20171
−1K214122BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial PanelBecton, Dickinson and Company2022—
0 (this device)K250358BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial Panel plus…Becton, Dickinson and Company2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201310
201410
FIG. 1 — Lineage of K250358, 2013–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PCI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PCI device

  1. #1 K214122 BD MAX Enteric Bacterial Panel, BD MAX…score 7.9 · 5 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140111BD Max (TM) Enteric Bacterial Panel;BD Max (TM) Instrument
Summary page 12
…Proposed: BD Enteric Bacterial Predicate: BD MAX xEBP Proposed BD Enteric Bacterial Panel plus Item (K140111, K214122) Panel for BD COR™ System (K170308, K214122) for BD COR™…
Becton, Dickinson and Company20142
*K214122BD MAX Enteric Bacterial Panel, BD MAX Extended Enteric Bacterial Panel
Summary page 7
…Detection and Identification of Microorganisms and Toxin Genes from Human Stool Specimens, November 2, 2015. Predicate Device BD MAX™ Enteric Bacterial Panel (K170308, K214122) and BD MAX™ Extended Enteric Bacterial Panel (K170308, K214122) Device Establishment Registration Number: 1119779 Intended Us…
Becton, Dickinson and Company2022—
*K170308BD MAX Extended Enteric Bacterial Panel, BD MAX System
Summary page 7
…says for Detection and Identification of Microorganisms and Toxin Genes from Human Stool Specimens, November 2, 2015. Predicate Device BD MAX™ Enteric Bacterial Panel (K170308, K214122) and BD MAX™ Extended Enteric Bacterial Panel (K170308, K214122) Device Establishment Registration Number: 1119779 In…
Becton, Dickinson and Company20171

Also cleared against K140111: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 4 companies; a new generation was cleared every 1.3 years on median.
  • 5 of the 8 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K140111.

How does its category compare?

All PCI devices

PCI Gastrointestinal Bacterial Panel Multiplex Nucleic Acid-Based Assay System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · PCI

1in 2025

2014: 12017: 12018: 12022: 12025: 1
2007high 1 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PCI

Too few PCI 510(k)s in any year since 2007 to give a median.

Recalls per year · PCI

No recall names PCI since 2007.

Adverse event reports per year · PCI

7in 2025

2020: 12021: 62022: 102023: 262025: 7
2007high 26 (2023) · low 0 (2007)2025

MAUDE reports naming product code PCI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20141—00
20150—00
20160—00
20171—00
20181—00
20190—00
20200—01
20210—06
20221—010
20230—026
20240—00
20251—07
20260—0—

What is it indicated for?

BD Enteric Bacterial Panel for BD COR™ System BD Enteric Bacterial Panel for BD COR™ System is an automated in vitro diagnostic test for the direct qualitative detection and differentiation of enteric bacterial pathogens. BD Enteric Bacterial Panel for BD COR™ System detects nucleic acids from: • Salmonella spp. • Campylobacter spp. (C. jejuni and C. coli) • Shigella spp. / Enteroinvasive Escherichia coli (EIEC) • Shiga toxin 1 (stx1) / Shiga toxin 2…

Read the full statement (728 words)

BD Enteric Bacterial Panel for BD COR™ System

BD Enteric Bacterial Panel for BD COR™ System is an automated in vitro diagnostic test for the direct qualitative detection and differentiation of enteric bacterial pathogens. BD Enteric Bacterial Panel for BD COR™ System detects nucleic acids from:

• Salmonella spp.

• Campylobacter spp. (C. jejuni and C. coli)

• Shigella spp. / Enteroinvasive Escherichia coli (EIEC)

• Shiga toxin 1 (stx1) / Shiga toxin 2 (stx2) genes (found in Shiga toxin-producing Escherichia coli [STEC]) as well as Shigella dysenteriae, which can possess a Shiga toxin gene (stx) that is identical to the stx1 gene of STEC.

