510(k) Report

510(k) · Cleared

Cleared

Cervage

K172568510(k) TraditionalCleared May 4, 2018252-day reviewClass II21 CFR 888.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Precifit Medical, Ltd. · ODP Intervertebral Fusion Device With Bone Graft, Cervical

Cleared on May 4, 2018 as substantially equivalent to K133653 (Medtronic Sofamor Danek USA, Inc., 2014) and 1 other predicate after a 252-day review. Its family tree reaches back 14 generations to 2001. 1 later device descends from it.

Decided
May 4, 2018
Review
252 days
Class
Class II
Product code
ODP
Recalls
None
Predicates
2

Its longest line of descent runs back 14 generations to K003155 (2001). 93 ancestors in all, the oldest K792352 (1979). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2014: 1 other ancestor2013: 1 other ancestor2011: 1 other ancestor2010: 2 other ancestors2009: 6 other ancestors2008: 10 other ancestors2005: 4 other ancestors2004: 14 other ancestors2003: 9 other ancestors2002: 6 other ancestors2001: 8 other ancestors1999: 2 other ancestors1996: 2 other ancestors2007: 5 other ancestors2006: 3 other ancestors2000: 1 other ancestor1984: 1 other ancestor1998: 1 other ancestor1980: 1 other ancestor1979: 1 other ancestor2018: 1 descendant clearedReference device: K171630 · LumFuse-TP · Precifit Medical, Ltd. · 2017K003155 · Vertebral Body Replacement · Osteotech, Inc. · 2001K012254 · VBR · Osteotech, Inc. · 2001×3: 3 generations cleared close together, K021791 (2002), K023570 (2002), K030601 (2003) ×3: 3 generations cleared close together, K040536 (2004), K041556 (2004), K043561 (2004) ×3: 3 generations cleared close together, K060719 (2006), K062133 (2006), K070173 (2007) K073285 · Peek Prevail Cervical Interbody Device · Medtronic Sofamor Danek USA, Inc. · 2008K100214 · Cornerstone PSR Cervical Interbody Fusion Device · Medtronic Sofamor Danek · 2010K112444 · Anatomic Peek Cervical Fusion System · Medtronic Sofamor Danck USA, Inc. · 201119801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 5 other ancestors3 generations back: 17 other ancestors4 generations back: 15 other ancestors5 generations back: 12 other ancestors6 generations back: 14 other ancestors7 generations back: 10 other ancestors8 generations back: 4 other ancestors9 generations back: 1 other ancestor 1 generation forward: 1 descendant K112444 · Anatomic Peek Cervical Fusion System · Medtronic Sofamor Danck USA, Inc. · 2011K100214 · Cornerstone PSR Cervical Interbody Fusion Device · Medtronic Sofamor Danek · 2010K073285 · Peek Prevail Cervical Interbody Device · Medtronic Sofamor Danek USA, Inc. · 2008K070173 · Verte-Stack Spinal System · Medtronic Sofamor Danek, Inc. · 2007K062133 · Modification to Verte-Stack Spinal System · Medtronic Spinal and Biologics Div · 2006K060719 · Modification to Verte-Stack Spinal System · Medtronic Sofamor Danek · 2006K043561 · Modification to Verte-Stack Spinal System · Medtronic Sofamor Danek · 2004K041556 · Modification to Verte-Stack Spinal System · Medtronic Sofamor Danek · 2004K040536 · Modification to Verte-Stack Spinal System · Medtronic Sofamor Danek · 2004K030601 · Verte-Stack Spinal System · Medtronic Sofamor Danek · 2003K023570 · Modification to Verte-Stack Spinal System · Medtronic Sofamor Danek · 2002K021791 · Verte-Stack Spinal System · Medtronic Sofamor Danek · 2002K012254 · VBR · Osteotech, Inc. · 2001K003155 · Vertebral Body Replacement · Osteotech, Inc. · 2001−10−50
  1. Root · 14 generations backK003155 Vertebral Body ReplacementOsteotech, Inc. · 2001
  2. 10 generations between
  3. 3 generations backK073285 Peek Prevail Cervical Interbody DeviceMedtronic Sofamor Danek USA, Inc. · 2008
  4. 2 generations backK100214 Cornerstone PSR Cervical Interbody Fusion DeviceMedtronic Sofamor Danek · 2010
  5. 1 generation backK112444 Anatomic Peek Cervical Fusion SystemMedtronic Sofamor Danck USA, Inc. · 2011
  6. This deviceK172568 CervagePrecifit Medical, Ltd. · 2018
  7. Descendant · cites it directly · 0 of its ownK173189 Lumfuse TPPrecifit Medical, Ltd. · 2018
Show all 14 generations
  1. Root · 14 generations backK003155 Vertebral Body ReplacementOsteotech, Inc. · 2001
  2. 13 generations backK012254 VBROsteotech, Inc. · 2001
  3. 12 generations backK021791 Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2002
  4. 11 generations backK023570 Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2002
  5. 10 generations backK030601 Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2003
  6. 9 generations backK040536 Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2004
  7. 8 generations backK041556 Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2004
  8. 7 generations backK043561 Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2004
  9. 6 generations backK060719 Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek · 2006
  10. 5 generations backK062133 Modification to Verte-Stack Spinal SystemMedtronic Spinal and Biologics Div · 2006
  11. 4 generations backK070173 Verte-Stack Spinal SystemMedtronic Sofamor Danek, Inc. · 2007
  12. 3 generations backK073285 Peek Prevail Cervical Interbody DeviceMedtronic Sofamor Danek USA, Inc. · 2008
  13. 2 generations backK100214 Cornerstone PSR Cervical Interbody Fusion DeviceMedtronic Sofamor Danek · 2010
  14. 1 generation backK112444 Anatomic Peek Cervical Fusion SystemMedtronic Sofamor Danck USA, Inc. · 2011
  15. This deviceK172568 CervagePrecifit Medical, Ltd. · 2018

