510(k) Report

510(k) · Cleared

Cleared

Reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) and STEADY PRO range

K171040510(k) TraditionalCleared Jul 31, 2017116-day reviewClass II21 CFR 892.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Koelis · ITX Transducer, Ultrasonic, Diagnostic

Cleared on Jul 31, 2017 as substantially equivalent to K093713 (Civco Medical Instruments, 2010) and 1 other predicate after a 116-day review. Its family tree reaches back 6 generations to 1985.

Decided
Jul 31, 2017
Review
116 days
Class
Class II
Product code
ITX
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K850478 (1985). 15 ancestors in all, the oldest K850571 (1985). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2013: 1 other ancestor2003: 1 other ancestor1997: 1 other ancestor1988: 2 other ancestors1992: 1 other ancestor1991: 1 other ancestor1985: 1 other ancestor1986: 1 other ancestorK850478 · PLUS 1 · Dymax Corp · 1985K993624 · Site-Rite 3 Ultrasound System · Dymax Corp · 1999K032135 · Site-Rite IV Ultrasound System · Dymax Corp · 2003K052517 · Site-Rite 5 Ultrasound System · C.R. Bard, Inc. · 2005K071204 · Site-Rite 6 Ultrasound System, Model Site-Rite 6 · C.R. Bard, Inc. · 2007K093713 · Ultrasound General Purpose Guidance System · Civco Medical Instruments · 2010 · recalled1985199019952000200520102015
  1. Root · 6 generations backK850478 PLUS 1Dymax Corp · 1985
  2. 5 generations backK993624 Site-Rite 3 Ultrasound SystemDymax Corp · 1999
  3. 4 generations backK032135 Site-Rite IV Ultrasound SystemDymax Corp · 2003
  4. 3 generations backK052517 Site-Rite 5 Ultrasound SystemC.R. Bard, Inc. · 2005
  5. 2 generations backK071204 Site-Rite 6 Ultrasound System, Model Site-Rite 6C.R. Bard, Inc. · 2007
  6. 1 generation backK093713 Ultrasound General Purpose Guidance SystemCivco Medical Instruments · 2010 · Recalled
  7. This deviceK171040 Reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and…Koelis · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K850478PLUS 1Dymax Corp1985—
−5K993624Site-Rite 3 Ultrasound SystemDymax Corp1999—
−4K032135Site-Rite IV Ultrasound SystemDymax Corp2003—
−3K052517Site-Rite 5 Ultrasound SystemC.R. Bard, Inc.2005—
−2K071204Site-Rite 6 Ultrasound System, Model Site-Rite 6C.R. Bard, Inc.2007—
−1K093713Ultrasound General Purpose Guidance SystemCivco Medical Instruments20107
0 (this device)K171040Reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD…Koelis2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198610
198820
199110
199210
199710
200310
201310
FIG. 1 — Lineage of K171040, 1985–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITX device

  1. #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K093713Ultrasound General Purpose Guidance System
Summary page 4
…E range, NAIL range, CON-LEAD range and LIN-LEAD range) and STEADY PRO range are substantially equivalent to: 510(k) Number Device Name K093713 Ultrasound General Purpose Guidance System K131161 A…
Civco Medical Instruments20107
*K131161EX3 Stepper, Classic Stepper, Multi-Purpose Workstation Stepper; Micro-Touch…
Summary page 4
…ally equivalent to: 510(k) Number Device Name K093713 Ultrasound General Purpose Guidance System K131161 AccuCARETM product line Intended Use: The reusable guides ranges (PERINE range, NAIL range…
CIVCO Medical Instruments Co., Inc.2013—

Also cleared against K093713: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 4 companies; a new generation was cleared every 3.7 years on median.
  • 2 of the 15 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K093713.

How does its category compare?

All ITX devices

ITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · ITX

4in 2025

2007: 102008: 122009: 172010: 102011: 102012: 72013: 32014: 42015: 12016: 42017: 62018: 22019: 12020: 32021: 32022: 22023: 62024: 32025: 42026 (partial year): 6
2007high 17 (2009) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITX

126in 2025

2007: 26 days median2008: 73 days median2009: 28 days median2010: 42 days median2011: 16 days median2012: 25 days median2013: 105 days median2014: 41 days median2016: 151 days median2017: 110 days median2020: 120 days median2021: 139 days median2023: 213 days median2024: 81 days median2025: 126 days median2026 (partial year): 158 days median
2007high 213 (2023) · low 16 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITX

2in 2025

2008: 42009: 42010: 42011: 12012: 12014: 12015: 52017: 12018: 152020: 32021: 10, 10 Class I2022: 62023: 12024: 12025: 2
2007high 15 (2018) · low 0 (2007)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · ITX

571in 2025

2007: 162008: 392009: 232010: 302011: 342012: 292013: 382014: 432015: 1832016: 2692017: 4122018: 1302019: 1192020: 1162021: 1462022: 872023: 1382024: 9882025: 571
2007high 988 (2024) · low 16 (2007)2025

MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071026016
20081273439
20091728423
20101042430
20111016134
2012725129
20133105038
2014441143
20151—5183
201641510269
201761101412
20182—15130
20191—0119
202031203116
2021313910 (10)146
20222—687
202362131138
20243811988
202541262571
202661580—

What is it indicated for?

The reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) and STEADY PRO range are indicated for diagnosis and treatment for ultrasound-guided interventions. I. Reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) The reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) are indicated for guiding needles during ultrasound-guided interventions for diagnosis and…

Read the full statement (150 words)

The reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) and STEADY PRO range are indicated for diagnosis and treatment for ultrasound-guided interventions.

I. Reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range)

The reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) are indicated for guiding needles during ultrasound-guided interventions for diagnosis and treatment.

l.a. CON-LEAD range and LIN-LEAD range

The guides from CON-LEAD range and LIN-LEAD range are indicated for guiding needles during percutaneous ultrasound-guided interventions for diagnosis and treatment.

1.b. PERINE range

The guides from the PERINE range are indicated for guiding needles during percutaneous ultrasound-guided interventions for diagnosis and treatment on adult males.

2. Steady Pro range

The Steady Pro range provides physician a tool for performing ultrasound-guided interventions with the use of an endocavity ultrasound transducer for adult males requiring prostate biopsy mapping and cancer treatment.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K171040: Reusable guides ranges (PERINE range, NAIL range, CON-LEAD range and LIN-LEAD range) and STEADY PRO range.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K171040

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026