510(k) Report

510(k) · Cleared

Cleared

Firebow Wire Torque Assist Device

K170684510(k) TraditionalCleared Jun 29, 2017114-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vesatek, LLC · DQX Wire, Guide, Catheter

Cleared on Jun 29, 2017 as substantially equivalent to K141054 (Distal Access, LLC, 2014) and 1 other predicate after a 114-day review. Its family tree reaches back 8 generations to 1985. 1 of the 19 devices in its family, counting itself, has a Class I recall. 1 later device descends from it.

Decided
Jun 29, 2017
Review
114 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K854261 (1985). 17 ancestors in all. 1 later device descends from it, 1 citing it directly. 1 of the 19 devices in this family, counting this one, has a Class I recall.

  1. Root · 8 generations backK854261 Advanced Cardiovascular Systems Hemostatic ValvesAdvanced Cardiovascular Systems, Inc. · 1985 · Recalled
  2. 7 generations backK991102 Copilot Bleedback Control Valve, Model 1003331Guidant Corp. · 1999 · Recalled
  3. 6 generations backK042060 Easypass US Y-Connector Hemostatic ValveMillimed A/S · 2004
  4. 5 generations backK052381 Guardian Hemostasis Valve with Guidewire IntroducerZerusa Limited · 2005
  5. 4 generations backK073620 Guardian Hemostasis ValveZerusa Limited · 2008
  6. 3 generations backK092711 Guardian II Hemostasis ValveZerusa Limited · 2009 · Recalled (Class I)
  7. 2 generations backK100093 Vsi Torque DeviceVascular Solutions, Inc. · 2010
  8. 1 generation backK141054 Distal Access Torque DeviceDistal Access, LLC · 2014
  9. This deviceK170684 Firebow Wire Torque Assist DeviceVesatek, LLC · 2017
  10. Descendant · cites it directly · 0 of its ownK200120 LiteSaber Wire Torque Assist DeviceVesatek, LLC · 2020

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K200120LiteSaber Wire Torque Assist DeviceVesatek, LLC · 2020 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K854261Advanced Cardiovascular Systems Hemostatic ValvesAdvanced Cardiovascular Systems, Inc.19852
−7K991102Copilot Bleedback Control Valve, Model 1003331Guidant Corp.19991
−6K042060Easypass US Y-Connector Hemostatic ValveMillimed A/S2004—
−5K052381Guardian Hemostasis Valve with Guidewire IntroducerZerusa Limited2005—
−4K073620Guardian Hemostasis ValveZerusa Limited2008—
−3K092711Guardian II Hemostasis ValveZerusa Limited2009Class I
−2K100093Vsi Torque DeviceVascular Solutions, Inc.2010—
−1K141054Distal Access Torque DeviceDistal Access, LLC2014—
0 (this device)K170684Firebow Wire Torque Assist DeviceVesatek, LLC2017—
+1K200120LiteSaber Wire Torque Assist DeviceVesatek, LLC2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198620
199110
199310
199410
199510
200010
200210
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
FIG. 1 — Lineage of K170684, 1985–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K141054Distal Access Torque Device
Summary page 4
…evice Classification Name: Catheter guide wire (21 CFR 870.1330) Product Code: DQX Predicate Devices: Distal Access Torque Device (K141054) Merit Medical SeaDragon Torque Device (K936032) Device Description: The Firebow Wire Torque Assis…
Distal Access, LLC2014—
*K936032Torque Device
Summary page 4
…oduct Code: DQX Predicate Devices: Distal Access Torque Device (K141054) Merit Medical SeaDragon Torque Device (K936032) Device Description: The Firebow Wire Torque Assist Device is an electrically driven device that delivers a controlled, predicta…
Merit Medical Systems, Inc.1994—

Also cleared against K141054: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K200120LiteSaber Wire Torque Assist DeviceVesatek, LLC20200

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K092711Guardian II Hemostasis ValveZerusa Limited · 2009 · 3 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 32 years and passes through 7 companies; a new generation was cleared every 2.6 years on median.
  • 4 of the 17 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K200120 (Vesatek, LLC, 2020) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K141054.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

The Firebow Wire Torque Assist Device is used to maneuver guidewires in the coronary and peripheral vasculature during interventional or diagnostic procedures. The Firebow Wire Torque Assist Device is not intended for use in the neurovasculature.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K170684: Firebow Wire Torque Assist Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K170684

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026