510(k) · Cleared
ClearedMimics inPrint
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Materialise NV · LLZ System, Image Processing, Radiological
Cleared on Mar 21, 2018 as substantially equivalent to K073468 (Materialise NV, 2008) after a 119-day review. Its family tree reaches back 4 generations to 1993. 13 later devices descend from it.
- Decided
- Mar 21, 2018
- Review
- 119 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K924630 (1993). 5 ancestors in all, the oldest K924810 (1993). 13 later devices descend from it, 4 citing it directly.
- Root · 4 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
- 3 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
- 2 generations backK033849 Simplant SystemMaterialise NV · 2004
- 1 generation backK073468 MimicsMaterialise NV · 2008
- This deviceK173619 Mimics inPrintMaterialise NV · 2018
- Descendant · cites it directly · 4 of its ownK221511 Axial3D Cloud Segmentation ServiceAxial Medical Printing Limited · 2022
- Descendant · 2 generations on · 2 of its ownK222745 Axial3D InsightAxial Medical Printing Limited · 2023
- Descendant · cites it directly · 2 of its ownK191026 Medip ProMedical IP Co., Ltd. · 2019
- Descendant · cites it directly · 2 of its ownK190874 Materialise Mimics EnlightMaterialise NV · 2019
- Descendant · 3 generations on · 1 of its ownK232841 Axial3D InsightAxial Medical Printing Limited · 2023
Showing 5 of 13 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 13 · See all- K221511Axial3D Cloud Segmentation ServiceAxial Medical Printing Limited · 2022 · cites it directly4descendants
- K222745Axial3D InsightAxial Medical Printing Limited · 2023 · 2 generations on2descendants
- K191026Medip ProMedical IP Co., Ltd. · 2019 · cites it directly2descendants
- K190874Materialise Mimics EnlightMaterialise NV · 2019 · cites it directly2descendants
- K232841Axial3D InsightAxial Medical Printing Limited · 2023 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K924630 | Surgicad (TM) View (TM) | Surgicad Corp. | 1993 | — |
| −3 | K970617 | CT-Modeller System | Materialise NV | 1997 | — |
| −2 | K033849 | Simplant System | Materialise NV | 2004 | — |
| −1 | K073468 | Mimics | Materialise NV | 2008 | — |
| 0 (this device) | K173619 | Mimics inPrint | Materialise NV | 2018 | — |
| +1 | K221511 | Axial3D Cloud Segmentation Service | Axial Medical Printing Limited | 2022 | — |
| +2 | K222745 | Axial3D Insight | Axial Medical Printing Limited | 2023 | — |
| +1 | K191026 | Medip Pro | Medical IP Co., Ltd. | 2019 | — |
| +1 | K190874 | Materialise Mimics Enlight | Materialise NV | 2019 | — |
| +3 | K232841 | Axial3D Insight | Axial Medical Printing Limited | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2019 | 2 | 0 |
| 2022 | 2 | 0 |
| 2023 | 4 | 0 |
| 2024 | 2 | 0 |
| 2025 | 1 | 0 |
| 2026 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
What descends from it? (13)
See all 134 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 2 companies; a new generation was cleared every 7.1 years on median.
- None of the 5 ancestors has a recall.
- Of its descendants, K221511 (Axial Medical Printing Limited, 2022) has gone furthest, with 4 descendants of its own.
- 8 other devices also cite its predicate K073468.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Mimics inPrint is intended for use as a software interface and image segmentation system for the transfer of DICOM imaging information from a medical scanner to an output file. It is also used as pre-operative software for treatment planning. For this purpose, the Mimics inPrint output file can be used for the fabrication of physical replicas of the output file using traditional or additive manufacturing methods.
The physical replica can be used for diagnostic purposes in the field of orthopedic, maxillofacial and cardiovascular applications. Mimics inPrint should be used in conjunction with other diagnostic tools and expert clinical judgement.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K173619 · printed Nov 6, 2026
Cite this page
510(k) Report. “K173619: Mimics inPrint.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173619
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026