Most influential descendants

Showing 1 of 1 · See all
  • K173189Lumfuse TPPrecifit Medical, Ltd. · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K003155Vertebral Body ReplacementOsteotech, Inc.2001—
−13K012254VBROsteotech, Inc.2001—
−12K021791Verte-Stack Spinal SystemMedtronic Sofamor Danek2002—
−11K023570Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek2002—
−10K030601Verte-Stack Spinal SystemMedtronic Sofamor Danek2003—
−9K040536Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek2004—
−8K041556Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek2004—
−7K043561Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek2004—
−6K060719Modification to Verte-Stack Spinal SystemMedtronic Sofamor Danek2006—
−5K062133Modification to Verte-Stack Spinal SystemMedtronic Spinal and Biologics Div2006—
−4K070173Verte-Stack Spinal SystemMedtronic Sofamor Danek, Inc.2007—
−3K073285Peek Prevail Cervical Interbody DeviceMedtronic Sofamor Danek USA, Inc.2008—
−2K100214Cornerstone PSR Cervical Interbody Fusion DeviceMedtronic Sofamor Danek2010—
−1K112444Anatomic Peek Cervical Fusion SystemMedtronic Sofamor Danck USA, Inc.2011—
0 (this device)K172568CervagePrecifit Medical, Ltd.2018—
+1K173189Lumfuse TPPrecifit Medical, Ltd.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198010
198410
199620
199810
199920
200010
200180
200260
200390
2004140
200540
200630
200750
2008100
200960
201020
201110
201310
201410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
FIG. 1 — Lineage of K172568, 2001–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODP device

  1. #1 K222276 CONDUIT Cages; FIBERGRAFT BG Puttyscore 53.4 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K133653Anatomic Peek PTC Cervical Fusion System
Summary page 4
…Primary: Medtronic® ANATOMIC PEEK PTC CERVICAL FUSION SYSTEM (K133653); Additional: Medtronic® ANATOMIC PEEK CERVICAL…
Medtronic Sofamor Danek USA, Inc.2014—
*K112444Anatomic Peek Cervical Fusion System
Summary page 4
…); Additional: Medtronic® ANATOMIC PEEK CERVICAL FUSION SYSTEM (K112444) Reference: Precifit Medical LUMFUSE-TP (K171630) (a)(4) Device Description:…
Medtronic Sofamor Danck USA, Inc.2011—
†K171630LumFuse-TPPrecifit Medical, Ltd.2017—

Also cleared against K133653: 4 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173189Lumfuse TPPrecifit Medical, Ltd.20180

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 7 companies; a new generation was cleared every 10 months on median.
  • 6 of the 93 ancestors have a recall of any class.
  • Of its descendants, K173189 (Precifit Medical, Ltd., 2018) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K133653.

How does its category compare?

All ODP devices

ODP Intervertebral Fusion Device With Bone Graft, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · ODP

11in 2025

2008: 82009: 122010: 92011: 252012: 172013: 182014: 262015: 242016: 172017: 332018: 252019: 222020: 142021: 182022: 122023: 342024: 102025: 112026 (partial year): 19
2007high 34 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODP

87in 2025

2008: 89 days median2009: 127 days median2010: 151 days median2011: 113 days median2012: 93 days median2013: 187 days median2014: 118 days median2015: 180 days median2016: 112 days median2017: 104 days median2018: 133 days median2019: 92 days median2020: 89 days median2021: 121 days median2022: 92 days median2023: 165 days median2024: 76 days median2025: 87 days median2026 (partial year): 117 days median
2007high 187 (2013) · low 76 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODP

2in 2025

2009: 12011: 12013: 12020: 12025: 2
2007high 2 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODP

57in 2025

2008: 22009: 212010: 542011: 382012: 922013: 782014: 432015: 512016: 372017: 392018: 512019: 1412020: 862021: 1612022: 502023: 362024: 552025: 57
2007high 161 (2021) · low 0 (2007)2025

MAUDE reports naming product code ODP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
200888902
200912127121
20109151054
201125113138
20121793092
201318187178
201426118043
201524180051
201617112037
201733104039
201825133051
201922920141
20201489186
2021181210161
20221292050
202334165036
20241076055
20251187257
2026191170—

What is it indicated for?

The Cervage cage is indicated for cervical interbody fusion procedures in skeletally mature patients with cervical disc disease at one level from the C2-C3 disc to the C7-T1 disc. Cervical disc disease is defined as intractable radiculopathy and/or myelopathy with herniated disc and/or osteophyte formation on posterior vertebral endplates producing symptomatic nerve root and/or spinal cord compression confirmed by radiographic studies. This device is to…

Read the full statement (119 words)

The Cervage cage is indicated for cervical interbody fusion procedures in skeletally mature patients with cervical disc disease at one level from the C2-C3 disc to the C7-T1 disc. Cervical disc disease is defined as intractable radiculopathy and/or myelopathy with herniated disc and/or osteophyte formation on posterior vertebral endplates producing symptomatic nerve root and/or spinal cord compression confirmed by radiographic studies. This device is to be used in patients who have had six weeks on non-operative treatment. The Cervage cage is to be used with supplemental fixation. The Cervage cage is also required to be used with autograft and/or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft and is to be implanted via an open, anterior approach.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172568: Cervage.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172568

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026