510(k) Report

510(k) · Cleared

Cleared

ACL AcuStar

K170314510(k) SpecialCleared Mar 3, 201730-day reviewClass II21 CFR 864.5425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Instrumentation Laboratory CO · JPA System, Multipurpose For In Vitro Coagulation Studies

Cleared on Mar 3, 2017 as substantially equivalent to K083518 (Instrumentation Laboratory CO, 2009) after a 30-day review. Its family tree reaches back 6 generations to 1986.

Decided
Mar 3, 2017
Review
30 days
Class
Class II
Product code
JPA
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K862156 (1986). 13 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK862156 Asserachrom D-DI KitAmerican Bioproducts Co. · 1986
  2. 5 generations backK973819 Vidas D-Dimer (DD) AssayBiomerieux Vitek, Inc. · 1998
  3. 4 generations backK020810 Vidas D-Dimer New (DD2) Assay Model#30 442bioMerieux, Inc. · 2002
  4. 3 generations backK040882 Vidas D-Dimer Exclusion Assay, Model 30 442bioMerieux, Inc. · 2004
  5. 2 generations backK070927 Hemosil D-Dimer HSInstrumentation Laboratory CO · 2007
  6. 1 generation backK083518 Acl Acustar, Hemosil Acustar D-Dimer, Hemosil Acustar D-Dimer ControlsInstrumentation Laboratory CO · 2009
  7. This deviceK170314 ACL AcuStarInstrumentation Laboratory CO · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K862156Asserachrom D-DI KitAmerican Bioproducts Co.1986—
−5K973819Vidas D-Dimer (DD) AssayBiomerieux Vitek, Inc.1998—
−4K020810Vidas D-Dimer New (DD2) Assay Model#30 442bioMerieux, Inc.2002—
−3K040882Vidas D-Dimer Exclusion Assay, Model 30 442bioMerieux, Inc.2004—
−2K070927Hemosil D-Dimer HSInstrumentation Laboratory CO2007—
−1K083518Acl Acustar, Hemosil Acustar D-Dimer, Hemosil Acustar D-Dimer ControlsInstrumentation Laboratory CO2009—
0 (this device)K170314ACL AcuStarInstrumentation Laboratory CO2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199510
199710
200010
200410
200710
200810
FIG. 1 — Lineage of K170314, 1986–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JPA device

  1. #1 K243858 TEG 6s Hemostasis System Citrated: K, KH, RT…score 12.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083518Acl Acustar, Hemosil Acustar D-Dimer, Hemosil Acustar D-Dimer Controls
Summary page 4
…Panel: Hematology (81) Product Code: JPA Predicate Device ACL AcuStar: K083518 Indications for Use / The ACL AcuStar is an automated immunoassay analyzer designed Intended Use…
Instrumentation Laboratory CO2009—

Also cleared against K083518: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 4 companies; a new generation was cleared every 4.6 years on median.
  • 3 of the 13 ancestors have a recall of any class.
  • 1 other device also cites its predicate K083518.

How does its category compare?

All JPA devices

JPA System, Multipurpose For In Vitro Coagulation Studies: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · JPA

3in 2025

2007: 12008: 22009: 62010: 12011: 12013: 12015: 22016: 62017: 42018: 12019: 32021: 12022: 12023: 32024: 12025: 32026 (partial year): 1
2007high 6 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JPA

30in 2025

2009: 91 days median2016: 114 days median2017: 117 days median2019: 175 days median2023: 506 days median2025: 30 days median
2007high 506 (2023) · low 30 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JPA

1in 2020

2007: 12010: 62011: 42012: 12016: 32020: 12026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JPA

11in 2025

2007: 1,7442008: 9182009: 1,3632010: 7272011: 1612012: 522013: 432014: 482015: 452016: 62017: 152018: 392019: 272020: 182021: 72022: 92023: 112024: 82025: 11
2007high 1,744 (2007) · low 6 (2016)2025

MAUDE reports naming product code JPA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—11,744
20082—0918
200969101,363
20101—6727
20111—4161
20120—152
20131—043
20140—048
20152—045
2016611436
20174117015
20181—039
20193175027
20200—118
20211—07
20221—09
20233506011
20241—08
2025330011
20261—1—

What is it indicated for?

Automated immunoassay analyzer designed specifically for in vitro diagnostic use in a clinical laboratory. The assay analysis is based on chemiluminescent technology. The system provides results for both direct measurements and calculated parameters.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K170314: ACL AcuStar.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K170314

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026