Testing is performed utilizing the BD Fecal Collection and Transport Kit. Unpreserved soft to diarrheal stool specimens from symptomatic patients with suspected acute gastroenteritis, enteritis or colitis are probed using the flocked swab and material is transferred to the BD Fecal Collection and Transport tube containing modified Cary-Blair medium. The test is performed utilizing real-time polymerase chain reaction (PCR) for the amplification of specific sequences of target DNA. The test utilizes fluorogenic sequence-specific hybridization probes for detection of the amplified DNA.

This test is intended for use, in conjunction with clinical presentation, laboratory findings, and epidemiological information, as an aid in the differential diagnosis of Salmonella, Shigella/EIEC, Campylobacter, and Shiga toxin-producing E. coli (STEC). Results of this test should not be used as the sole basis for diagnosis, treatment, or other patient management decisions. Positive results do not rule out co-infection with other organisms that are not detected by this test and may not be the sole or definitive cause of patient illness. Negative results in the setting of clinical illness compatible with gastroenteritis may be due to infection by pathogens that are not detected by this test or non-infectious causes such as ulcerative colitis, irritable bowel syndrome, or Crohn’s disease.

BD Enteric Bacterial Panel plus for BD COR™ System

BD Enteric Bacterial Panel plus for BD COR™ System is an automated in vitro diagnostic test for the direct qualitative detection and differentiation of enteric bacterial pathogens. BD Enteric Bacterial Panel plus for BD COR™ System detects nucleic acids from:

• Salmonella spp.

• Campylobacter spp. (C. jejuni and C. coli)

• Shigella spp. / Enteroinvasive Escherichia coli (EIEC)

• Shiga toxin 1 (stx1) / Shiga toxin 2 (stx2) genes (found in Shiga toxin-producing Escherichia coli [STEC]) as well as Shigella dysenteriae, which can possess a Shiga toxin gene (stx) that is identical to the stx1 gene of STEC.

• Plesiomonas shigelloides

• Vibrio spp. (V. vulnificus, V. parahaemolyticus, and V. cholerae)

• Enterotoxigenic Escherichia coli (ETEC) heat-labile enterotoxin (LT) / heat-stable enterotoxin (ST) genes

• Yersinia enterocolitica

Testing is performed utilizing the BD Fecal Collection and Transport Kit. Unpreserved soft to diarrheal stool specimens from symptomatic patients with suspected acute gastroenteritis, enteritis or colitis are probed using the flocked swab and material is transferred to the BD Fecal Collection and Transport tube containing modified Cary-Blair medium. The test is performed utilizing real-time polymerase chain reaction (PCR) for the amplification of specific sequences of target DNA. The test utilizes fluorogenic sequence-specific hybridization probes for detection of the amplified DNA.

This test is intended for use, in conjunction with clinical presentation, laboratory findings, and epidemiological information, as an aid in the differential diagnosis of Salmonella, Shigella/EIEC, Campylobacter, Shiga toxin-producing E. coli (STEC), Plesiomonas shigelloides, Vibrio spp. (V. vulnificus, V. parahaemolyticus, and V. cholerae), Enterotoxigenic Escherichia coli (ETEC) LT/ST, and Yersinia enterocolitica. Results of this test should not be used as the sole basis for diagnosis, treatment, or other patient management decisions. Positive results do not rule out co-infection with other organisms that are not detected by this test and may not be the sole or definitive cause of patient illness. Negative results in the setting of clinical illness compatible with gastroenteritis may be due to infection by pathogens that are not detected by this test or non-infectious causes such as ulcerative colitis, irritable bowel syndrome, or Crohn’s disease.

Enteric Bacterial Panel Diluent for BD COR™ System

The Enteric Bacterial Panel Diluent for BD COR™ System is intended to be used in clinical settings according to instructions provided for aliquoting into Molecular Aliquot Tubes by the BD COR™ System. The Enteric Bacterial Panel Diluent for BD COR™ System is only for use with BD Fecal Collection and Transport Kit specimens tested on BD COR™ Systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K250358: BD Enteric Bacterial Panel for BD COR System, BD Enteric Bacterial Panel plus for BD COR System, and Enteric Bacterial Panel Diluent for BD COR System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K250358

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026