510(k) Report

510(k) · Cleared

Cleared

Materialise PKA Guide System

K172650510(k) TraditionalCleared Nov 20, 201776-day reviewClass II21 CFR 888.3520

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Materialise NV · HSX Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer

Cleared on Nov 20, 2017 as substantially equivalent to K112301 (Materialise NV, 2012) and 1 other predicate after a 76-day review. Its family tree reaches back 9 generations to 1993. 6 later devices descend from it.

Decided
Nov 20, 2017
Review
76 days
Class
Class II
Product code
HSX
Recalls
None
Predicates
2

Its longest line of descent runs back 9 generations to K924630 (1993). 18 ancestors in all, the oldest K880155 (1988). 6 later devices descend from it, 1 citing it directly.

  1. Root · 9 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
  2. 5 generations between
  3. 3 generations backK133162 Zimmer Patient Specific Instruments System, Zimmer Patient Specific…Materialise NV · 2014
  4. 2 generations backK150928 Materialise TKA Guide System, Materialise TKA Planner, Materialise…Materialise NV · 2015
  5. 1 generation backK162273 Materialise TKA Guide SystemMaterialise NV · 2016
  6. This deviceK172650 Materialise PKA Guide SystemMaterialise NV · 2017
  7. Descendant · cites it directly · 5 of its ownK173970 Materialise PKA Guide SystemMaterialise NV · 2018
  8. Descendant · 2 generations on · 3 of its ownK211512 VISIONAIRE UK Patient Matched Cutting GuidesSmith & Nephew, Inc. · 2021
  9. Descendant · 3 generations on · 2 of its ownK240113 CORIOGRAPH Knee Pre-Op PlanSmith & Nephew, Inc. · 2024
  10. Descendant · 4 generations on · 1 of its ownK242272 CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc. · 2024
  11. Descendant · 5 generations on · 0 of its ownK250921 CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc. · 2025
Show all 9 generations
  1. Root · 9 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
  2. 8 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
  3. 7 generations backK033849 Simplant SystemMaterialise NV · 2004
  4. 6 generations backK073449 SurgicaseMaterialise NV · 2008
  5. 5 generations backK102795 Signature Planner; Signature GuidesMaterialise NV · 2011 · Recalled
  6. 4 generations backK121640 Zimmer Patient Specific Instruments SystemMaterialise NV · 2012 · Recalled
  7. 3 generations backK133162 Zimmer Patient Specific Instruments System, Zimmer Patient Specific…Materialise NV · 2014
  8. 2 generations backK150928 Materialise TKA Guide System, Materialise TKA Planner, Materialise…Materialise NV · 2015
  9. 1 generation backK162273 Materialise TKA Guide SystemMaterialise NV · 2016
  10. This deviceK172650 Materialise PKA Guide SystemMaterialise NV · 2017

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2018: 12020: 12021: 12024: 22025: 1
2018high 2 (2024) · low 0 (2019)2026

Most influential descendants

Showing 5 of 6 · See all
  • K173970Materialise PKA Guide SystemMaterialise NV · 2018 · cites it directly5descendants
  • K211512VISIONAIRE UK Patient Matched Cutting GuidesSmith & Nephew, Inc. · 2021 · 2 generations on3descendants
  • K240113CORIOGRAPH Knee Pre-Op PlanSmith & Nephew, Inc. · 2024 · 3 generations on2descendants
  • K242272CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc. · 2024 · 4 generations on1descendant
  • K250921CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc. · 2025 · 5 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K924630Surgicad (TM) View (TM)Surgicad Corp.1993—
−8K970617CT-Modeller SystemMaterialise NV1997—
−7K033849Simplant SystemMaterialise NV2004—
−6K073449SurgicaseMaterialise NV2008—
−5K102795Signature Planner; Signature GuidesMaterialise NV20114
−4K121640Zimmer Patient Specific Instruments SystemMaterialise NV20121
−3K133162Zimmer Patient Specific Instruments System, Zimmer Patient Specific…Materialise NV2014—
−2K150928Materialise TKA Guide System, Materialise TKA Planner, Materialise TKA GuidesMaterialise NV2015—
−1K162273Materialise TKA Guide SystemMaterialise NV2016—
0 (this device)K172650Materialise PKA Guide SystemMaterialise NV2017—
+1K173970Materialise PKA Guide SystemMaterialise NV2018—
+2K211512VISIONAIRE UK Patient Matched Cutting GuidesSmith & Nephew, Inc.2021—
+3K240113CORIOGRAPH Knee Pre-Op PlanSmith & Nephew, Inc.2024—
+4K242272CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc.2024—
+5K250921CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199310
200110
200410
200810
201010
201120
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
202010
202110
202420
202510
FIG. 1 — Lineage of K172650, 1993–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HSX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HSX device

  1. #1 K261609 Freedom Partial Knee Systemscore 15.1 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112301Zimmer Patient Specific Instruments Planner
Summary page 5
…model name Zimmer Patient Specific Instruments System 3.0 f 510(k) number K112301 Decision date January 6th, 2012 Classification product code…
Materialise NV2012—
*K162273Materialise TKA Guide System
Summary page 5
…valence is claimed: Trade or proprietary or model name Materialise TKA Guide System 510(k) number K162273 Decision date November 7th, 2016 Classification product code…
Materialise NV2016—
†K161559Kuvia3D4qimaging, LLC Dba Qmetrics2016—

What descends from it? (6)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173970Materialise PKA Guide SystemMaterialise NV20185

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 2 companies; a new generation was cleared every 1.8 years on median.
  • 6 of the 18 ancestors have a recall of any class.
  • Of its descendants, K173970 (Materialise NV, 2018) has gone furthest, with 5 descendants of its own.

How does its category compare?

All HSX devices

HSX Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · HSX

4in 2025

2007: 62008: 42009: 22010: 32011: 12012: 52013: 22015: 12016: 32017: 52018: 22019: 72020: 42021: 72022: 22023: 12024: 42025: 42026 (partial year): 2
2007high 7 (2019) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HSX

59in 2025

2007: 33 days median2008: 102 days median2010: 74 days median2012: 88 days median2016: 147 days median2017: 160 days median2019: 90 days median2020: 40 days median2021: 81 days median2024: 133 days median2025: 59 days median
2007high 160 (2017) · low 33 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HSX

2in 2020

2009: 492013: 12016: 12017: 42020: 2
2007high 49 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HSX

175in 2025

2007: 62008: 42009: 212010: 582011: 1142012: 832013: 792014: 662015: 572016: 1072017: 1132018: 1592019: 1772020: 2732021: 2402022: 2572023: 2312024: 1722025: 175
2007high 273 (2020) · low 4 (2008)2025

MAUDE reports naming product code HSX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200763306
2008410204
20092—4921
2010374058
20111—0114
2012588083
20132—179
20140—066
20151—057
201631471107
201751604113
20182—0159
20197900177
20204402273
20217810240
20222—0257
20231—0231
202441330172
20254590175
20262—0—

What is it indicated for?

The Materialise PKA Guide System is intended to be used as a surgical instrument to assist in the positioning of Partial Knee Replacement components intra-operatively and in guiding the marking of bone before cutting and to guide cutting of the bone provided that anatomic landmarks necessary for alignment and positioning of the implant are identifiable on patient imaging scans.

The Materialise PKA Guide System is to be used with ZUK UNI, JOURNEY™ UNI, JOURNEY II UNI, JZ (Hybrid) UNI knee systems prostheses families only.

The Materialise PKA Guides are intended for single use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172650: Materialise PKA Guide System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172650

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026