510(k) Report

510(k) · Cleared

Cleared

BH Sterilization Pouch

K172280510(k) TraditionalCleared Aug 3, 2018371-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bh Medical Products Co., Ltd. · FRG Wrap, Sterilization

Cleared on Aug 3, 2018 as substantially equivalent to K070428 (A.R. Medicom, Inc., 2007) after a 371-day review. Its family tree reaches back 4 generations to 1999. 1 later device descends from it.

Decided
Aug 3, 2018
Review
371 days
Class
Class II
Product code
FRG
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K990567 (1999). 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backK990567 Global Healthcare Self-Sealing Sterilization PouchGlobal Healthcare, Inc. · 1999
  2. 3 generations backK993764 Medipack See-Through Seal Sterilization PouchMedipack Medical Packaging Mfg. Co. · 1999
  3. 2 generations backK051242 Winner Self Seal Sterilization PouchWinner Medical (Usa), Inc. · 2005
  4. 1 generation backK070428 Medicom Self-Sealing Sterilization PouchA.R. Medicom, Inc. · 2007
  5. This deviceK172280 BH Sterilization PouchBh Medical Products Co., Ltd. · 2018
  6. Descendant · cites it directly · 0 of its ownK191131 Solidence MultipocketsSolidence Surgical Corporation · 2022

Most influential descendants

Showing 1 of 1 · See all
  • K191131Solidence MultipocketsSolidence Surgical Corporation · 2022 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K990567Global Healthcare Self-Sealing Sterilization PouchGlobal Healthcare, Inc.1999—
−3K993764Medipack See-Through Seal Sterilization PouchMedipack Medical Packaging Mfg. Co.1999—
−2K051242Winner Self Seal Sterilization PouchWinner Medical (Usa), Inc.2005—
−1K070428Medicom Self-Sealing Sterilization PouchA.R. Medicom, Inc.2007—
0 (this device)K172280BH Sterilization PouchBh Medical Products Co., Ltd.2018—
+1K191131Solidence MultipocketsSolidence Surgical Corporation2022—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
FIG. 1 — Lineage of K172280, 1999–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRG device

  1. #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070428Medicom Self-Sealing Sterilization Pouch
Summary page 4
…21CFR 880.2800 Product Code: 2) JOJ Predicate Device to BH Sterilization Pouch: Trade Name: Medicom Self Sealing Sterilization Pouch 510(k) Number: K070428 Manufactured by: A.R. Medicom Inc. 1200 55th Avenue, Lachine, Quebec, H8T 3J8, Canada Device Description: The…
A.R. Medicom, Inc.2007—

Also cleared against K070428: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191131Solidence MultipocketsSolidence Surgical Corporation20220

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 5 companies; a new generation was cleared every 6.0 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K191131 (Solidence Surgical Corporation, 2022) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K070428.

How does its category compare?

All FRG devices

FRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · FRG

9in 2025

2007: 32008: 22009: 42010: 42011: 62012: 102013: 62014: 82015: 122016: 92017: 92018: 52019: 92020: 52021: 42022: 92023: 92024: 112025: 92026 (partial year): 4
2007high 12 (2015) · low 2 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRG

151in 2025

2007: 182 days median2009: 171 days median2010: 213 days median2011: 110 days median2012: 133 days median2013: 146 days median2014: 177 days median2015: 196 days median2016: 131 days median2017: 260 days median2018: 150 days median2019: 258 days median2020: 122 days median2021: 170 days median2022: 217 days median2023: 230 days median2024: 182 days median2025: 151 days median2026 (partial year): 247 days median
2007high 260 (2017) · low 110 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRG

2in 2022

2013: 22017: 292020: 142022: 2
2007high 29 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRG

18in 2025

2007: 12008: 22009: 22011: 122012: 42013: 52014: 132015: 92016: 202017: 72018: 222019: 102020: 212021: 92022: 42023: 132024: 212025: 18
2007high 22 (2018) · low 0 (2010)2025

MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007318201
20082—02
2009417102
2010421300
20116110012
20121013304
2013614625
20148177013
20151219609
20169131020
20179260297
20185150022
20199258010
202051221421
2021417009
2022921724
20239230013
202411182021
20259151018
202642470—

What is it indicated for?

The BH sterilization pouch is intended to provide dentists with an effective method to enclose devices intended for sterilization in steam auto claves. The recommended pre-vacuum steam sterilization cycle parameters are 4 minutes at 132°C (270°F). The sterilization pouch maintains the enclosed devices up until 180 days post sterilization. Lastly, the pouch's external chemical ink indicators are designed to indicate to the user that the pouch has undergone a steam sterilization process. Only one instrument can be sterilized in one pouch and only instruments that are be metal, hinged, or knurled can be sterilized in the pouch.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172280: BH Sterilization Pouch.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K172280

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026